Quantcast

Canalis KDP, Distribution flexible length - 20 A - 24 m - 3 m between tap-offs

Canalis KDP, Distribution flexible length - 20 A - 24 m - 3 m between tap-offs

Canalis KDP, Distribution flexible length - 20 A - 24 m - 3 m between tap-offs

Item Number: KDP20ED424300

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

Canalis

Range of product

Canalis

Product or component type

busbar trunking

Product compatibility

KDP

Device application

  • lighting
  • power socket distribution

Warranty

18 months

Physical

[Ue] rated operational voltage

230...400 V

[Ie] rated operational current

20 A at 35 °C

Type of packing

spool

Standards

  • EN/IEC 60439-2
  • EN/IEC 61439-6

Length

23 m

Net weight

7.68 kg

IP degree of protection

IP55 conforming to IEC 60529

IK degree of protection

IK07 conforming to IEC 62262

Ambient air temperature for operation

  • 35...40 °C (93 % of In)
  • 40...45 °C (85 % of In)
  • 45...50 °C (76 % of In)
  • 50...55 °C (66 % of In)
  • 0...35 °C (100 % of In)

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Environmental Disclosure

ENVPEP061103EN

Others

Device short name

KDP

Busbar description

flexible bar

[Uimp] rated impulse withstand voltage

4 kV

[Ui] rated insulation voltage

690 V

[Icw] rated short-time withstand current

0.34 kA

[Ipk] rated peak withstand current

3.6 kA

Network frequency

50/60 Hz

Maximum radiated magnetic field

2 pT

THDI

  • 0...15 % 20 A
  • 15...33 % 16 A
  • 33...100 % 14 A

Maximum voltage drop

  • <0.72 v="" with="" power="" factor="1" at="" 50="" hz="" with="" 1a="" for="" 100="" m="">
  • <0.65 v="" with="" power="" factor="0.9" at="" 50="" hz="" with="" 1a="" for="" 100="" m="">
  • <0.58 v="" with="" power="" factor="0.8" at="" 50="" hz="" with="" 1a="" for="" 100="" m="">
  • <0.5 v="" with="" power="" factor="0.7" at="" 50="" hz="" with="" 1a="" for="" 100="" m="">

Linear resistance

  • 6.8 mΩ/m R20 20 °C phase conductor
  • 0.85 mΩ/m X0 20 °C symmetrical components method Ph/PE
  • 27.22 mΩ/m Z0 20 °C symmetrical components method Ph/PE
  • 13.61 mΩ/m Rb0 20 °C impedance method Ph/Ph
  • 13.61 mΩ/m Rb0 20 °C impedance method Ph/N
  • 13.61 mΩ/m Rb0 20 °C impedance method Ph/PE
  • 16.6 mΩ/m Rb1 35 °C at Inc with impedance method Ph/Ph
  • 16.6 mΩ/m Rb1 35 °C at Inc with impedance method Ph/N
  • 16.6 mΩ/m Rb1 35 °C at Inc with impedance method Ph/PE
  • 0.04 mΩ/m Xb 35 °C at Inc and 50 Hz with impedance method Ph/Ph
  • 0.04 mΩ/m Xb 35 °C at Inc and 50 Hz with impedance method Ph/N
  • 8.3 mΩ/m R1 35 °C at Inc and 50 Hz phase conductor
  • 0.04 mΩ/m Xb 35 °C at Inc and 50 Hz with impedance method Ph/PE
  • 0.02 mΩ/m X1 35 °C at Inc and 50 Hz phase conductor
  • 8.3 mΩ/m Z1 35 °C at Inc and 50 Hz phase conductor
  • 7.25 mΩ/m 20 °C protective conductor
  • 27.21 mΩ/m R0 20 °C symmetrical components method Ph/N
  • 0.85 mΩ/m X0 20 °C symmetrical components method Ph/N
  • 27.22 mΩ/m Z0 20 °C symmetrical components method Ph/N
  • 27.21 mΩ/m R0 20 °C symmetrical components method Ph/PE

Busbar trunking polarity

L2 + L1 + L3 + N + PE

Tap-off unit interval

3000 mm
Show all specifications