90X90 ADAPTOR PLATE V3/V4

90X90 Adaptor Plate V3/V4

Catalogue Number: KZ106
90X90 ADAPTOR PLATE V3/V4
Retail
$121.06
RRP (Inc. GST)

Specifications

hide show
Range of product
VARIO
Accessory / separate part designation
adaptor plate
Accessory / separate part type
plate
Accessory / separate part category
adaptation accessories
Product compatibility
  • V3
  • V4
    • Accessory / separate part destination
      switch disconnector with front plate 90 x 90 mm
      Quantity per set
      set of 5
      Net weight
      0.075 kg
      Package 1 Weight
      0.059 kg
      Package 1 Height
      0.5 dm
      Package 1 width
      1.05 dm
      Package 1 Length
      1 dm
      Sustainable offer status
      Green Premium product
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Compliant
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      X
      Environmental Disclosure
      ENVPEP110227EN
      WEEE
      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
      California proposition 65
      WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
      Warranty
      18 months

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Product Environmental

      Frequently Asked Questions

      hide show

      I am getting EB106 on a LXM32A drive

      Issue:
      Getting EB106 on a LXM32A drive and I cannot find it in the catalogue

      Product Line:
      Lexium 32

      Resolution:
      EB106 error means I/O data mapping error.
      This error only occurs if the drive is controlled via CANmotion and the mapping is incorrect.
      It means the needed mapped objects like 60FF (Target Velocity), 6071 (Target torque), 607A (Target Position)... are not mapped or are double mapped.

      What is the part code for a Escutcheon plate for a 31106 - INS250 load break switch

      Use a 31079 escutcheon plate

      What is the NZ Equivalent for a 43850 IN250

       The part code is 31106 which is an INS250

      Does the 31106 come with a handle?

       It comes complete with a direct handle. Extended rotary handles are available as an extra.

      How can a BCM module be programmed for 2w modbus on a 4w communication system?

      Issue:
      Applying BCM programmed for 2 wire modbus to a 4 wire modbus system

      Product Line:
      Powerpact and Masterpact breakers with modbus communications

      Environment:
      Applies to trip units with BCM

      Resolution:
      1. With a newer Micrologic P or H trip unit you may re-program the BCM module to 4w.  This requires firmware version 2010AK or newer.
      2. If the trip unit does not have this option or if it is an A trip unit, you may use a 2w to 4w converter, CNV-100.  See the Attached Instruction Bulletin for more details.
      3. Schneider sales offices can also order a BCM programmed for 4w modbus.  Order the module number, 33106 in Q2C with a note that you want it programmed for "4w Modbus."  
        BCM 33106 profile is available only on Q2C Tool. Regional Field Offices to support order submission for customers who are unable to access Q2C.

      Will a short-depth Smart-UPS fit into the NetShelter WX AR106 or AR109 wall box?

      Issue:
      Need to check mounting depth of the UPS, and available space between the front mounting rails and rear of the wall box. 

      Product Line:
      NetShelter WX

      Environment:
      All versions and serial ranges.

      Cause:
      The new Short Depth UPS may fit into a small wall box. 

      Resolution:

      The new Short Depth Smart-UPS will not fit into AR106 or AR109 because there is not enough room to connect power cords into the UPS. 
      The AR106 and AR109 have about 13" of available mounting depth, as measured from the front mounting rails to the rear of the cabinet. 
      A UPS would need to have a mounting depth of 11.25" or less to allow room power cords to plug in. 

      You can also find compatibility to all NetShelter cabinets and APC products by Googling "netshelter accessory compatibility chart" and pulling up FAQ 158651: https://www.apc.com/us/en/faqs/FA158651/ 

      What is the part number for the Auxiliary to suit the INS Load break swiich, 31106?

      The part number for the Auxiliary to suit the INS Load break swiich, 31106 is part number 29450.
      See data sheet for more information:
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=29450
      User-added image

      What is the part number for an INS250 isolator and rotary handle?

      the part number for an INS250 isolator and rotary handle is - 31106 & LV431050

      For further information , visit links below:-
      https://www.schneider-electric.com.au/en/search/LV431050
      https://www.schneider-electric.com.au/en/search/31106
      User-added image
      User-added image
       

      What is the static load capacity of a NetShelter WX wall mount cabinet?

      Issue:
      I customer is asking for static load capacity of a NetShelter WX cabinet. It's not noted in the Specification tab on the APC website. 

      Product Line:
      NetShelter WX

      Environment:
      All versions and serial ranges.

      Cause:
       A customer needs to make sure they don;t exceed the load rating, or that it meets their needs. 

      Resolution:

      All of the NetShelter WX cabinets have a static load rating of 200 lbs. 
       

      What are the sizes of the conduit openings on the 9001KY enclosures?

      Issue:
      9001KY Enclosure conduit size 

      Product Line: 
      9001 KY and SKY Control stations

      Environment:
      n/a

      Resolution:
      9001KY1 thru 9001KY6 is 3/4 inch.
      9001KY9 is 1 inch.
      9001KY12 is 1 1/4 inch.
      9001KY16 is 1 1/2 inch.

      How do I resolve the build message "C0106: Out of global data memory" in SoMachine Logic Builder?

      Issue
      When attempting to Download or Code Generate my PLC Application in SoMachine Logic Builder,  the build message "C0106: Out of global data memory" appears in the Messages zone.

      Product Line
      SoMachine v3.0, SoMachine v3.1, SoMachine v4.1, SoMachine v4.2, SoMachine v4.3
      M238, M241, M251, M258, LMC058, XBTGC, HMISCU, XBTGT w/ Control, XBTGK w/ Control

      Environment
      SoMachine Logic Builder, Windows 7, Windows 10

      Cause
      The build message "C0106: Out of global data memory" is caused by the application having more variables used in the Persistent Retain memory than there is physical memory on the PLC.

      Resolution
      Reduce the number of variables declared in the PersistentVars Application object or declared as "VAR_GLOBAL PERSISTENT RETAIN" in the Global Variable List (GVL) node.
      Do this incrementally and go to the Build menu and perform the following actions in sequence:
      1. Clean
      2. Build
      3. Generate Code
       
      After each Generate Code, check the Message list to see if the C0106 message has disappeared.

      If so, one can see the used memory in the message list in the form of "Memory area 5 contains Persistent Data:…"
      For example in Screenshot 2 below, 2044bytes is the maximum for the HMISCU PLC - of which 46% is used.
       
      Tip: Watch for ARRAYs, DUT (structures) and combinations of the two (ARRAYs of DUTs), which can increase the defined memory usage multiplicatively.
       
      To see how many bytes the PLC has allocated to the Persistent Retain Variables area, go to the SoMachine Online Help [PLC type section] -> Programming Guide -> Memory Mapping section
       

      What is the breakdown of components for 9001KYK117?

      Issue:
      Breakdown of components for 9001KYK117  

      Product Line:
      Harmony Push Buttons

      Environment:
      Harmony Control Stations

      Cause:
      Product Features

      Resolution:
      9001KYK117 components are:
      1-9001KY1S1 (red enclosure)
      1-9001K15 (break glass operator)
      1-9001KA1 (1 open and 1 closed contact)
      1-9001KN799RP (legend plate)

      Replacement glass discs are 9001K57 (package of five)