Item Number: GVAN11

Retail
$89.64
RRP (Inc. GST)

Product Dimensions

Width icon

Width9.3 mm

Height icon

Height89 mm

Depth icon

Depth66 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

  • TeSys GV2
  • TeSys GV3
    • Range

      TeSys

      Product or component type

      auxiliary contact block

      Product compatibility

    • GV2ME
    • GV2RT
    • GV2L
    • GV3P
    • GV3L
    • GV2LE
    • GV2P
      • Sustainable offer status

        Green Premium product

        Warranty

        18 months

        Physical

        [Ue] rated operational voltage

      • 48...690 V AC
      • 24...240 V DC
        • Protection type

        • GB2CB... circuit breaker
        • gG fuse 10 A
          • Mechanical durability

            100000 cycles

            Height

            89 mm

            Width

            9.3 mm

            Depth

            66 mm

            Net weight

            0.05 kg

            Environmental characteristic

            normal environment

            REACh Regulation

            Free of Substances of Very High Concern above the threshold

            REACh free of SVHC

            Yes

            EU RoHS Directive

            Compliant

            Toxic heavy metal free

            Yes

            Mercury free

            Yes

            RoHS exemption information

            Yes

            China RoHS Regulation

            X

            Environmental Disclosure

            ENVPEP111252EN

            California proposition 65

            WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

            Others

            Device short name

            GVAN

            Mounting location

            left side

            Pole contact composition

            1 NO + 1 NC

            [Ui] rated insulation voltage

          • 600 V conforming to UL 508
          • 690 V conforming to IEC 60947-1
          • 600 V conforming to CSA C22.2 No 14
            • [Ith] conventional free air thermal current

              6 A

              Minimum switching current

              5 mA

              Minimum switching voltage

              17 V

              Rated operational power in VA

            • 300 VA at 48-48 V AC-15 - electrical durability: 100000 cycles
            • 414 VA at 690-690 V AC-15 - electrical durability: 100000 cycles
            • 500 VA at 110-127 V AC-15 - electrical durability: 100000 cycles
            • 500 VA at 500-500 V AC-15 - electrical durability: 100000 cycles
            • 650 VA at 440-440 V AC-15 - electrical durability: 100000 cycles
            • 720 VA at 230-240 V AC-15 - electrical durability: 100000 cycles
            • 850 VA at 380-415 V AC-15 - electrical durability: 100000 cycles
              • Rated operational power in W

              • 120 W at 240 V DC-13 - electrical durability: 100000 cycles
              • 140 W at 110 V DC-13 - electrical durability: 100000 cycles
              • 140 W at 24 V DC-13 - electrical durability: 100000 cycles
              • 180 W at 60 V DC-13 - electrical durability: 100000 cycles
              • 240 W at 48 V DC-13 - electrical durability: 100000 cycles
                • Tightening torque

                  1.4 N.m - on screw clamp terminals

                  Compatibility code

                  GVAN

                  Unit Type of Package 1

                  PCE

                  Number of Units in Package 1

                  1

                  Package 1 Weight

                  46 g

                  Package 1 Height

                  1.5 cm

                  Package 1 width

                  7 cm

                  Package 1 Length

                  9 cm

                  Unit Type of Package 2

                  BB1

                  Number of Units in Package 2

                  10

                  Package 2 Weight

                  510 g

                  Package 2 Height

                  9.5 cm

                  Package 2 width

                  10 cm

                  Package 2 Length

                  15.2 cm

                  Unit Type of Package 3

                  S02

                  Number of Units in Package 3

                  60

                  Package 3 Weight

                  3.36 kg

                  Package 3 Height

                  15 cm

                  Package 3 width

                  30 cm

                  Package 3 Length

                  40 cm

                  WEEE

                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                  Show all specifications

                  Documents & downloads

                  hide show
                  Filter items
                  • All

                  • CAD Files and Packs

                  • Product Brochures

                  • Technical Data Catalogues

                  • Product Environmental

                  • Installation Instruction

                  • Technical Drawing

                  • Certificates (MSDS)

                  • eTechPub

                  Frequently Asked Questions

                  hide show

                  Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

                  Issue:
                  Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
                   
                  Product Line:

                  Tesys GV Manual Starter and Protectors

                  Environment:
                  TeSys GV, GVA, GV2, GV3P

                  Resolution:
                  These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.

                  How many of GVAN11 side Auxiliary can be put on GV3 circuit breakers?

                  Maximum of 2 sides mounted Auxiliary can be used with GV3 circuit breaker.
                   

                  What is the wattage on the DL1BA and DL1BL bulbs used in the XVA indicating banks?

                  Issue:
                  What is the power in watts on the DL1BA and DL1BL  bulbs used in the XVA indicating banks?

                  Product Line:
                  Harmony Tower Lights

                  Environment:
                  Harmony XB4/ZB4 Metal Push Buttons

                  Cause:
                  Product Features

                  Resolution:
                  AC or DC
                  2.5W 12V DL1BA012
                  4W 24V DL1BA024
                  6.5W 24V DL1BL024
                  4W 48V DL1BA048
                  7W 110V DL1BA110
                  7W 120V DL1BL120
                  5W 160V DL1BA160
                  6W 260V DL1BA260