Quantcast

Gv2 GV3 Undervolt Trip 115V Rhs Mt

Gv2 GV3 Undervolt Trip 115V Rhs Mt

Gv2 GV3 Undervolt Trip 115V Rhs Mt

Item Number: GVAS115

Retail
$229.01
RRP (Inc. GST)

Product Dimensions

Width icon

Width18 mm

Height icon

Height89 mm

Depth icon

Depth66 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

  • TeSys GV2
  • TeSys GV3
    • Range

      TeSys

      Product or component type

      shunt trip release

      Sustainable offer status

      Green Premium product

      Warranty

      18 months

      Physical

      Range compatibility

    • GV2ME
    • GV2LE
    • GV2L
    • GV2P
    • GV3L
    • GV3P
      • Connections - terminals

      • screw clamp terminals 1 cable(s) 1-2.5 mm²solid
      • screw clamp terminals 2 cable(s) 1-2.5 mm²solid
      • screw clamp terminals 1 cable(s) 0.75-2.5 mm²flexible without cable end
      • screw clamp terminals 2 cable(s) 0.75-2.5 mm²flexible without cable end
      • screw clamp terminals 1 cable(s) 0.75-1.5 mm²flexible with cable end
      • screw clamp terminals 2 cable(s) 0.75-1.5 mm²flexible with cable end
        • Mechanical durability

        • 10000 cycles with GV3P and GV3L
        • 30000 cycles with GV2ME and GV2P
          • Quantity per set

            set of 10

            Height

            89 mm

            Width

            18 mm

            Depth

            66 mm

            Net weight

            0.105 kg

            REACh free of SVHC

            Yes

            EU RoHS Directive

            Compliant

            Toxic heavy metal free

            Yes

            Mercury free

            Yes

            RoHS exemption information

            Yes

            China RoHS Regulation

            X

            Environmental Disclosure

            ENVPEP111252EN

            Others

            Device short name

            GVAS

            [Uc] control circuit voltage

          • 127 V AC 60 Hz
          • 110...115 V AC 50 Hz
            • Control circuit voltage limits

              0.7...1.1 Un

              [Ui] rated insulation voltage

            • 690 V AC conforming to IEC 60947-1
            • 600 V AC conforming to UL 60947-4-1
            • 600 V AC conforming to CSA C22.2 No 60947-4-1
              • Threshold tripping voltage

                0.75...0.2 Un

                Inrush power in VA

                14-14 VA AC

                Inrush power in W

                10.5 W

                Hold-in power consumption in VA

                5-5 VA AC

                Hold-in power consumption in W

                1.6-1.6 W

                Operating time

                10...15 ms conforming to IEC 60947-1

                On-load factor

                100 %

                Tightening torque

                < 1.4 N.m on screw clamp terminals

                Compatibility code

                GVAS

                Unit Type of Package 1

                PCE

                Number of Units in Package 1

                1

                Package 1 Weight

                116 g

                Package 1 Height

                3.6 cm

                Package 1 width

                8.3 cm

                Package 1 Length

                9.1 cm

                Unit Type of Package 2

                S01

                Number of Units in Package 2

                16

                Package 2 Weight

                2.037 kg

                Package 2 Height

                15 cm

                Package 2 width

                15 cm

                Package 2 Length

                40 cm

                WEEE

                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                Show all specifications

                Documents & downloads

                hide show
                Filter items
                • All

                • CAD Files and Packs

                • Product Brochures

                • Technical Data Catalogues

                • Product Environmental

                • Installation Instruction

                • eTechPub

                Frequently Asked Questions

                hide show

                Does the GVAE11 auxilliary contact block fit the GV2ME?

                The GVAE11 auxilliary contact block fits in the top of the GV2ME and GV2P/L

                How many of GVAN11 side Auxiliary can be put on GV3 circuit breakers?

                Maximum of 2 sides mounted Auxiliary can be used with GV3 circuit breaker.
                 

                What is the part name for the side mount auxiliary contacts 1 N/C , 1N/O for GV3P40?

                The part name for the side mount auxiliary contacts is - GVAN11.

                Will GVAN11 give fault indication?

                No, the GVAN11 will only give status of "off" or "on" of the Breaker, but no indication of "fault".

                The GVAD1010 and GVAD0110 will give fault indication and status of "off" or "on" of the breaker.

                The GVAM11 will give short circuit contact signaling .

                For further information please visit https://www.schneider-electric.com.au.

                What is the part number to get 2 extra N/C auxillary contacts on to a GV Motor C/B?

                The part numbers to get 2 extra N/C auxillary contacts on to a GV Motor C/B are - GVAE11 & GVAN11
                For further information , visit links below:-
                https://www.schneider-electric.com.au/en/search/GVAE11
                https://www.schneider-electric.com.au/en/search/GVAN11
                 

                Can GVAU225 operate on 60 HZ?

                Show More