S Power Busbar for Side By Side Mountin

S Power Busbar for Side By Side Mountin

S Power Busbar for Side By Side Mountin

Item Number: GV3S

Retail
$66.76
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

  • TeSys D
  • TeSys GV3
    • Range

      TeSys

      Product or component type

      comb busbar

      Product compatibility

    • GV3P
    • LC1D40A...D65A
    • GV3L
      • Warranty

        18 months

        Physical

        Range compatibility

      • TeSys D
      • TeSys GV3
        • Net weight

          0.104 kg

          EU RoHS Directive

          Compliant

          Mercury free

          Yes

          RoHS exemption information

          Yes

          China RoHS Regulation

          Product out of China RoHS scope. Substance declaration for your information

          Others

          Accessory / separate part category

          connection accessory

          Poles description

          3P

          Product specific application

          S-shape busbar

          Package 1 Weight

          0.12 kg

          Package 1 Height

          0.8 dm

          Package 1 width

          1.2 dm

          Package 1 Length

          2.4 dm

          WEEE

          The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
          Show all specifications

          Documents & downloads

          hide show
          Filter items
          • All

          • Product Brochures

          • Technical Data Catalogues

          • Installation Instruction

          • Data Bulletin

          Frequently Asked Questions

          hide show

          Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

          Issue:
          Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
           
          Product Line:

          Tesys GV Manual Starter and Protectors

          Environment:
          TeSys GV, GVA, GV2, GV3P

          Resolution:
          These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.

          Video: How to Mount a GV3P Motor Starter/Protector to a LC1D Contactor with Everlink Terminals

          Issue:
          How GV3P and LC1D contacto with Evelink connect to each other 

          Product Line: 
          Contact and Starters - IEC  

          Environment:
          LC1D Tesys D Contactors, GV3P Manual Motor Starter/PRotector

          Resolution:
          Take your GV3P and remove the Everlink terminals from the base. Line up the exposed terminals with the top of the contactor so that they mate together. Use an Allen Wrench to secure the GV3P tight to the contactor.

          Will the accessories used for the GV3ME06 through GV3ME63 work with the GV3ME80?

          Product Line:
          GV3 manual motor starters, IEC

          Resolution:
          The standard GV3 accessories will work on this device.

          What is the significance of two arrows on the knob of Tesys GV3P Current Setting Dial.

          The first black arrow needs to be set at the rated current of Motor, when Tesys GV3 MPCB is used with contactor separately mounted or not used at all.
           
          The second white arrow needs be set at rated current of Motor, when the Tesys GV3 MPCB and contactor are used in combination. This setting gives allowance for the heat dissipation in the thermal characteristics of MPCB due to the combined use of the Tesys GV3P and Tesys LC1D at the rated current.
           
          See below diagram for clarity.


          Is there a through the door operating mechanism for the GV3P manual starters?

          Issue: 
          Is there a through the door operating mechanism for the GV3P manual starters?

          Product Line:
          IEC Contactors and Starters

          Environment:
          GV3P Manual Starters and Protectors

          Cause:
          Product selection/feature
           
          Resolution:
          There are three different through the door operating mechanisms for the GV3P. There is the GV3APN01 which is rated
          NEMA 1 and 12 in black with trip indication; the GV3APN02 which is also NEMA 1 and 12 in red/yellow with trip indication,
          and the GV3APN04 which is NEMA 4/X red/yellow without trip indication.
           

          Is it permissible to electrically reverse feed the TeSys range of MPCB.

          Yes, it is possible to reverse feed the Power in the TeSys GV range of Motor protection circuit breaker (MPCB). 

          It means you can connect the incoming line to the terminals T and the load to the terminals L and vice versa.
           
          However, for safety purpose, it is necessary to indicate these connections on the MPCB clearly.

          What is the current rating of the GV1G02?

          Issue:
          GV1G02 electrical ratings

          Product Line:
          GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Selection

          Environment:
          Additional GV2 Wiring Accessories

          Resolution:
          25 amp maximum

          How many of GVAN11 side Auxiliary can be put on GV3 circuit breakers?

          Maximum of 2 sides mounted Auxiliary can be used with GV3 circuit breaker.
           

          Are GV manual starters suitable for tap conductor protection?

          Issue:
          GV manual starter tap conductor protection

          Product Line:
          Tesys GV Family

          Environment:
          GV2 GV3

          Resolution:
          GV2P & GV3P manual starter are suitable for tap conductor protection. 

           

          What is the part number for the replacement GV3 thermal Magnetic C/B - GV3ME63/40?

          The part number for the replacement GV3 Thermal Magnetic C/B - GV3ME63/40 is - GV3P50 or GV3P65

          For further information, visit links below:-
          https://www.schneider-electric.com.au/en/search/GV3P50
          https://www.schneider-electric.com.au/en/search/GV3P65
          User-added image
          User-added image

           

          What is the part number for the 3 tap off comb for the GV3

           The part code is GV3G364

          Do the GV manual motor starters have repair parts?

           

          Issue:     
          Do the GV manual motor starters have repair parts?
          Product Line:
          GV manual motor protectors
          Environment:
          Products sold and used in the United States
          Cause:
          Need replacement parts for a GV2P GV2ME or GV3P starter

          Resolution:

          The GV line of manual starters does not have repair parts, the manual motor protector will have to be replaced in it's entirety.