Auxiliary contact
MANUAL STARTER AUX CONTACT 575VAC 1AMP I
Instantaneous auxiliary contact block for GV2
Auxiliary contact
MANUAL STARTER AUX CONTACT 575VAC 1AMP I
Instantaneous auxiliary contact block for GV2

Gv2 GV3 Auxiliary N/O N/O Top

Catalogue Number: GVAE20
Auxiliary contact
MANUAL STARTER AUX CONTACT 575VAC 1AMP I
Instantaneous auxiliary contact block for GV2
Auxiliary contact
MANUAL STARTER AUX CONTACT 575VAC 1AMP I
Instantaneous auxiliary contact block for GV2
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
  • TeSys GV2
  • TeSys GV3
    • Range
      TeSys
      Device short name
      GVAE
      Product or component type
      auxiliary contact block
      Product compatibility
    • GV2L
    • GV3P
    • GV2ME
    • LS1D32
    • GV3L
    • GV2RT
    • GV2P
    • GV2LE
      • Mounting location
        front side
        Pole contact composition
        2 NO
        Connections - terminals
      • screw clamp terminals 1 cable(s) 1-2.5 mm²solid
      • screw clamp terminals 2 cable(s) 1-2.5 mm²solid
      • screw clamp terminals 1 cable(s) 0.75-2.5 mm²flexible without cable end
      • screw clamp terminals 2 cable(s) 0.75-2.5 mm²flexible without cable end
      • screw clamp terminals 1 cable(s) 0.75-1.5 mm²flexible with cable end
        • Quantity per set
          set of 10
          [Ui] rated insulation voltage
        • 300 V conforming to UL 508
        • 300 V conforming to CSA C22.2 No 14
        • 250 V conforming to IEC 60947-1
          • [Ue] rated operational voltage
          • 24...240 V AC
          • 24...60 V DC
            • [Ith] conventional free air thermal current
              2.5 A
              Protection type
            • gG fuse 10 A
            • GB2CB06 circuit breaker 10 A
              • Mechanical durability
                100000 cycles
                Minimum switching current
                5 mA
                Minimum switching voltage
                17 V
                Rated operational power in VA
              • 120 VA at 110-120 V AC-15 - electrical durability: 100000 cycles
              • 120 VA at 230-240 V AC-15 - electrical durability: 100000 cycles
              • 48 VA at 24-24 V AC-15 - electrical durability: 100000 cycles
              • 60 VA at 48-48 V AC-15 - electrical durability: 100000 cycles
                • Rated operational power in W
                • 15 W at 48 V DC-13 - electrical durability: 100000 cycles
                • 24 W at 24 V DC-13 - electrical durability: 100000 cycles
                • 9 W at 60 V DC-13 - electrical durability: 100000 cycles
                  • Tightening torque
                    1.4 N.m - on screw clamp terminals
                    Height
                    11 mm
                    Width
                    45 mm
                    Depth
                    29 mm
                    Net weight
                    0.02 kg
                    Compatibility code
                    GVAE
                    Environmental characteristic
                    normal environment
                    Sustainable offer status
                    Green Premium product
                    REACh Regulation
                    Free of Substances of Very High Concern above the threshold
                    REACh free of SVHC
                    Yes
                    EU RoHS Directive
                    Compliant
                    Mercury free
                    Yes
                    RoHS exemption information
                    Yes
                    China RoHS Regulation
                    Product out of China RoHS scope. Substance declaration for your information
                    Environmental Disclosure
                    ENVPEP111252EN
                    Circularity Profile
                    N/A
                    WEEE
                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                    California proposition 65
                    WARNING: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
                    Warranty
                    18 months

                    Documents & downloads

                    hide show
                    Filter items
                    • All

                    • CAD Files and Packs

                    • Product Brochures

                    • Movies

                    • Technical Data Catalogues

                    • Catalog Page

                    • Technical Leaflet

                    • Product Environmental

                    • Installation Instruction

                    • End of Life Manual

                    • Data Bulletin

                    • Handout

                    • Operating Manuals

                    • Specification for Tender

                    • Certificates (MSDS)

                    • eTechPub

                    • Declaration of Conformity

                    • Marine Certificate

                    • White Paper

                    • Software - Released

                    Frequently Asked Questions

                    hide show

                    What is the IP rating of GVAE20? Would the IP rating of GV2P circuit breaker (IP20) get affected by the addition of Aux contact GVAE20?

                    The IP rating of GVAE20 is IP 20.

