GVAD0101gp TeSys GV2 Accessories

Gv2 GV3 Auxiliary N/O(Flt) N/O Lhs

Catalogue Number: GVAD1010
GVAD0101gp TeSys GV2 Accessories
Retail
$155.18*
RRP (Inc. GST)

Specifications

hide show
Range of product
  • TeSys GV2
  • TeSys GV3
    • Range
      TeSys
      Device short name
      GVAD
      Product or component type
      auxiliary contact block
      Product compatibility
    • GV2L
    • GV2P
    • GV2RT
    • GV3L
    • GV2LE
    • GV3P
    • GV2ME
      • Mounting location
        left side
        Auxiliary contacts operation
        fault signal 1 NO
        Pole contact composition
        2 NO
        Connections - terminals
      • screw clamp terminals 1 cable(s) 1-2.5 mm²solid
      • screw clamp terminals 2 cable(s) 1-2.5 mm²solid
      • screw clamp terminals 1 cable(s) 0.75-2.5 mm²flexible without cable end
      • screw clamp terminals 2 cable(s) 0.75-2.5 mm²flexible without cable end
      • screw clamp terminals 2 cable(s) 0.75-1.5 mm²flexible with cable end
      • screw clamp terminals 1 cable(s) 0.75-1.5 mm²flexible with cable end
        • [Ui] rated insulation voltage
        • 690 V conforming to IEC 60947-1
        • 300 V conforming to UL 508
        • 300 V conforming to CSA C22.2 No 14
          • [Ue] rated operational voltage
          • 48...690 V AC
          • 24...240 V DC
            • [Ith] conventional free air thermal current
            • 6 A
            • 2.5 A for fault signalling
              • Protection type
              • GB2CB... circuit breaker
              • gG fuse 10 A
                • Mechanical durability
                  100000 cycles
                  Minimum switching current
                  5 mA
                  Minimum switching voltage
                  17 V
                  Rated operational power in VA
                • 300 VA at 48-48 V AC-15 - electrical durability: 100000 cycles
                • 414 VA at 690-690 V AC-15 - electrical durability: 100000 cycles
                • 500 VA at 110-127 V AC-15 - electrical durability: 100000 cycles
                • 500 VA at 500-500 V AC-15 - electrical durability: 100000 cycles
                • 650 VA at 440-440 V AC-15 - electrical durability: 100000 cycles
                • 720 VA at 230-240 V AC-15 - electrical durability: 100000 cycles
                • 850 VA at 380-415 V AC-15 - electrical durability: 100000 cycles
                • 36 VA at 24-24 V AC-14 - electrical durability: 1000 cycles
                • 48 VA at 48-48 V AC-14 - electrical durability: 1000 cycles
                • 72 VA at 110-127 V AC-14 - electrical durability: 1000 cycles
                  • Rated operational power in W
                  • 120 W at 240 V DC-13 - electrical durability: 100000 cycles
                  • 140 W at 110 V DC-13 - electrical durability: 100000 cycles
                  • 140 W at 24 V DC-13 - electrical durability: 100000 cycles
                  • 180 W at 60 V DC-13 - electrical durability: 100000 cycles
                  • 240 W at 48 V DC-13 - electrical durability: 100000 cycles
                  • 15 W at 48 V DC-13 - electrical durability: 1000 cycles
                  • 24 W at 24 V DC-13 - electrical durability: 1000 cycles
                  • 9 W at 60 V DC-13 - electrical durability: 1000 cycles
                    • Tightening torque
                      1.4 N.m - on screw clamp terminals
                      Height
                      89 mm
                      Width
                      9.3 mm
                      Depth
                      66 mm
                      Net weight
                      0.055 kg
                      Compatibility code
                      GVAD
                      Environmental characteristic
                      normal environment
                      Sustainable offer status
                      Green Premium product
                      REACh Regulation
                      Free of Substances of Very High Concern above the threshold
                      REACh free of SVHC
                      Yes
                      EU RoHS Directive
                      Compliant
                      Toxic heavy metal free
                      Yes
                      Mercury free
                      Yes
                      RoHS exemption information
                      Yes
                      China RoHS Regulation
                       Pro-active China RoHS declaration (out of China RoHS legal scope)
                      Environmental Disclosure
                      ENVPEP111252EN
                      WEEE
                      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                      Warranty
                      18 months

                      Documents & downloads

                      hide show
                      Filter items
                      • All

                      • CAD Files and Packs

                      • Product Brochures

                      • Technical Data Catalogues

                      • Product Environmental

                      • Installation Instruction

                      • eTechPub

                      Frequently Asked Questions

                      hide show

                      What is the fault aux contact for a GV2 which has a normally open contact

                       The part code GVAD1010

                      Can the GVAD0101 be stacked?

                      Issue:
                      Can you mount multiple GVAD0101 in tandem?

                      Product Line:
                      GV2, GV3 manual motor protectors

                      Resolution:
                      Yes, You can stack up to 2 max

                      Can the handle or knob (GS2AH110 etc..) be mounted directly to a GS1DDU3?

                      Issue:
                      GS2AH handle or knob  mounting directly to a GS1DDU3?

                      Product Line: 
                      GS2

                      Environment:
                      GS1DDU3

                      Cause:
                      Wants the handle or knob  (GS2AH110 etc..) be mounted directly to GS1DDU3.

                      Resolution:
                      No, but they can used an internal handle kit - Part number GS1AD010

                      What is the operation of the GV2AD fault signalling contacts of the GV2 circuit-breakers?

                      GV2ME, GV2P, GV2L, GV2LE, GV3P and GV3L circuit-breakers can be fitted with the following optional fault indicating contact blocks:
                       

                      GVAD0110
                      GVAD0101
                      GVAD1010
                      GVAD1001

                      These blocks comprise of fault signalling contacts and instantaneous auxiliary contacts

                      GVAD0110

                      A N/O instantaneous auxiliary contact (terminals 53-54), closed when the device is energized and open when the device is de-energized

                      A N/C fault signalling contact (terminals 95-96), closed if there is no fault, open when a fault (magnetic or thermal) occurs. 

                      GVAD0101

                      A N/C instantaneous auxiliary contact (terminals 51-52), closed when the device is de-energised and open when the device is energised.

                      A N/C fault signalling contact (terminals 95-96), closed if there is no fault, open when a fault (magnetic or thermal) occurs. 

                      GVAD1010 

                      A N/O instantaneous auxiliary contact (terminals 53-54), closed when the device is energized and open when the device is de-energized.

                      A N/O fault signalling contact (terminals 97-98), open if there is no fault, closed when a fault (magnetic or thermal) occurs. 
                       

                      GVAD1001

                      A N/C instantaneous auxiliary contact (terminals 51-52), closed when the device is de-energized and open when the device is energized.

                      A N/O fault signalling contact (terminals 97-98), open if there is no fault, closed when a fault (magnetic or thermal) occurs. 
                       


                      The instantaneous auxiliary contact test is performed by creating a state of transition of the handle actuator between the de-energized position and the energized position.

                      The fault contact test is performed by pressing the test button when the handle actuator is in the closed position.

                      Are EasyPact CVS circuit breakers for sale in the USA or Canada?

                      Product Line:
                      EasyPact CVS circuit breakers

                      Cause:
                      This breaker is popular overseas and there is interest in the US

                      Resolution:
                      There are no plans for a general release of the EasyPact CVS circuit breaker line in North America.