Quantcast

Sup for 90X90 Without Lab

Sup for 90X90 Without Lab

Sup for 90X90 Without Lab

Item Number: KZ101

Retail
$21.74
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Sustainable offer status

Green Premium product

Warranty

18 months

Range of product

VARIO

Physical

California proposition 65

WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

Environmental Disclosure

ENVPEP110227EN

Mercury free

Yes

REACh free of SVHC

Yes

REACh Regulation

Free of Substances of Very High Concern above the threshold

China RoHS Regulation

X

EU RoHS Directive

Compliant

RoHS exemption information

Yes

Toxic heavy metal free

Yes

Quantity per set

set of 5

Net weight

0.07 kg

Others

Unit Type of Package 1

PCE

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Number of Units in Package 1

1

Package 1 Height

13.5 cm

Package 1 Length

9 cm

Package 1 Weight

14 g

Package 1 width

1.5 cm

Accessory / separate part designation

legend holder without legend plate

Accessory / separate part type

legend holder

Accessory / separate part category

marking accessories

Accessory / separate part destination

front plate 90 x 90 mm
Show all specifications

Frequently Asked Questions

hide show

What is the difference between a 9001KYSS2 and a 9001KYSS200?

Issue:
What is the difference between a 9001KYSS2 and a 9001KYSS200?

Product Line:
Control Stations

Environment:
All products

Cause:
Product Features

Resolution:
The 9001 KYSS2 is a 2 hole stainless steel control station enclosure. The 9001 KYSS200 indicates a custom assembled pushbutton station built with the KYSS2 enclosure. The 9001KYSS200 requires a key sheet be filled out.


CTA-ID : 13484

What are the sizes of the conduit openings on the 9001KY enclosures?

Issue:
9001KY Enclosure conduit size 

Product Line: 
9001 KY and SKY Control stations

Environment:
n/a

Resolution:
9001KY1 thru 9001KY6 is 3/4 inch.
9001KY9 is 1 inch.
9001KY12 is 1 1/4 inch.
9001KY16 is 1 1/2 inch.

What is the breakdown of components for 9001KYK117?

Issue:
Breakdown of components for 9001KYK117  

Product Line:
Harmony Push Buttons

Environment:
Harmony Control Stations

Cause:
Product Features

Resolution:
9001KYK117 components are:
1-9001KY1S1 (red enclosure)
1-9001K15 (break glass operator)
1-9001KA1 (1 open and 1 closed contact)
1-9001KN799RP (legend plate)

Replacement glass discs are 9001K57 (package of five)

Where is the ATV61HD45N4 EMC filter connection located?

Issue:
ATV61HD45N4 EMC filter connection location.

Product Line:
ATV61, ATV71

Environment:
All

Cause:
Need to disconnect EMC filter

Resolution:
The EMC filter is located on SW101 of the Filter Board. Have to look inside the drive at bottom left.

How to calculate MOD1K in Modbus Device Importer

Issue
User is looking to create a driver for 3rd party device that uses MOD 1K to store accumulated information
Example
Register 40100 Wh
Register 40101 kWh
Register 40102 MWh

Product
Power Monitoring Expert 7.2.x, 8.x, 9.0
StruxureWare Power Monitoring 7.0.x

Environment
Modbus Device Importer (MDI)

Cause
MDI does not natively support register type MOD 1K, MOD 10K is a supported register type

Resolution
*Warning: Take backups of any files prior to modifying them. Ensure the backups are in a location that will not be overwritten (i.e. the Desktop).*
Note that registers defined as offset will be updated with the slow speed update rate.

Solution includes a combination of scaling, multiplier and offset registers.

1) Create a new register linked to the lowest register, set the scaling to 1000 and multiplier to -1
- Recommend naming this register other than the desired final register name eg kWh Del 10E-3

2) Create a second register. Set the scaling to 1000, and multiplier to -1. Add an offset register created in step 1.
- Recommend naming this register other than the desired final register name- recommend  eg. kWh Del 10E0

3) Create a third register. Set the offset register to the register created in step 2. Add a multiplier to give the correct desired units.
- Name this register the desired measurement name. eg kWh del.

This process can be repeated for more than 3 registers 

How to monitor the SCADAPack x70 time using Modbus.

  • Under the Configuration -SPx70 Controller in RemoteConnect select the object tab.
  • To add the Hour, Minutes and Seconds in the RemoteConnect Object.
  • In Object  Configuration, click add object and enter the following information below when monitoring the HOUR.
  • Assigning modbus register for the HOUR by selecting the modbus tab.
  • click add object and enter the following information below when monitoring the MINUTE.
  • Assigning modbus register for MINUTE by selecting the modbus tab.
  • click add object and enter the following information below when monitoring the SECOND.
  • Assigning modbus register for SECOND by selecting the modbus tab.
  • Hit Apply button then Write the program into the SCADAPackx70 to make changes.
  • Monitor the modbus registers assigned. In this example monitor register 40100 for HOUR, 40101 for MINUTE and 40102 for SECOND.


 
Show More