Quantcast

Gv2 GV3 Auxiliary Short Cct C/O Lhs

Gv2 GV3 Auxiliary Short Cct C/O Lhs

Gv2 GV3 Auxiliary Short Cct C/O Lhs

Item Number: GVAM11

Retail
$229.01
RRP (Inc. GST)

Product Dimensions

Width icon

Width9.3 mm

Height icon

Height89 mm

Depth icon

Depth66 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Sustainable offer status

Green Premium product

Warranty

18 months

Range of product

  • TeSys GV3
  • TeSys GV2
    • Range

      TeSys

      Product or component type

      auxiliary contact block

      Product compatibility

    • GV2L
    • GV2ME
    • GV2RT
    • GV3L
    • GV2P
    • GV3P
    • GV2LE
      • Physical

        California proposition 65

        WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

        Environmental Disclosure

        ENVPEP111252EN

        Mercury free

        Yes

        REACh free of SVHC

        Yes

        REACh Regulation

        Free of Substances of Very High Concern above the threshold

        China RoHS Regulation

        X

        EU RoHS Directive

        Compliant

        RoHS exemption information

        Yes

        Toxic heavy metal free

        Yes

        Range compatibility

      • GV2 GV2 circuit breaker
      • GV3 GV3P circuit breaker
      • GV3 GV3L circuit breaker
        • Connections - terminals

        • screw clamp terminals 1 cable(s) 1-2.5 mm²solid
        • screw clamp terminals 2 cable(s) 1-2.5 mm²solid
        • screw clamp terminals 1 cable(s) 0.75-2.5 mm²flexible without cable end
        • screw clamp terminals 2 cable(s) 0.75-2.5 mm²flexible without cable end
        • screw clamp terminals 2 cable(s) 0.75-1.5 mm²flexible with cable end
        • screw clamp terminals 1 cable(s) 0.75-1.5 mm²flexible with cable end
          • [Ue] rated operational voltage

          • 24...240 V AC
          • 24...60 V DC
            • Protection type

            • GB2CB... circuit breaker
            • gG fuse 10 A
              • Mechanical durability

                100000 cycles

                Height

                89 mm

                Width

                9.3 mm

                Depth

                66 mm

                Net weight

                0.055 kg

                Environmental characteristic

                normal environment

                Others

                Number of Units in Package 1

                1

                Number of Units in Package 2

                10

                Number of Units in Package 3

                60

                Package 1 Height

                1.5 cm

                Package 1 Length

                7 cm

                Package 1 Weight

                42 g

                Package 1 width

                9 cm

                Package 2 Height

                9.5 cm

                Package 2 Length

                15 cm

                Package 2 Weight

                459 g

                Package 2 width

                10 cm

                Package 3 Height

                15 cm

                Package 3 Length

                40 cm

                Package 3 Weight

                3.22 kg

                Package 3 width

                30 cm

                Unit Type of Package 1

                PCE

                Unit Type of Package 2

                BB1

                Unit Type of Package 3

                S02

                WEEE

                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                Device short name

                GVAM

                Mounting location

                left side

                Auxiliary contacts operation

                short-circuit signal 1 C/O

                Pole contact composition

                1 C/O

                [Ui] rated insulation voltage

              • 690 V conforming to IEC 60947-1
              • 300 V conforming to UL 508
              • 300 V conforming to CSA C22.2 No 14
                • [Ith] conventional free air thermal current

                  2.5 A for fault signalling

                  Minimum switching current

                  5 mA

                  Minimum switching voltage

                  17 V

                  Rated operational power in VA

                • 36 VA at 24-24 V AC-14 - electrical durability: 1000 cycles at 1.5 A
                • 48 VA at 48-48 V AC-14 - electrical durability: 1000 cycles at 1 A
                • 72 VA at 110-127 V AC-14 - electrical durability: 1000 cycles at 0.5 A
                • 72 VA at 230-240 V AC-14 - electrical durability: 1000 cycles at 0.3 A
                  • Rated operational power in W

                  • 120 W at 240 V DC-13 - electrical durability: 100000 cycles
                  • 140 W at 110 V DC-13 - electrical durability: 100000 cycles
                  • 140 W at 24 V DC-13 - electrical durability: 100000 cycles
                  • 180 W at 60 V DC-13 - electrical durability: 100000 cycles
                  • 240 W at 48 V DC-13 - electrical durability: 100000 cycles
                  • 15 W at 48 V DC-13 - electrical durability: 1000 cycles
                  • 24 W at 24 V DC-13 - electrical durability: 1000 cycles
                  • 9 W at 60 V DC-13 - electrical durability: 1000 cycles
                    • Tightening torque

                      1.4 N.m - on screw clamp terminals

                      Compatibility code

                      GVAM
                      Show all specifications

                      Documents & downloads

                      hide show
                      Filter items
                      • All

                      • CAD Files and Packs

                      • Product Brochures

                      • Technical Data Catalogues

                      • Product Environmental

                      • Installation Instruction

                      • Data Bulletin

                      • eTechPub

                      Frequently Asked Questions

                      hide show

                      Can the GV* starters be used on 50 hertz applications?

                      Issue:
                      GV* Starter for 50/60hz application

                      Product Line:
                      Motor Starters and Protectors

                      Environment:
                      PowerPact™ Manual Starters

                      Resolution:
                      Yes, these starters are rated for 50/60 hertz.

                      This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

                      Will the Tesys GV2ME starters install into old style enclosures designed for the GV2M, GV2MC01 and GV2MC02 enclosures?

                      Issue:
                      GV2ME compatibility with old enclosure 

                      Product Line:

                      Motor Starters and Protectors

                      Environment:
                      TeSys™ GV Manual Starters and Protectors
                       
                      Resolution:
                      No, Order new enclosures using the same catalog numbers. The current enclosure has an updated DIN attachement which will accept the Tesys GV2ME starters but will not accept the old GV2M starters.

                      Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

                      Issue:
                      Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
                       
                      Product Line:

                      Tesys GV Manual Starter and Protectors

                      Environment:
                      TeSys GV, GVA, GV2, GV3P

                      Resolution:
                      These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.

                      How many of GVAN11 side Auxiliary can be put on GV3 circuit breakers?

                      Maximum of 2 sides mounted Auxiliary can be used with GV3 circuit breaker.
                       

                      What is the part name for the side mount auxiliary contacts 1 N/C , 1N/O for GV3P40?

                      The part name for the side mount auxiliary contacts is - GVAN11.

                      Is a padlocking device available for the GV2MC** type enclosures?

                      Issue:
                      Padlocking device for GV2MC Enclosures

                      Product Line:
                      TeSys GV2 Manual Starters and Protectors

                      Environment:
                      n/a

                      Resolution:
                      Yes, use the GV2V01. When this is padlocked, the starter is automatically in and will remain in the OFF position.
                      Show More