MASTER YOUR CASTLE with your new build or reno project
Enter competition
Auxiliary contact
MANUAL STARTER AUX CONTACT 575VAC 1AMP I
Instantaneous auxiliary contact block for GV2
Auxiliary contact
MANUAL STARTER AUX CONTACT 575VAC 1AMP I
Instantaneous auxiliary contact block for GV2

GVAE20

Gv2 GV3 Auxiliary N/O N/O Top

Auxiliary contact
MANUAL STARTER AUX CONTACT 575VAC 1AMP I
Instantaneous auxiliary contact block for GV2
Auxiliary contact
MANUAL STARTER AUX CONTACT 575VAC 1AMP I
Instantaneous auxiliary contact block for GV2
Colour:
Colour: Per UOM Std.
  • 1 PCE
Added to cart
Successfully added, you can view your cart here

Key Features & Specifications

hide show
Range of product
  • TeSys GV2
  • TeSys GV3
    • Range
      TeSys
      Device short name
      GVAE
      Product or component type
      auxiliary contact block
      Product compatibility
    • GV2L
    • GV3P
    • GV2ME
    • LS1D32
    • GV3L
    • GV2RT
    • GV2P
    • GV2LE
      • Mounting location
        front side
        Pole contact composition
        2 NO
        Connections - terminals
      • screw clamp terminals 1 cable(s) 1-2.5 mm²solid
      • screw clamp terminals 2 cable(s) 1-2.5 mm²solid
      • screw clamp terminals 1 cable(s) 0.75-2.5 mm²flexible without cable end
      • screw clamp terminals 2 cable(s) 0.75-2.5 mm²flexible without cable end
      • screw clamp terminals 1 cable(s) 0.75-1.5 mm²flexible with cable end
        • Quantity per set
          set of 10
          [Ui] rated insulation voltage
        • 300 V conforming to UL 508
        • 300 V conforming to CSA C22.2 No 14
        • 250 V conforming to IEC 60947-1
          • [Ue] rated operational voltage
          • 24...240 V AC
          • 24...60 V DC
            • [Ith] conventional free air thermal current
              2.5 A
              Protection type
            • gG fuse 10 A
            • GB2CB06 circuit breaker 10 A
              • Mechanical durability
                100000 cycles
                Minimum switching current
                5 mA
                Minimum switching voltage
                17 V
                Rated operational power in VA
              • 120 VA at 110-120 V AC-15 - electrical durability: 100000 cycles
              • 120 VA at 230-240 V AC-15 - electrical durability: 100000 cycles
              • 48 VA at 24-24 V AC-15 - electrical durability: 100000 cycles
              • 60 VA at 48-48 V AC-15 - electrical durability: 100000 cycles
                • Rated operational power in W
                • 15 W at 48 V DC-13 - electrical durability: 100000 cycles
                • 24 W at 24 V DC-13 - electrical durability: 100000 cycles
                • 9 W at 60 V DC-13 - electrical durability: 100000 cycles
                  • Tightening torque
                    1.4 N.m - on screw clamp terminals
                    Height
                    11 mm
                    Width
                    45 mm
                    Depth
                    29 mm
                    Net weight
                    0.02 kg
                    Compatibility code
                    GVAE
                    Environmental characteristic
                    normal environment
                    Sustainable offer status
                    Green Premium product
                    REACh Regulation
                    Reference contains Substances of Very High Concern above the threshold
                    EU RoHS Directive
                    Pro-active compliance (Product out of EU RoHS legal scope)
                    Mercury free
                    Yes
                    RoHS exemption information
                    Yes
                    China RoHS Regulation
                    Product out of China RoHS scope. Substance declaration for your information
                    Environmental Disclosure
                    ENVPEP111252EN
                    Circularity Profile
                    N/A
                    WEEE
                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                    CALIFORNIA PROPOSITION 65
                    WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov
                    Warranty
                    18 months

                    Documents & downloads

                    hide show
                    Filter items
                    • All

                    • CAD Files and Packs

                    • Product Brochures

                    • Movies

                    • Technical Data Catalogues

                    • Catalog Page

                    • Technical Leaflet

                    • Product Environmental

                    • Installation Instruction

                    • End of Life Manual

                    • Data Bulletin

                    • Handout

                    • Operating Manuals

                    • Specification for Tender

                    • Certificates (MSDS)

                    • eTechPub

                    • Declaration of Conformity

                    • White Paper

                    • Software - Released

                    Frequently Asked Questions

                    hide show

                    What is the IP rating of GVAE20? Would the IP rating of GV2P circuit breaker (IP20) get affected by the addition of Aux contact GVAE20?

                    The IP rating of GVAE20 is IP 20.

                    The IP rating of GV2* with GVAE20 is then IP20. It would not get affected by the addition of the Auxiliary 

                    Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

                    Issue:
                    Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
                     
                    Product Line:

                    Tesys GV Manual Starter and Protectors

                    Environment:
                    TeSys GV, GVA, GV2, GV3P

                    Resolution:
                    These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.