Max 4 Neutral Active Meter Links, 18 Hole, Neutral Link

Max 4 Neutral Active Meter Links, 18 Hole, Neutral Link

Max 4 Neutral Active Meter Links, 18 Hole, Neutral Link

Item Number: L18

Retail
$192.50
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Range of product

Blue Point

Product or component type

neutral link

Physical

[In] rated current

100 A

[Ue] rated operational voltage

500 V

Connector type

screw terminals

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Others

Cable cross section

16-16 mm²

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

142 g

Package 1 Height

36 mm

Package 1 width

56 mm

Package 1 Length

84 mm
Show all specifications

Frequently Asked Questions

hide show

What is part number for lockable door kit to suit L18S?

The part number for lockable door kit to suit L18S is MGL18DL.

What is the width and height of the PDL 675HRCD

145 x 118

Is there delay that can be added to the start signal for ATV61/71 drives?

Issue:
Is delayed Start available on the Altivar 61 or Altivar 71 VFDs?

Product Line:
Altivar 71, ATV71

Environment:
All

Cause:
NA

Resolution:
Yes, but with a limited time adjustment.
L1-  [LI1 CONFIGURATION]
L1d  [LI1 On Delay]
 0 to 200 ms
Factory Setting  0


This parameter is used to take account of the change of the logic input to state 1 with a delay that can be
adjusted between 0 and 200 milliseconds, in order to filter out possible interference. The change to state 0
is taken into account without delay.

What distribution board is required for the CH25843 chassis?

For the customized distribution board for 72 pole (18 mm) and 12 pole (27 mm) chassis, you need to submit request for a quote to "au.estimating@schneider-electric.com". Our Standard distribution board only goes up to 60 pole (18 mm) and 12 pole (27 mm).

Are tyre inflators still available?

No. Unfortunately,they are no longer available.

Alternatively, contact Airtec Corporation Pty Ltd

PH 1800 818 884

Is there a neutral bar which has 14 to 16 holes?

Yes we have a Neutral bar with both 14 and 16 holes. The part number for a 14 hole neutral bar is L14 and The part number for a 16 hole neutral bar is L16.

Some of the key features for the L14 are :
  • Two screw In 8 Tunnel and One Screw In 6 Tunnel
  • 2 tunnel, 6.3 mm Diameter accommodate 1 x 16 sq mm cable
  • 6 Tunnel, 5.5 mm Diameter accommodate 1 x 16 sq mm cable
  • 6 Tunnel, 4.5 mm Diameter accommodate 1 x 16 sq mm cable
  • Dimensions: 86 x 57 x 40 mm
  • 100A Rated


Some of the key features for the L16 are:
  • Two screw in 6 tunnels and one screw in 10 tunnel
  • 2 tunnels, 6.3 mm Diameter accommodate 1 x 16 sq mm cable
  • 4 Tunnels, 5.5 mm Diameter accommodate 1 x 16 sq mm cable
  • 10 Tunnels, 4.5 mm Diameter accommodate 1 x 10 sq mm cable
  • Dimensions: 86 x 57 x 40 mm
  • 100A rated


For further information please visit https://www.clipsal.com/Trade/search-results?q=Neutral%20Link

 

What is the replacement for XS1N18PA340D Proximity?

The replacement for XS1N18PA340D Proximity is XS518B1PAM12
XS518B1PAM12 inductive sensor XS5 M18 - L50mm - brass - Sn 5mm - 12..24VDC - M12 connector

 

What is the replacement for XS1N12PA349 PROX?

The replacement for is a  XS612B1PAL2
User-added image
XS618B1PAL2 
inductive sensor XS6 M18 - L62mm - brass - Sn8mm - 12..48VDC - cable 2m

For more information see: https://www.tesensors.com/au/en/product/inductive-capacitive/xs-xt-ref/?cat_id=BU_AUT_515_L3&conf=sensors&el_typ=product&prd_id=XS618B1PAL2&scp_id=Z000

What is the dimensions for the PDL range of cover plates

The single cover plate is 118 x 74mm
The double cover which covers two subplates plates is 118mm x 145mm

What is the wire size and torque specs for C60 Multi 9 circuit breakers with lugs?

Issue:
Wire size for Multi 9

Product Line:
Circuit breakers

Environment:
Multi 9 MCB

Cause:
Torque and wire size is marked on the breaker, but users often want this information before they receive the product.

Resolution:
Wire size and torque are as noted below.  Always confirm with markings on the circuit breaker. Only one wire can be installed per terminal. There are no replacement lug kits available for the Multi 9 breakers. The wire strip length is 14 mm.

UL 1077 Supplementary Protectors
0.5 to 25 A: #18 to #4 AWG (1 to 25 mm2) cables; torque 22 lb-in (2.49 N•m)
30 to 63 A: #18 to #2 AWG (1 to 35 mm2) cables; torque 31 lb-in (3.50 N•m)

UL 489 240 Vac
0.5–25 A: #14 to #4 AWG (2–25 mm2) cables; torque to 22 lb-in. (2.48 N•m)
30–35 A: #14 to #2 AWG (1–35 mm2) cables; torque to 31 lb-in. (3.52 N•m)

UL 489 Listed 480 Vac
All amperages: #18 to #16 AWG (1–1.5 mm2), Cu only stranded wire; torque to 7 lb-in (0.68 N•m); #14 to #10 AWG (2–5 mm2), Cu only solid or stranded wire; torque to 14 lb-in (1.6 N•m)

IEC Rated C60 C60N/H/L Except C60L-MA
0.5–25 A: #18 to #4 AWG (1–25 mm2) Cu only cables; torque to 22 lb-in (2.5 N•m)
30–63 A: #18 to #2 AWG (1–35 mm2) Cu only cables; torque to 31 lb-in (3.5 N•m)

What is the connector to fit the XUM2AKCNM8T proximity switch

The connector is an M8 4 pin female connector
XZCPV0941L2 for a straight connector with PVC cable
XZCPV1041L2 for an angled connector with PVC cable
XZCP0941L2 for a straight connector with PUR cable for severe environments
XZCPA0941L2 for a straight connector for food & beverage applications
(change L2 to L5 or L10 for 5 or 10m cables)
See attached data sheet

Can my project name be letters instead of numbers?

You can use any combination of letters and numbers as long as the full order reference does not exceed *18 digits.
Show More