Quantcast

Motor Breaker GV4P Thermal/Magnetic 115A 25kA Lug Terminal

Motor Breaker GV4P Thermal/Magnetic 115A 25kA Lug Terminal

Motor Breaker GV4P Thermal/Magnetic 115A 25kA Lug Terminal

Item Number: GV4P115B6

Retail
$1,936.17
RRP (Inc. GST)

Product Dimensions

Width icon

Width81 mm

Height icon

Height155 mm

Depth icon

Depth165 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Product or component type

circuit breaker

Device application

motor protection

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Protection type

  • short-circuit
  • phase loss
  • overload
  • phase unbalance
  • ground fault protection
  • short time short-circuit protection
    • [Ue] rated operational voltage

      690 V AC 50/60 Hz conforming to IEC 60947-2

      [In] rated current

      115 A

      Mechanical durability

      40000 cycles

      Electrical durability

    • 10000 cycles for AC-3 at 440 V In/2
    • 5000 cycles for AC-3 at 440 V In
      • Control type

        rotary handle

        Local signalling

      • flashing LED (green) for ready
      • LED (red) for alarm (T° >95%)
      • green indicator for presence of auxiliary contacts
        • Standards

        • EN/IEC 60947-4-1
        • EN/IEC 60947-2
        • UL 60947-4-1
        • CSA C22.2 No 60947-4-1
          • Product certifications

          • IEC
          • UL
          • CSA
          • CCC
          • EAC
          • ATEX
          • EU-RO MR
            • Mounting mode

            • by screws
            • by clips
              • Mounting support

              • plate
              • 35 mm symmetrical DIN rail
              • 75 mm symmetrical DIN rail
                • Connections - terminals

                  lugs-ring terminals

                  Width

                  81 mm

                  Height

                  155 mm

                  Depth

                  165 mm

                  Net weight

                  1.6 kg

                  Ambient air temperature for storage

                  -50-85 °C

                  Ambient air temperature for operation

                  -25-70 °C

                  IP degree of protection

                  IP40 front face conforming to IEC 60529

                  IK degree of protection

                  IK07 conforming to IEC 62262

                  REACh Regulation

                  Free of Substances of Very High Concern above the threshold

                  EU RoHS Directive

                  Compliant

                  Mercury free

                  Yes

                  RoHS exemption information

                  Yes

                  China RoHS Regulation

                  Product out of China RoHS scope. Substance declaration for your information

                  Environmental Disclosure

                  ENVPEP1704004EN

                  Circularity Profile

                  ENVEOLI1704004EN

                  Others

                  Package 1 Height

                  21 cm

                  Package 1 Length

                  22 cm

                  Package 1 width

                  10.5 cm

                  Product name

                  TeSys GV4

                  Device short name

                  GV4P

                  Utilisation category

                  category A

                  Suitability for isolation

                  yes conforming to IEC 60947-1

                  Poles description

                  3P

                  Trip unit technology

                • electronic
                • thermal-magnetic
                  • Magnetic tripping current

                    1955-1955 A

                    [Isd] short-time pick-up adjustment range

                    13 x Ir

                    Thermal protection adjustment range

                    65-115 A

                    Motor tripping class

                  • 10
                  • 20
                    • Phase failure sensitivity

                      yes conforming to IEC 60947-4-1

                      Breaking capacity

                    • Icu 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
                    • Icu 25 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
                    • Icu 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
                    • Icu 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
                    • 35 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
                    • 35 kA at 240 V AC 50/60 Hz conforming to UL 60947
                    • 18 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
                    • 14 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
                      • [Ics] rated service breaking capacity

                      • 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
                      • 25 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
                      • 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
                      • 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
                        • [Uimp] rated impulse withstand voltage

                          [Ui] rated insulation voltage

                          800 V conforming to IEC 60947-2

                          Motor power kW

                        • 37-37 kW at 400...415 V AC 50/60 Hz
                        • 45-45 kW at 400...415 V AC 50/60 Hz
                        • 55-55 kW at 400...415 V AC 50/60 Hz
                        • 45-45 kW at 500 V AC 50/60 Hz
                        • 55-55 kW at 500 V AC 50/60 Hz
                        • 75-75 kW at 500 V AC 50/60 Hz
                        • 75-75 kW at 660...690 V AC 50/60 Hz
                        • 90-90 kW at 660...690 V AC 50/60 Hz
                        • 110-110 kW at 660...690 V AC 50/60 Hz
                          • Rotary handle padlocking

                            padlock in OFF or ON position

                            Number of slots

                          • 1 slot(s) for alarm switch for fault signalling contact, plug-in
                          • 1 slot(s) for voltage release for electrical remote tripping, plug-in
                          • 1 slot(s) for auxiliary switch for open/close contact, plug-in
                            • Quality labels

                              CE

                              Connection pitch

                              27 mm

                              Tightening torque

                            • 9-9 N.m for 16-95 mm²
                            • 5-5 N.m for 1.5-10 mm²
                              • Operating altitude

                              • 0...2000 m without derating
                              • 2000...5000 m with derating
                                • Pollution degree

                                  3 conforming to IEC 60947-1

                                  Tropicalisation

                                  2 conforming to IEC 68-2

                                  Mechanical robustness

                                • vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
                                • vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
                                • shocks: 15 gn 11 ms conforming to IEC 60068-2-27
                                  • Package 1 Weight

                                    1.602 kg

                                    WEEE

                                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                                    PVC free

                                    Yes

                                    Halogen content performance

                                    Halogen free plastic parts product
                                    Show all specifications

                                    Frequently Asked Questions

                                    hide show

                                    What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

                                    Issue:
                                    Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

                                    Product Line:
                                    Contactors and Starters IEC

                                    Environment:
                                    Tesys D contactors and GV manual starters

                                    Cause:
                                    Spacer required

                                    Resolution:
                                    Compensation plate catalog number GV1F03, requires 2 pieces snap together.

                                    What is the part code for a contact block for GV3P40 n/o n/c to fit the left side of the Motor Starter?

                                    The Part code is GVAN11
                                    See link for data sheet:
                                    https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=GVAN11

                                    What is the part number to get 2 extra N/C auxillary contacts on to a GV Motor C/B?

                                    The part numbers to get 2 extra N/C auxillary contacts on to a GV Motor C/B are - GVAE11 & GVAN11
                                    For further information , visit links below:-
                                    https://www.schneider-electric.com.au/en/search/GVAE11
                                    https://www.schneider-electric.com.au/en/search/GVAN11
                                     

                                    Will the Compact NSX breaker be for sale in the USA or Canada?

                                    Issue:
                                    Where can I buy a Compact NSX breaker?

                                    Product Line:
                                    Circuit Breakers

                                    Cause:
                                    This breaker is popular overseas and there is interest in the US

                                    Resolution:
                                    There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

                                    If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

                                    For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
                                    https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page

                                    What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                    Issue:
                                    Identifying maximum voltage of an LC1D contactor

                                    Product Line:
                                    TeSys D Contactors

                                    Environment:
                                    IEC contactors and starters used in North America

                                    Cause:
                                    n/a

                                    Resolution:
                                    IThe maximum voltage per UL and CSA is 600VAC.