Canalis KBA straight length

Catalogue Number: KBA40ED4203

Discontinued

Canalis Straight Distribution Lengths, 40A, 2M

Canalis KBA straight length
Colour:
Colour: Per UOM Std.
  • 1 PCE
Added to cart
Successfully added, you can view your cart here

Key Features & Specifications

hide show
  • 10 and 16 A rated tap-off units current
  • 690 V rated insulating voltage
  • Number of circuits: 1 circuit (2 or 4 conductors)
  • Modular and upgradeable system
  • Quick and easy assembly
  • Dismantled, re-used and entirely recyclable
  • Flexible: possibility to install a light right where it is needed
  • Halogen free: canalis does not emit any fumes or toxic gases in the event of fire
Range
Canalis
Range of product
Canalis
Product or component type
busbar trunking
Device short name
KBA
Product compatibility
KBA
Device application
  • power socket distribution
  • lighting
    • Maximum radiated magnetic field
      2 pT
      [Ue] rated operational voltage
      230...400 V
      [Uimp] rated impulse withstand voltage
      4 kV
      [Ui] rated insulation voltage
      690 V
      [Ie] rated operational current
      40 A at 35 °C
      Network frequency
      50/60 Hz
      [Icw] rated short-time withstand current
      0.94 kA
      [Ipk] rated peak withstand current
      9.6 kA
      Thermal stress limit
      900 kA².s
      THDI
    • 0-15 % 40 A
    • 15-33 % 32 A
    • 33-100 % 28 A
      • Maximum voltage drop
      • <0.3 V with power factor = 1 at 50 Hz with 1A for 100 m long
      • <0.28 V with power factor = 0.9 at 50 Hz with 1A for 100 m long
      • <0.25 V with power factor = 0.8 at 50 Hz with 1A for 100 m long
      • <0.22 V with power factor = 0.7 at 50 Hz with 1A for 100 m long
        • Linear resistance
        • 0.02 mΩ/m X1 35 °C at Inc and 50 Hz phase conductor
        • 0.9 mΩ/m Xb 35 °C at Inc and 50 Hz with impedance method Ph/Ph
        • 0.9 mΩ/m Xb 35 °C at Inc and 50 Hz with impedance method Ph/N
        • 1.57 mΩ/m protective conductor
        • 0.035 mΩ/m Xb 35 °C at Inc and 50 Hz with impedance method Ph/PE
        • 19.4 mΩ/m R0 20 °C symmetrical components method Ph/N
        • 0.38 mΩ/m X0 20 °C symmetrical components method Ph/N
        • 19.41 mΩ/m Z0 20 °C symmetrical components method Ph/N
        • 7.66 mΩ/m Rb0 20 °C impedance method Ph/PE
        • 6.91 mΩ/m Rb1 35 °C at Inc with impedance method Ph/Ph
        • 6.91 mΩ/m Rb1 35 °C at Inc with impedance method Ph/N
        • 2.83 mΩ/m R20 20 °C phase conductor
        • 8.7 mΩ/m Rb1 35 °C at Inc with impedance method Ph/PE
        • 3.46 mΩ/m R1 35 °C at Inc and 50 Hz phase conductor
        • 3.46 mΩ/m Z1 35 °C at Inc and 50 Hz phase conductor
        • 13.83 mΩ/m R0 20 °C symmetrical components method Ph/PE
        • 0.73 mΩ/m X0 20 °C symmetrical components method Ph/PE
        • 13.85 mΩ/m Z0 20 °C symmetrical components method Ph/PE
        • 5.68 mΩ/m Rb0 20 °C impedance method Ph/Ph
        • 5.68 mΩ/m Rb0 20 °C impedance method Ph/N
          • Mounting mode
            by clips
            Busbar description
            straight length
            Busbar trunking polarity
            3L + N + PE
            Number of tap-off outlets
            3
            Control type
            without
            Standards
          • EN/IEC 61439-6
          • EN/IEC 60439-2
            • Width
              2140 mm
              Depth
              30 mm
              Height
              46 mm
              Length
              2 m
              Net weight
              1.9 kg
              Quantity per set
              set of 6
              IP degree of protection
              IP55 conforming to EN/IEC 60529
              IK degree of protection
              IK06 conforming to EN/IEC 62262
              Ambient air temperature for operation
            • 0-35 °C (100 % of In)
            • 35-40 °C (96 % of In)
            • 40-45 °C (93 % of In)
            • 45-50 °C (89 % of In)
            • 50-55 °C (85 % of In)
              • Sustainable offer status
                Green Premium product
                REACh Regulation
                Free of Substances of Very High Concern above the threshold
                REACh free of SVHC
                Yes
                EU RoHS Directive
                Compliant
                Toxic heavy metal free
                Yes
                Mercury free
                Yes
                RoHS exemption information
                Yes
                China RoHS Regulation
                 Pro-active China RoHS declaration (out of China RoHS legal scope)
                Environmental Disclosure
                ENVPEP061101EN
                Circularity Profile
                N/A
                WEEE
                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                Warranty
                18 months

                Documents & downloads

                hide show
                Filter items
                • All

                • Product Brochures

                • CAD Files and Packs

                • Technical Data Catalogues

                • Technical Leaflet

                • Product Environmental

                • Installation Instruction

                • Certificates (MSDS)

                • Declaration of Conformity