ANALOG 4 CHANNEL OUTPUT

C-Bus Din Rail Mounted Analogue Output Unit, 4 Channel, 240V

Catalogue Number: L5504AMP
ANALOG 4 CHANNEL OUTPUT
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
EU RoHS Directive
Compliant
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
X
Environmental Disclosure
ENVPEP111278EN_V0
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Technical Data Catalogues

  • Technical Leaflet

  • Installation Instruction

  • Product Environmental

  • End of Life Manual

  • Operating Manuals

  • System User Guide

  • Specifications

  • Application Solutions

  • Certificates (MSDS)

  • Corporate Marketing

  • Software - Released

Frequently Asked Questions

hide show

What is part number for 0-10v C BUS DIMMER?

Part number is L5504AMP.

Can C-Bus operate 0-10V light fittings

Yes, it requires a L5504AMP, and must be used in conjunction with a C-Bus system and can dim 0-10V or 1-10V ballasts.

Output Rating - Sinking: 15mA at Vout = 0V, 8mA at Vout = 10V, i.e. I = 15-(0.7*Vout)mA
Output Rating - Sourcing: 2.5mA (i.e. minimum of 4kΩ)

What are the codes for 4 channel, 10A, CBus relays?

L5504RVF - DIN rail mounted 4 channel 10A relay with power supply
L5504RVFP - DIN rail mounted 4 channel 10A relay without CBus power supply

What is the current rating per channel for an L5504D2UP

The current rating per channel is 2.5A

What is the code for a CBus 4 channel relay without power supply

 Part code L5504RVFP

Does the L5504RVF have it's own power supply?

Yes it has a 200mA power supply..
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=L5504RVF
User-added image
 

What is part no for power supply to suit L5504D2UP

Part no 5500PS
for  more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=5500PS

User-added image

How many CT's can I have per unit for the CBUS current Measurement units (5504CMU & 5100CT80)

4. However Multiple Current Measurements units (CMU's) can be added to the C-BUS network.

How often is the information recorded in the C-Bus Current Measurement Units (5504CMU & 5100CT80)

You can review your energy consumption by the hour, day, week or month.  You can also make comparisons with historical data.

What is the warranty period for the C-Bus Current Measurement Units (5504CMU & 5100CT80)

2 years from the date of installations (4 years when installed by an approved installer)

Is part number L5504D2U suitable for dimming LED?

Yes. The L5504D2U is suitable for LED dimming.

Key Features

  • 4 channel Leading Edge/Trailing Edge
  • 12M DIN modules wide
  • 4 channels of 2.5A rating
  • Suitable for low voltage electronic transformers, incandescent lamps and low voltage lamps with iron core transformersl
  • automatic load sensing
  • software selectable network burden and C-Bus system clock
  • inbuilt 200mA C-Bus power supply
  • C-Bus Learn Enabled
  • for use with Leading Edge or Trailing Edge compatible low voltage transformers
  • 215 mm x 85 mm x 65 mm
for more information, please visit:https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5504D2U

 

What is the part number for a Cbus Universal Dimmer ?

The part nos is

L5504D2U  > this has inbuilt power supply
L5504D2UP > this has NO inbuilt power supply

This is the link to the webpage https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5504D2U
https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5504D2UP

User-added image
 

What are the C-BUS Relay part numbers?

You have several options for relays, Catalogue numbers and information below.

L5504RVF, L5504RVFP** - 4 Channel voltage free relay - 10amps per channel
L5508RVF, L5508RVFP** - 8 Channel voltage free relay - 10amps per channel
L5512RVF, L5512RVFP** - 12 Channel voltage free relay - 10amps per channel

L5504RVF20, L5504RVF20P** - 4 Channel voltage free relay - 20amps per channel

L5508RELVP - 8 Channel Extra Low Voltage Relay

5101R - Single and Two Channel 250v AC 10amp relay
5102RVF - Single and Two Channel 250v AC 10amp Voltage Free Relay

** Any part number that has a 'P' after the part number for Din Rail mount units does NOT include a C-Bus 200ma Power Supply.

What is the replacement for 5101R,1 Channel C-Bus Relay 250V AC 10A inductive load?

Unfortunately we do not have a direct replacement for 5101R. L5504RVFP would be an alternate.
 

Key Features

  • 220 - 240 V AC supply voltage
  • 47 - 53 Hz and 57 - 63 Hz supply frequency
  • Single phase
  • Voltage free, magnetically latched contact type
  • Greater than 60,000 switching operations
  • Compatible with resistive, inductive, incandescent and fluorescent loads up to 10 A
  • 2 x 1.5 mm² or 1 x 2.5 mm² terminals
  • 0˚C - 45˚C operating temperature
  • 10 - 95% RH, humidity range
  • 8 DIN modules
  • DIN mounted
  • 2 x RJ45 sockets connection

For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5504RVFP

What to do when C-Bus dimmer channel will not turn off ?

First of all check that the programming is correct.
If using LED lights, the LED may stay on when the channel is off, this is due to the leakage current being enough to power the LED, use of a 31LCDA may resolve this issue.
If using Halogen and  the channel will not turn off, there may be damage to the electronics on this channel - Electricians only to perform this check, disconnect the Active's , Neutral and Earth from the unit, remove the cable for the load on that channel then with a multimeter check between the Neutral and that suspect channel output, if you see a low resistance the Triac has shorted.
Advise not to use this channel and label as faulty, other channels on this dimmer should still be ok to use as per normal, alternatively you could return this unit for a quote on repair, note a repair may not be possible.

What are the C-Bus Channel Limitation for Current Measurement Unit?

There will be limitations on how many CMU channels that can be utilized, depending on the device being used. This is due to memory limitations of those devices, as to how much historical data can be retained.

Below is a list of the maximum CMU Channels that can be used. Each CMU has 4X Channels per unit.
Each CT Coil has a selection range of either 0-40 and 0-80 AMP Range - This is software selectable.
 
Description CMU Channels
Schedule + 28
Homegate 20
CTC Colour 20
PAC 4
Wiser   4
B&W/Spectrum 4

5504CMU Current Measurement Unit,
Some key features are:
  • Measures and reports over C-Bus a circuit’s instantaneous electrical power consumption
  • Current monitoring is performed via a split core CT (current transformer)
  • 4 channel unit (measure up to 4 electrical circuits per unit)
  • Display energy use on C-Bus 6.4 inch colour touch screen, Schedule Plus, HomeGate Software and Wiser Home Control
  • Raise C-Bus alerts and warning messages based on predefined thresholds
  • Control electrical devices based on predefined thresholds (load shed)
  • Can provide confirmation that electrical devices are operating as expected
  • DIN rail mounted, 4M wide