Gv2 GV3 Undervolt 240V Rhs Mount

Gv2 GV3 Undervolt 240V Rhs Mount

Gv2 GV3 Undervolt 240V Rhs Mount

Item Number: GVAS225

Retail
$229.01
RRP (Inc. GST)

Product Dimensions

Width icon

Width18 mm

Height icon

Height89 mm

Depth icon

Depth66 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

  • TeSys GV2
  • TeSys GV3
    • Range

      TeSys

      Product or component type

      shunt trip release

      Sustainable offer status

      Green Premium product

      Warranty

      18 months

      Physical

      Range compatibility

    • GV2ME
    • GV2LE
    • GV2L
    • GV2P
    • GV3L
    • GV3P
      • Connections - terminals

      • screw clamp terminals 1 cable(s) 1-2.5 mm²solid
      • screw clamp terminals 2 cable(s) 1-2.5 mm²solid
      • screw clamp terminals 1 cable(s) 0.75-2.5 mm²flexible without cable end
      • screw clamp terminals 2 cable(s) 0.75-2.5 mm²flexible without cable end
      • screw clamp terminals 1 cable(s) 0.75-1.5 mm²flexible with cable end
      • screw clamp terminals 2 cable(s) 0.75-1.5 mm²flexible with cable end
        • Mechanical durability

        • 10000 cycles with GV3P and GV3L
        • 30000 cycles with GV2ME and GV2P
          • Quantity per set

            set of 10

            Height

            89 mm

            Width

            18 mm

            Depth

            66 mm

            Net weight

            0.105 kg

            REACh free of SVHC

            Yes

            EU RoHS Directive

            Compliant

            Toxic heavy metal free

            Yes

            Mercury free

            Yes

            RoHS exemption information

            Yes

            China RoHS Regulation

            X

            Environmental Disclosure

            ENVPEP111252EN

            Others

            Device short name

            GVAS

            [Uc] control circuit voltage

            220...240 V AC 50 Hz

            Control circuit voltage limits

            0.7...1.1 Un

            [Ui] rated insulation voltage

          • 690 V AC conforming to IEC 60947-1
          • 600 V AC conforming to UL 60947-4-1
          • 600 V AC conforming to CSA C22.2 No 60947-4-1
            • Threshold tripping voltage

              0.75...0.2 Un

              Inrush power in VA

              14-14 VA AC

              Inrush power in W

              10.5 W

              Hold-in power consumption in VA

              5-5 VA AC

              Hold-in power consumption in W

              1.6-1.6 W

              Operating time

              10...15 ms conforming to IEC 60947-1

              On-load factor

              100 %

              Tightening torque

              < 1.4 N.m on screw clamp terminals

              Compatibility code

              GVAS

              Unit Type of Package 1

              PCE

              Number of Units in Package 1

              1

              Package 1 Weight

              115 g

              Package 1 Height

              3.7 cm

              Package 1 width

              8.3 cm

              Package 1 Length

              9.3 cm

              Unit Type of Package 2

              BAG

              Number of Units in Package 2

              1

              Package 2 Weight

              115 g

              Package 2 Height

              3.5 cm

              Package 2 width

              9 cm

              Package 2 Length

              8.5 cm

              Unit Type of Package 3

              S01

              Number of Units in Package 3

              16

              Package 3 Weight

              2.042 kg

              Package 3 Height

              15 cm

              Package 3 width

              15 cm

              Package 3 Length

              40 cm

              WEEE

              The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
              Show all specifications

              Documents & downloads

              hide show
              Filter items
              • All

              • CAD Files and Packs

              • Product Brochures

              • Technical Data Catalogues

              • Product Environmental

              • Installation Instruction

              • eTechPub

              Frequently Asked Questions

              hide show

              Can GVAU225 operate on 60 HZ?

              Do we offer a cable operated handle mechanism for the GV7 starters?

              Issue:
              They need to mount the GV7 back inside the enclosure and need a handle mechanism with a cable to operate. 

              Product line:
              Tesys GV7 manual motor controller

              Environment:
              all

              Cause:
              n/a

              Resolution:
              The GV7 do not offer a cable operator.  Consider switching to a Powerpact circuit breaker which offers the cable mechanism kits.

              What is the catalog number for an external rotary handle for a GV7 manual starter ?

              Issue:
              GV7 Manual starter handle kit

              Product Line:
              Motor Starters and Protectors

              Environment:
              TeSys™ GV Manual Starters and Protectors

              Resolution:
              Use the GV7AP01 for a black handle with black legend or a GV7AP02 for a red handle with yellow legend.

              What is the part number for the top mount auxiliary for a GV2L22?

              The part number for the Top mount auxiliary for the GV2 range is the GVAE1....
              This can be a N/O or N/C depending on orientation
              https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=gvae1

              User-added image

              What is the IP rating of GVAE20? Would the IP rating of GV2P circuit breaker (IP20) get affected by the addition of Aux contact GVAE20?

              The IP rating of GVAE20 is IP 20.

              The IP rating of GV2* with GVAE20 is then IP20. It would not get affected by the addition of the Auxiliary 

              Will the accessories used for the GV3ME06 through GV3ME63 work with the GV3ME80?

              Product Line:
              GV3 manual motor starters, IEC

              Resolution:
              The standard GV3 accessories will work on this device.

              Are explosion proof enclosures available for GV manual motor starters.

              Issue:
              NEMA 7/9 rated enclosure for GV manual motor starters

              Product Line:
              Tesys GV Motor Starters and Protectors

              Environment:
              TeSys™ GV Manual Starters and Protectors

              Resolution:
              No hazardous duty enclosures are available for the GV product line.
              For explosion proof applications consider the Class 2510 Type M or Type T offering.

              What does Pitch refer to in regards to the GV2G busbar system?

              Issue: 
              Need to know what 45mm, 54mm, and 72mm pitch means

              Product Line:
              GV2 Manual Starters

              Environment:
              n/a

              Resolution:
              The pitch is the spacing between slots.  In order to select the correct pitch, total up the width of the device, plus any side mounted auxiliaries.  Use the total width for selecting the proper pitch. The busbar pitch selection must be the same or greater than the sum of device and auxiliaries.

              Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

              Issue:
              Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
               
              Product Line:

              Tesys GV Manual Starter and Protectors

              Environment:
              TeSys GV, GVA, GV2, GV3P

              Resolution:
              These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.

              Can the GV* starters be used on 50 hertz applications?

              Issue:
              GV* Starter for 50/60hz application

              Product Line:
              Motor Starters and Protectors

              Environment:
              PowerPact™ Manual Starters

              Resolution:
              Yes, these starters are rated for 50/60 hertz.

              This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.