                    The IP rating of GV2* with GVAE20 is then IP20. It would not get affected by the addition of the Auxiliary 

                    Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

                    Issue:
                    Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
                     
                    Product Line:

                    Tesys GV Manual Starter and Protectors

                    Environment:
                    TeSys GV, GVA, GV2, GV3P

                    Resolution:
                    These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.

                    Can the GV* starters be used on 50 hertz applications?

                    Issue:
                    GV* Starter for 50/60hz application

                    Product Line:
                    Motor Starters and Protectors

                    Environment:
                    PowerPact™ Manual Starters

                    Resolution:
                    Yes, these starters are rated for 50/60 hertz.

                    This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

                    What is the power consumption of the GVAE1?

                    no power consumption....but contacts are rated to 2.5 amps.....see data sheet
                    https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=gvae1
                    User-added image

                    What would be the part number for an enclosure for the GV2ME20

                    Does the GVAE11 auxilliary contact block fit the GV2ME?

                    The GVAE11 auxilliary contact block fits in the top of the GV2ME and GV2P/L

                    Will the accessories used for the GV3ME06 through GV3ME63 work with the GV3ME80?

                    Product Line:
                    GV3 manual motor starters, IEC

                    Resolution:
                    The standard GV3 accessories will work on this device.

                    Protection Rating for GV2E01

                    Issue:
                    What rating does the GV2E01 give when used with the GV2MC01 or GV2MP01 enclosure

                    Product Line:
                    GV2 Enclosure Accessories

                    Environment:
                    US Product

                    Cause:
                    The IP rating is not specified in the Digest 176

                    Resolution:
                    When used with the GV2MC01 or GV2MP01, this kit will give a IP55 rating.

                    What is the part number to get 2 extra N/C auxillary contacts on to a GV Motor C/B?

                    The part numbers to get 2 extra N/C auxillary contacts on to a GV Motor C/B are - GVAE11 & GVAN11
                    For further information , visit links below:-
                    https://www.schneider-electric.com.au/en/search/GVAE11
                    https://www.schneider-electric.com.au/en/search/GVAN11
                     

                    Do we offer a cable operated handle mechanism for the GV7 starters?

                    Issue:
                    They need to mount the GV7 back inside the enclosure and need a handle mechanism with a cable to operate. 

                    Product line:
                    Tesys GV7 manual motor controller

                    Environment:
                    all

                    Cause:
                    n/a

                    Resolution:
                    The GV7 do not offer a cable operator.  Consider switching to a Powerpact circuit breaker which offers the cable mechanism kits.

                    What type of battery could I use with the Galaxy VS UPS?

                    Issue:
                    What kind of external batteries does the Galaxy VS 3-Phase UPS support?

                    Product line:
                    Galaxy VS

                    Environment:
                    All models, all serial numbers

                    Cause:
                    External Battery Options
                     
                    Resolution:
                    Available with both classic VRLA battery solutions (lead-acid) as well as long-life lithium-ion (Li-ION) battery*.
                     
                    Benefits of Li-ion batteries:
                    • Compact and reliable energy storage
                    • Restore backup time quickly
                    • Protect your load even during repeated power interruptions
                    • Longer lifetime than classic battery solutions- matches service life of Galaxy VS UPS
                    • Higher predictability and manageability thanks to the built-in battery monitoring system
                    (*) contact your local sales representative for availability

                     
                     

                    What is the replacement for a GK2AX10 Side mount Auxilary to suit the GV3L40 circuit breaker?

                    The replacement for a GK2AX10 Side mount Auxilary to suit the GV3L40 circuit breaker is a GVAN11. You can also use a GVAE1 however that is front mount and won't work with extended rotary handles.

                    GV2P disconnect options

                    Issue:
                    What is the product number for a complete through-the-door disconnect device for a GV2P

                    Product Line:
                    GV2P Manual Starters and Protectors

                    Environment:
                    US product

                    Cause:
                    Digest 176 is unclear as to what is a complete mechanism with shaft and handle

                    Resolution:
                    There are three devices which include mechanism, shaft and handle:
                    GV2APN01 has a NEMA 1, 12 rating and is black
                    GV2APN02 has a NEMA 1, 12 rating and is red/yellow
                    GV2APN04 has a NEMA 3R, 4, 4X rating and is red/yellow

                    What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

                    Issue:
                    Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

                    Product Line:
                    Digest 177 Section 18 : Contactors and Starters IEC

                    Environment:
                    Products sold and used in the United States

                    Cause:
                    Spacer required

                    Resolution:
                    Compensation plate catalog number GV1F03, requires 2 pieces snap together.