Shunt trip GVAS for thermal-magnetic motor circuit-breaker GV2 or GV3
Shunt trip GVAS for thermal-magnetic motor circuit-breaker GV2 or GV3
Shunt trip GVAS for thermal-magnetic motor circuit-breaker GV2 or GV3
Shunt trip GVAS for thermal-magnetic motor circuit-breaker GV2 or GV3
Shunt trip GVAS for thermal-magnetic motor circuit-breaker GV2 or GV3
Shunt trip GVAS for thermal-magnetic motor circuit-breaker GV2 or GV3

Gv2 GV3 Undervolt Trip 115V Rhs Mt

Catalogue Number: GVAS115
Shunt trip GVAS for thermal-magnetic motor circuit-breaker GV2 or GV3
Shunt trip GVAS for thermal-magnetic motor circuit-breaker GV2 or GV3
Shunt trip GVAS for thermal-magnetic motor circuit-breaker GV2 or GV3
Shunt trip GVAS for thermal-magnetic motor circuit-breaker GV2 or GV3
Shunt trip GVAS for thermal-magnetic motor circuit-breaker GV2 or GV3
Shunt trip GVAS for thermal-magnetic motor circuit-breaker GV2 or GV3
Retail
$229.01
RRP (Inc. GST)

Specifications

hide show
Range of product
  • TeSys GV2
  • TeSys GV3
    • Range
      TeSys
      Device short name
      GVAS
      Product or component type
      shunt trip release
      Range compatibility
    • GV2ME
    • GV2LE
    • GV2L
    • GV2P
    • GV3L
    • GV3P
      • [Uc] control circuit voltage
      • 127 V AC 60 Hz
      • 110...115 V AC 50 Hz
        • Control circuit voltage limits
          0.7...1.1 Un
          [Ui] rated insulation voltage
        • 690 V AC conforming to IEC 60947-1
        • 600 V AC conforming to UL 60947-4-1
        • 600 V AC conforming to CSA C22.2 No 60947-4-1
          • Threshold tripping voltage
            0.75...0.2 Un
            Inrush power in VA
            14-14 VA AC
            Inrush power in W
            10.5 W
            Hold-in power consumption in VA
            5-5 VA AC
            Hold-in power consumption in W
            1.6-1.6 W
            Operating time
            10...15 ms conforming to IEC 60947-1
            On-load factor
            100 %
            Connections - terminals
          • screw clamp terminals 1 cable(s) 1-2.5 mm²solid
          • screw clamp terminals 2 cable(s) 1-2.5 mm²solid
          • screw clamp terminals 1 cable(s) 0.75-2.5 mm²flexible without cable end
          • screw clamp terminals 2 cable(s) 0.75-2.5 mm²flexible without cable end
          • screw clamp terminals 1 cable(s) 0.75-1.5 mm²flexible with cable end
          • screw clamp terminals 2 cable(s) 0.75-1.5 mm²flexible with cable end
            • Tightening torque
              < 1.4 N.m on screw clamp terminals
              Mechanical durability
            • 10000 cycles with GV3P and GV3L
            • 30000 cycles with GV2ME and GV2P
              • Quantity per set
                set of 10
                Height
                89 mm
                Width
                18 mm
                Depth
                66 mm
                Net weight
                0.105 kg
                Compatibility code
                GVAS
                Unit Type of Package 1
                PCE
                Number of Units in Package 1
                1
                Package 1 Weight
                116 g
                Package 1 Height
                3.6 cm
                Package 1 width
                8.3 cm
                Package 1 Length
                9.1 cm
                Unit Type of Package 2
                S01
                Number of Units in Package 2
                16
                Package 2 Weight
                2.037 kg
                Package 2 Height
                15 cm
                Package 2 width
                15 cm
                Package 2 Length
                40 cm
                Sustainable offer status
                Green Premium product
                REACh free of SVHC
                Yes
                EU RoHS Directive
                Compliant
                Toxic heavy metal free
                Yes
                Mercury free
                Yes
                RoHS exemption information
                Yes
                China RoHS Regulation
                X
                Environmental Disclosure
                ENVPEP111252EN
                WEEE
                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                Warranty
                18 months

                Documents & downloads

                hide show
                Filter items
                • All

                • CAD Files and Packs

                • Product Brochures

                • Technical Data Catalogues

                • Product Environmental

                • Installation Instruction

                • eTechPub

                Frequently Asked Questions

                hide show

                Does the GVAE11 auxilliary contact block fit the GV2ME?

                The GVAE11 auxilliary contact block fits in the top of the GV2ME and GV2P/L

                How many of GVAN11 side Auxiliary can be put on GV3 circuit breakers?

                Maximum of 2 sides mounted Auxiliary can be used with GV3 circuit breaker.
                 

                What is the part name for the side mount auxiliary contacts 1 N/C , 1N/O for GV3P40?

                The part name for the side mount auxiliary contacts is - GVAN11.

                Will GVAN11 give fault indication?

                No, the GVAN11 will only give status of "off" or "on" of the Breaker, but no indication of "fault".

                The GVAD1010 and GVAD0110 will give fault indication and status of "off" or "on" of the breaker.

                The GVAM11 will give short circuit contact signaling .

                For further information please visit https://www.schneider-electric.com.au.

                What is the part number to get 2 extra N/C auxillary contacts on to a GV Motor C/B?

                The part numbers to get 2 extra N/C auxillary contacts on to a GV Motor C/B are - GVAE11 & GVAN11
                For further information , visit links below:-
                https://www.schneider-electric.com.au/en/search/GVAE11
                https://www.schneider-electric.com.au/en/search/GVAN11
                 

                Can GVAU225 operate on 60 HZ?

                Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

                Issue:
                Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
                 
                Product Line:

                Tesys GV Manual Starter and Protectors

                Environment:
                TeSys GV, GVA, GV2, GV3P

                Resolution:
                These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.

                What is the fault aux contact for a GV2 which has a normally open contact

                 The part code GVAD1010

                What is the length of the shaft in the GV3APN02 kit?

                 The shaft included in the GV3APN02 kit is a GVAPA1. It has a length of 315 mm.
                 

                Will the Compact NSX breaker be for sale in the USA or Canada?

                Issue:
                Where can I buy a Compact NSX breaker?

                Product Line:
                Circuit Breakers

                Cause:
                This breaker is popular overseas and there is interest in the US

                Resolution:
                There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

                If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

                For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
                https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page