Quantcast

Gv2 GV3 Undervolt Trip 115V Rhs Mt

Gv2 GV3 Undervolt Trip 115V Rhs Mt

Gv2 GV3 Undervolt Trip 115V Rhs Mt

Item Number: GVAX115

Retail
$369.06
RRP (Inc. GST)

Product Dimensions

Width icon

Width18 mm

Height icon

Height89 mm

Depth icon

Depth66 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys GV2

Range

TeSys

Product or component type

safety undervoltage trip

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Range compatibility

GV2ME

Connections - terminals

  • screw clamp terminals 1 cable(s) 1-2.5 mm²solid
  • screw clamp terminals 2 cable(s) 1-2.5 mm²solid
  • screw clamp terminals 1 cable(s) 0.75-2.5 mm²flexible without cable end
  • screw clamp terminals 2 cable(s) 0.75-2.5 mm²flexible without cable end
  • screw clamp terminals 1 cable(s) 0.75-1.5 mm²flexible with cable end
  • screw clamp terminals 2 cable(s) 0.75-1.5 mm²flexible with cable end
    • Mechanical durability

      30000 cycles

      Quantity per set

      set of 10

      Height

      89 mm

      Width

      18 mm

      Depth

      66 mm

      Net weight

      0.105 kg

      REACh Regulation

      Free of Substances of Very High Concern above the threshold

      REACh free of SVHC

      Yes

      EU RoHS Directive

      Compliant

      Toxic heavy metal free

      Yes

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

      X

      Environmental Disclosure

      ENVPEP111252EN

      California proposition 65

      WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

      Others

      Device short name

      GVAX

      [Uc] control circuit voltage

      110...115 V AC 50 Hz

      Control circuit voltage limits

      0.85...1.1 Un

      [Ui] rated insulation voltage

    • 690 V AC conforming to IEC 60947-1
    • 600 V AC conforming to UL 60947-4-1
    • 600 V AC conforming to CSA C22.2 No 60947-4-1
      • Threshold tripping voltage

        0.7...0.35 Un

        Inrush power in VA

        12-12 VA AC

        Inrush power in W

        8 W

        Hold-in power consumption in VA

        3.5-3.5 VA AC

        Hold-in power consumption in W

        1.1-1.1 W

        Operating time

        10...15 ms conforming to IEC 60947-1

        On-load factor

        100 %

        Tightening torque

        < 1.4 N.m on screw clamp terminals

        Compatibility code

        GVAX

        Package 1 Weight

        0.129 kg

        Package 1 Height

        0.83 dm

        Package 1 width

        0.36 dm

        Package 1 Length

        0.91 dm

        WEEE

        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
        Show all specifications

        Documents & downloads

        hide show
        Filter items
        • All

        • CAD Files and Packs

        • Product Brochures

        • Technical Data Catalogues

        • Product Environmental

        • Installation Instruction

        • eTechPub

        Frequently Asked Questions

        hide show

        How many of GVAN11 side Auxiliary can be put on GV3 circuit breakers?

        Maximum of 2 sides mounted Auxiliary can be used with GV3 circuit breaker.
         

        Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

        Issue:
        Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
         
        Product Line:

        Tesys GV Manual Starter and Protectors

        Environment:
        TeSys GV, GVA, GV2, GV3P

        Resolution:
        These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.