OptiLine 50 PVC Trunking, T-piece (100,120,140 -> 80)

OptiLine 50 T-Piece, 80 x 63 mm, PC/ABS

Catalogue Number: INS12107

Discontinued

OptiLine 50 PVC Trunking, T-piece (100,120,140 -> 80)
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
OptiLine 50
Product or component type
T-piece
Quantity per set
1 piece
Colour tint
white (RAL 9010)
Trunking dimension
80 x 63 mm
Trunking material
  • plastic
  • aluminium
    • CMS inst product add info
      for vertical trunking 80 and horizontal trunking 100, 120, 140
      Material
      PC/ABS
      Length
      101 mm
      Height
      52 mm
      Width
      63 mm
      Ambient air temperature for operation
      -25-60 °C
      IP degree of protection
      IP40
      IK degree of protection
      IK07
      Sustainable offer status
      Green Premium product
      REACh Regulation
      Free of Substances of Very High Concern above the threshold
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      Environmental Disclosure
      ENVPEP090918EN
      Warranty
      18 months

      Frequently Asked Questions

      hide show

      What is the key lock replacement for a INS1250?

      You can replace the key lock with the following models

      33190 (https://www.schneider-electric.com/en/product/33190/ronis-keylock---for-masterpact-nt---off-position---2-same-key---el24135/)
      41950 (https://www.schneider-electric.com/en/product/41950/2-key-lock-%2B-1-flat-key).


       

      What is the part number for an end stop for the Optiline 50 ducting , INS12300?

      The part number for an end stop for the Optiline 50 ducting , INS12300 is - INS12304

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=INS12304
      User-added image

      What is the part number for the T-Piece for the Actassi trunking?

      T-Piece - ISM11107

      What is the mech module for the Optiline 50 range?

      The part name for the mech module for the Optiline 50 range is as follows: INS62027 (white) or INS62026 (dark grey)

      Why can't I read negative values on my Twido TWDALM3LT analog module with a thermocouple?

      The Twido Analog card TWDALM3LT do not read negative values, this is a hardware limitation. The only way around this would be to use an RTD.

      What is the code extended front rotary handle / shaft for an INS250?

      Code = 31050

      What are the terminal spreaders that can be used for the INS320?

      LV432490 - 52.5mm Pitch
      Please follow the link for the data sheet:
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LV432490
       

      System Manager Software (SMS) v 3.3.x.x or v 4.xx on Windows XP Professional 64-bit, Windows Server 2003 64-bit, or Windows 2008 Operating Systems?


      SMS is not supported on a 64 bit OS.

      • SMS version 3.3.x.x may install, but is not supported.
      • System Manager Software (SMS) version 4.x will not install on a Windows 64-bit Operating System (OS).

      SMS, however, can be run within a virtual machine with a supported OS where that virtual machine is hosted by a 64 bit OS.

      Support is provided for the SMS install only. Licensing to support the VM will be the responsibility of the user. The creation and deployment of the VM and the VM environment are also the responsibility of the user.


      Keywords:
      64 bit

      Legacy KB System (APS) Data: RESL191112 V2.0, Originally authored by PhHa on 02/16/2008, Last Edited by PhHa on 11/09/2009
      Related ranges: System Manager 4.3, System Manager 4.2, System Manager 3.3, System Manager 4.0

      How the mechanical interlocking can be done between Masterpact M and Masterpact NW ACB’s by using two interlocks and one key.

      To interlock the two Air Circuit Breakers (ACBs) with the same key, you need to order the Ronis keylock reference 48550 or Profalux keylock 48546.

      For the Masterpact M, if there is already a keylock installed previously then you need to remove the old keylock from the adaptation kit and you should replace it with the new keylock.

      For Masterpact NW you need to order the adaptation kit reference 48541.

      Note:  

      1. The adaptation Kit 48541 comes without any keylocks, and you will have to order the keylocks as per the above reference provided.