Safety undervoltage trip TeSys GVAX for TeSys GV2ME, 110VAC to 440VAC, with screw clamp connection

Gv2 GV3 Undervolt Trip 115V Rhs Mt

Catalogue Number: GVAX115
Safety undervoltage trip TeSys GVAX for TeSys GV2ME, 110VAC to 440VAC, with screw clamp connection
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
TeSys GV2
Range
TeSys
Device short name
GVAX
Product or component type
safety undervoltage trip
Product compatibility
GV2ME
[Uc] control circuit voltage
110...115 V AC 50 Hz
Control circuit voltage limits
0.85...1.1 Un
[Ui] rated insulation voltage
  • 600 V AC conforming to UL 508
  • 690 V AC conforming to IEC 60947-1
  • 600 V AC conforming to CSA C22.2 No 14
    • Threshold tripping voltage
      0.7...0.35 Un
      Inrush power in VA
      12-12 VA AC
      Inrush power in W
      8 W DC
      Hold-in power consumption in VA
      3.5-3.5 VA AC
      Hold-in power consumption in W
      1.1-1.1 W for DC network
      Operating time
      10...15 ms conforming to IEC 60947-1
      On-load factor
      100 %
      Connections - terminals
    • screw clamp terminals 1 cable(s) 0.75-2.5 mm²flexible without cable end
    • screw clamp terminals 1 cable(s) 1-2.5 mm²solid
    • screw clamp terminals 2 cable(s) 0.75-2.5 mm²flexible without cable end
    • screw clamp terminals 2 cable(s) 1-2.5 mm²solid
    • screw clamp terminals 1 cable(s) 0.75-1.5 mm²flexible with cable end
    • screw clamp terminals 2 cable(s) 0.75-1.5 mm²flexible with cable end
      • Tightening torque
        < 1.4 N.m on screw clamp terminals
        Mechanical durability
      • 10000 cycles with GV3P and GV3L
      • 30000 cycles with GV2ME and GV2P
        • Quantity per set
          set of 10
          Net weight
          0.105 kg
          Compatibility code
          GVAX
          Sustainable offer status
          Green Premium product
          REACh Regulation
          Free of Substances of Very High Concern above the threshold
          REACh free of SVHC
          Yes
          EU RoHS Directive
          Compliant
          Toxic heavy metal free
          Yes
          Mercury free
          Yes
          RoHS exemption information
          Yes
          China RoHS Regulation
          X
          Environmental Disclosure
          ENVPEP111252EN
          WEEE
          The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
          Warranty
          18 months

          Documents & downloads

          hide show
          Filter items
          • All

          • CAD Files and Packs

          • Product Brochures

          • Technical Data Catalogues

          • Product Environmental

          • Installation Instruction

          • eTechPub

          Frequently Asked Questions

          hide show

          Does the GVAE11 auxilliary contact block fit the GV2ME?

          The GVAE11 auxilliary contact block fits in the top of the GV2ME and GV2P/L

          How many of GVAN11 side Auxiliary can be put on GV3 circuit breakers?

          Maximum of 2 sides mounted Auxiliary can be used with GV3 circuit breaker.
           

          What is the part name for the side mount auxiliary contacts 1 N/C , 1N/O for GV3P40?

          The part name for the side mount auxiliary contacts is - GVAN11.

          Will GVAN11 give fault indication?

          No, the GVAN11 will only give status of "off" or "on" of the Breaker, but no indication of "fault".

          The GVAD1010 and GVAD0110 will give fault indication and status of "off" or "on" of the breaker.

          The GVAM11 will give short circuit contact signaling .

          For further information please visit https://www.schneider-electric.com.au.

          What is the part number to get 2 extra N/C auxillary contacts on to a GV Motor C/B?

          The part numbers to get 2 extra N/C auxillary contacts on to a GV Motor C/B are - GVAE11 & GVAN11
          For further information , visit links below:-
          https://www.schneider-electric.com.au/en/search/GVAE11
          https://www.schneider-electric.com.au/en/search/GVAN11
           

          Can GVAU225 operate on 60 HZ?

          Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

          Issue:
          Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
           
          Product Line:

          Tesys GV Manual Starter and Protectors

          Environment:
          TeSys GV, GVA, GV2, GV3P

          Resolution:
          These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.

          What is the fault aux contact for a GV2 which has a normally open contact

           The part code GVAD1010

          What is the length of the shaft in the GV3APN02 kit?

           The shaft included in the GV3APN02 kit is a GVAPA1. It has a length of 315 mm.
           

          Will the Compact NSX breaker be for sale in the USA or Canada?

          Issue:
          Where can I buy a Compact NSX breaker?

          Product Line:
          Circuit Breakers

          Cause:
          This breaker is popular overseas and there is interest in the US

          Resolution:
          There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

          If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

          For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
          https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page