OptiLine 50 Trunking Joint cover piece kit for 120 AND 140 trunking

OptiLine 50 Joint Cover Piece, 140 x 63 mm, PC/ABS

Catalogue Number: INS12406

Discontinued

OptiLine 50 Trunking Joint cover piece kit for 120 AND 140 trunking
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
OptiLine 50
Product or component type
joint cover piece
Quantity per set
1 piece
Colour tint
white (RAL 9010)
Trunking dimension
140 x 63 mm
Trunking material
  • aluminium
  • plastic
    • Material
      PC/ABS
      Length
      90 mm
      Height
      144 mm
      Width
      65 mm
      Ambient air temperature for operation
      -25-60 °C
      IP degree of protection
      IP40
      IK degree of protection
      IK07
      Sustainable offer status
      Green Premium product
      REACh Regulation
      Free of Substances of Very High Concern above the threshold
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      Environmental Disclosure
      ENVPEP090918EN
      Warranty
      18 months

      Frequently Asked Questions

      hide show

      What is the key lock replacement for a INS1250?

      You can replace the key lock with the following models

      33190 (https://www.schneider-electric.com/en/product/33190/ronis-keylock---for-masterpact-nt---off-position---2-same-key---el24135/)
      41950 (https://www.schneider-electric.com/en/product/41950/2-key-lock-%2B-1-flat-key).


       

      What is the part number for an end stop for the Optiline 50 ducting , INS12300?

      The part number for an end stop for the Optiline 50 ducting , INS12300 is - INS12304

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=INS12304
      User-added image

      Can part number INS51245 be installed in concrete?

      No part number INS51245 can not be installed in concrete.

      What is the mech module for the Optiline 50 range?

      The part name for the mech module for the Optiline 50 range is as follows: INS62027 (white) or INS62026 (dark grey)

      What is the part number for a pole , floor to ceiling , single sided , tension mounted , with 4 power outlets and 4 data points?

      The part number for a pole , floor to ceiling , single sided , tension mounted , with 4 power outlets and 4 data points is - INS43406 & INS62024 & INS62027

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=INS43406
      https://www.clipsal.com/Trade/search-results?q=INS62024
      https://www.clipsal.com/Trade/search-results?q=INS62027
      User-added image

      What is the code extended front rotary handle / shaft for an INS250?

      Code = 31050

      When running redundant 140CPS124 00 power supplies, is it possible to replace a failed 140CPS124 00 with the 140CPS124 20?

      No. Each power supply making up the redundant pair has to be of the same type. Mixing power supply models may result in unintended operation.







      R-20818

      What are the terminal spreaders that can be used for the INS320?

      LV432490 - 52.5mm Pitch
      Please follow the link for the data sheet:
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LV432490
       

      Non Zero Voltage Readings on ION6200 or Siemens Access 9200 Meters when nothing is connected to the meter's voltage inputs.

      Goals and Symptoms

      Problem:
      ION6200 or Siemens Access 9200 meters with the P24 low DC voltage power supply option will, in some cases, show readings of 1.5 - to 3.0 volts (Voltage Line to Neutral) for all phases, when nothing is connected to the voltage inputs.

      Confirming the Problem:
      If the ground cable is removed from the power supply module the line to neutral voltage reading returns to the correct reading of 0 Volts. Alternatively if you remove the Earth cable from the voltage input terminals the voltage reading returns to the correct reading of 0 Volts.

      Causes and Fixes

      Solution:
      ION6200 or Siemens Access 9200 meters with P24 low DC voltage power supplies will be shipped with ferrites that will cover and attach to the power supply cable. A document containing ferrite installation instructions will be available through the PowerLogic Website (https://www.powerlogic.com or https://www.global.powerlogic.com). All ION6200 or Siemens Access 9200 meters with P24 power supplies shipped after May 14, 2010 will include the ferrite and installation instructions. Those with previously installed ION6200 or Siemens Access 9200 meter types who experience this issue should install a ferrite using the installation instructions on the website. The ferrite information that we are using can be found below:

      Ferrite Information:
      Laird technologies
      Steward
      28A2024-0A2

      Please note:
      As suggested on page 11 of the ION6200 installation guide: Connect the power supply G (ground) terminal to the same point as the meter earth ground terminal.

      Attachments

      (Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/5b44489f905f7e23c12577160010bd53/fl_block_5/0.1AD6?OpenElement&FieldElemFormat=gif)
      Date Created: April 28, 2010
      Last Revised: April 30, 2010
      Public
      Original Author: SN
      All content © 1992-2010 Schneider Electric


      Legacy KB System (APS) Data: RESL202151 V1.0, Originally authored by MiNe on 05/01/2010, Last Edited by MiNe on 05/01/2010
      Related ranges: 9200, ION6200