Specifications

Design

Sustainable offer status

Green Premium product

Warranty

18 months

Range

TeSys

Product or component type

circuit breaker

Device application

motor protection

Physical

Circularity Profile

ENVEOLI1704004EN

Environmental Disclosure

ENVPEP1704004EN

Mercury free

Yes

REACh Regulation

Free of Substances of Very High Concern above the threshold

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

EU RoHS Directive

Compliant

RoHS exemption information

Yes

Protection type

  • short-circuit
  • ground fault protection
  • phase loss
  • overload
  • short time short-circuit protection
  • phase unbalance
    • [Ue] rated operational voltage

      690 V AC 50/60 Hz conforming to IEC 60947-2

      [In] rated current

      12.5 A

      Mechanical durability

      40000 cycles

      Electrical durability

    • 40000 cycles for AC-3 at 440 V In/2
    • 40000 cycles for AC-3 at 440 V In
      • Control type

        toggle

        Local signalling

      • flashing LED (green) for ready
      • LED (red) for alarm (T° >95%)
      • green indicator for presence of auxiliary contacts
        • Standards

        • EN/IEC 60947-4-1
        • EN/IEC 60947-2
        • UL 60947-4-1
        • CSA C22.2 No 60947-4-1
          • Product certifications

          • IEC
          • UL
          • CSA
          • CCC
          • EAC
          • ATEX
          • EU-RO MR
            • Mounting mode

            • by clips
            • by screws
              • Mounting support

              • 35 mm symmetrical DIN rail
              • 75 mm symmetrical DIN rail
              • plate
                • Connections - terminals

                • top 1 EverLink BTR screw connectors wire size 1.5-70 mm², solid
                • top 1 EverLink BTR screw connectors wire size 1.5-50 mm², flexible
                • bottom 1 EverLink BTR screw connectors wire size 2.5-95 mm², solid
                • bottom 1 EverLink BTR screw connectors wire size 2.5-70 mm², flexible
                  • Wire stripping length

                    20 mm

                    Width

                    81 mm

                    Height

                    155 mm

                    Depth

                    116 mm

                    Net weight

                    1.45 kg

                    Ambient air temperature for storage

                    -50-85 °C

                    Ambient air temperature for operation

                    -25-70 °C

                    IP degree of protection

                    IP40 front face conforming to IEC 60529

                    IK degree of protection

                    IK07 conforming to IEC 62262

                    Others

                    Halogen content performance

                    Halogen free plastic parts product

                    Package 1 Height

                    11 cm

                    Package 1 Length

                    22 cm

                    Package 1 Weight

                    1.65 kg

                    Package 1 width

                    16.5 cm

                    Package 2 Height

                    30 cm

                    Package 2 Length

                    40 cm

                    Package 2 Weight

                    14 kg

                    Package 2 width

                    30 cm

                    Number of Units in Package 1

                    1

                    Number of Units in Package 2

                    5

                    Unit Type of Package 1

                    PCE

                    Unit Type of Package 2

                    S03

                    WEEE

                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                    PVC free

                    Yes

                    Product name

                    TeSys GV4

                    Device short name

                    GV4PE

                    Utilisation category

                    category A

                    Suitability for isolation

                    yes conforming to IEC 60947-1

                    Poles description

                    3P

                    Trip unit technology

                  • electronic
                  • thermal-magnetic
                    • Magnetic tripping current

                      212-212 A

                      [Isd] short-time pick-up adjustment range

                      13 x Ir

                      Thermal protection adjustment range

                      5-12.5 A

                      Motor tripping class

                    • 10
                    • 20
                      • Phase failure sensitivity

                        yes conforming to IEC 60947-4-1

                        Breaking capacity

                      • Icu 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
                      • Icu 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
                      • Icu 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
                      • Icu 15 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
                      • 65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
                      • 65 kA at 240 V AC 50/60 Hz conforming to UL 60947
                      • 35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
                      • Icu 8 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
                      • Icu 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
                      • 18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
                        • [Ics] rated service breaking capacity

                        • 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
                        • 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
                        • 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
                        • 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
                        • 15 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
                        • 2 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
                          • [Uimp] rated impulse withstand voltage

                            [Ui] rated insulation voltage

                            800 V conforming to IEC 60947-2

                            Motor power kW

                          • 3-3 kW at 400...415 V AC 50/60 Hz
                          • 3-3 kW at 500 V AC 50/60 Hz
                          • 4-4 kW at 500 V AC 50/60 Hz
                          • 5.5-5.5 kW at 660...690 V AC 50/60 Hz
                          • 7.5-7.5 kW at 660...690 V AC 50/60 Hz
                          • 4-4 kW at 400...415 V AC 50/60 Hz
                          • 5.5-5.5 kW at 400...415 V AC 50/60 Hz
                          • 5.5-5.5 kW at 500 V AC 50/60 Hz
                          • 7.5-7.5 kW at 500 V AC 50/60 Hz
                          • 9-9 kW at 660...690 V AC 50/60 Hz
                          • 11-11 kW at 660...690 V AC 50/60 Hz
                            • Rotary handle padlocking

                              with a lock accessory

                              Number of slots

                            • 1 slot(s) for alarm switch for fault signalling contact, plug-in
                            • 1 slot(s) for voltage release for electrical remote tripping, plug-in
                            • 1 slot(s) for auxiliary switch for open/close contact, plug-in
                              • Quality labels

                                CE

                                Connection pitch

                                27 mm

                                Tightening torque

                              • 9-9 N.m for 16-95 mm²
                              • 5-5 N.m for 1.5-10 mm²
                                • Operating altitude

                                • 0...2000 m without derating
                                • 2000...5000 m with derating
                                  • Pollution degree

                                    3 conforming to IEC 60947-1

                                    Tropicalisation

                                    2 conforming to IEC 68-2

                                    Mechanical robustness

                                  • vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
                                  • vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
                                  • shocks: 15 gn 11 ms conforming to IEC 60068-2-27
                                    • Show all specifications

                                      Frequently Asked Questions

                                      hide show

                                      Will the accessories used for the GV3ME06 through GV3ME63 work with the GV3ME80?

                                      Product Line:
                                      GV3 manual motor starters, IEC

                                      Resolution:
                                      The standard GV3 accessories will work on this device.

                                      Will the Tesys GV2ME starters install into old style enclosures designed for the GV2M, GV2MC01 and GV2MC02 enclosures?

                                      Issue:
                                      GV2ME compatibility with old enclosure 

                                      Product Line:

                                      Motor Starters and Protectors

                                      Environment:
                                      TeSys™ GV Manual Starters and Protectors
                                       
                                      Resolution:
                                      No, Order new enclosures using the same catalog numbers. The current enclosure has an updated DIN attachement which will accept the Tesys GV2ME starters but will not accept the old GV2M starters.