GVAD0101gp TeSys GV2 Accessories

Gv2 GV3 Auxiliary N/C(Flt) N/O Lhs

Catalogue Number: GVAD0110
GVAD0101gp TeSys GV2 Accessories
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
  • TeSys GV3
  • TeSys GV2
    • Range
      TeSys
      Device short name
      GVAD
      Product or component type
      auxiliary contact block
      Product compatibility
    • GV2ME
    • GV2L
    • GV3P
    • GV2P
    • GV3L
    • GV2LE
    • GV2RT
      • Mounting location
        left side
        Auxiliary contacts operation
        fault signal 1 NC
        Pole contact composition
        1 NO + 1 NC
        Connections - terminals
      • screw clamp terminals 1 cable(s) 1-2.5 mm²solid
      • screw clamp terminals 2 cable(s) 1-2.5 mm²solid
      • screw clamp terminals 1 cable(s) 0.75-2.5 mm²flexible without cable end
      • screw clamp terminals 2 cable(s) 0.75-2.5 mm²flexible without cable end
      • screw clamp terminals 2 cable(s) 0.75-1.5 mm²flexible with cable end
      • screw clamp terminals 1 cable(s) 0.75-1.5 mm²flexible with cable end
        • [Ui] rated insulation voltage
        • 690 V conforming to IEC 60947-1
        • 300 V conforming to UL 508
        • 300 V conforming to CSA C22.2 No 14
          • [Ue] rated operational voltage
          • 48...690 V AC
          • 24...240 V DC
            • [Ith] conventional free air thermal current
            • 6 A
            • 2.5 A for fault signalling
              • Protection type
              • GB2CB... circuit breaker
              • gG fuse 10 A
                • Mechanical durability
                  100000 cycles
                  Minimum switching current
                  5 mA
                  Minimum switching voltage
                  17 V
                  Rated operational power in VA
                • 300 VA at 48-48 V AC-15 - electrical durability: 100000 cycles
                • 414 VA at 690-690 V AC-15 - electrical durability: 100000 cycles
                • 500 VA at 110-127 V AC-15 - electrical durability: 100000 cycles
                • 500 VA at 500-500 V AC-15 - electrical durability: 100000 cycles
                • 650 VA at 440-440 V AC-15 - electrical durability: 100000 cycles
                • 720 VA at 230-240 V AC-15 - electrical durability: 100000 cycles
                • 850 VA at 380-415 V AC-15 - electrical durability: 100000 cycles
                • 36 VA at 24-24 V AC-14 - electrical durability: 1000 cycles
                • 48 VA at 48-48 V AC-14 - electrical durability: 1000 cycles
                • 72 VA at 110-127 V AC-14 - electrical durability: 1000 cycles
                  • Rated operational power in W
                  • 120 W at 240 V DC-13 - electrical durability: 100000 cycles
                  • 140 W at 110 V DC-13 - electrical durability: 100000 cycles
                  • 140 W at 24 V DC-13 - electrical durability: 100000 cycles
                  • 180 W at 60 V DC-13 - electrical durability: 100000 cycles
                  • 240 W at 48 V DC-13 - electrical durability: 100000 cycles
                  • 15 W at 48 V DC-13 - electrical durability: 1000 cycles
                  • 24 W at 24 V DC-13 - electrical durability: 1000 cycles
                  • 9 W at 60 V DC-13 - electrical durability: 1000 cycles
                    • Tightening torque
                      1.4 N.m - on screw clamp terminals
                      Height
                      89 mm
                      Width
                      9.3 mm
                      Depth
                      66 mm
                      Net weight
                      0.055 kg
                      Compatibility code
                      GVAD
                      Environmental characteristic
                      normal environment
                      Sustainable offer status
                      Green Premium product
                      REACh Regulation
                      Free of Substances of Very High Concern above the threshold
                      REACh free of SVHC
                      Yes
                      EU RoHS Directive
                      Compliant
                      Toxic heavy metal free
                      Yes
                      Mercury free
                      Yes
                      RoHS exemption information
                      Yes
                      China RoHS Regulation
                       Pro-active China RoHS declaration (out of China RoHS legal scope)
                      Environmental Disclosure
                      ENVPEP111252EN
                      WEEE
                      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                      Warranty
                      18 months

                      Documents & downloads

                      hide show
                      Filter items
                      • All

                      • CAD Files and Packs

                      • Product Brochures

                      • Technical Data Catalogues

                      • Product Environmental

                      • Installation Instruction

                      • eTechPub

                      Frequently Asked Questions

                      hide show

                      Can the GVAD0101 be stacked?

                      Issue:
                      Can you mount multiple GVAD0101 in tandem?

                      Product Line:
                      GV2, GV3 manual motor protectors

                      Resolution:
                      Yes, You can stack up to 2 max

                      What is the fault aux contact for a GV2 which has a normally open contact

                       The part code GVAD1010

                      How does the GAVD0110 auxiliary contact work?

                       Issue:
                      How does the GAVD0110 auxiliary contact work?

                      Product line:
                      Tesys GV manual starters

                      Environment:
                      Auxiliary contacts

                      Cause:
                      Contacts do not appear to be working properly.

                      Resolution:
                      The GVAD** can only be installed on left side of product and the GV2 must be in OFF position when mounting.
                       
                      The GVAD0110 has 2 different contacts
                      One is fault signaling contact (terminals 95/96) NC contact and the second is only standard auxiliary NO contact (terminals 53/54 ).
                       
                      Fault signaling defect contact should be always in close position excepted when there is fault on GV2 ( short circuit or overload ) at this time contact open.
                      This fault signaling defect contact is not related to ON/OFF position of GV2’s but to reset back to NC the device must be switched back to the ON position. 
                       
                      Auxiliary contact report the ON/OFF position of GV2’s.
                      This Auxiliary NO contact is on Open when GV2 is on OFF position and close when GV2 is ON position.

                      Can the handle or knob (GS2AH110 etc..) be mounted directly to a GS1DDU3?

                      Issue:
                      GS2AH handle or knob  mounting directly to a GS1DDU3?

                      Product Line: 
                      GS2

                      Environment:
                      GS1DDU3

                      Cause:
                      Wants the handle or knob  (GS2AH110 etc..) be mounted directly to GS1DDU3.

                      Resolution:
                      No, but they can used an internal handle kit - Part number GS1AD010