TeSys GV2 Motor Circuit Breaker, Thermal Magnetic, 0.16¦0.25 A

TeSys GV2 Motor Circuit Breaker, Thermal Magnetic, 0.16¦0.25 A

TeSys GV2 Motor Circuit Breaker, Thermal Magnetic, 0.16¦0.25 A

Item Number: GV2P02

Retail
$510.65
RRP (Inc. GST)

Product Dimensions

Width icon

Width45 mm

Height icon

Height89 mm

Depth icon

Depth97 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Range of product

TeSys GV2

Product or component type

circuit breaker

Device application

motor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Fixing mode

  • 35 mm symmetrical DIN rail: clipped
  • panel: screwed (with 2 x M4 screws)
    • Control type

      rotary knob

      [In] rated current

      0.25 A

      [Ue] rated operational voltage

      690 V AC 50/60 Hz conforming to IEC 60947-2

      Mechanical durability

      100000 cycles

      Electrical durability

      100000 cycles for AC-3 at 440 V

      Height

      89 mm

      Width

      45 mm

      Depth

      97 mm

      Standards

    • EN/IEC 60947-2
    • EN/IEC 60947-4-1
    • UL 60947-4-1
    • CSA C22.2 No 60947-4-1
      • Product certifications

      • IECEE CB Scheme
      • UL
      • CSA
      • CCC
      • EAC
      • ATEX
      • BV
      • LROS (Lloyds register of shipping)
      • DNV-GL
      • RINA
        • IP degree of protection

          IP20 conforming to IEC 60529

          IK degree of protection

          IK04

          Ambient air temperature for operation

          -20-60 °C

          Ambient air temperature for storage

          -40-80 °C

          REACh Regulation

          Free of Substances of Very High Concern above the threshold

          EU RoHS Directive

          Compliant

          Mercury free

          Yes

          RoHS exemption information

          Yes

          China RoHS Regulation

          Product out of China RoHS scope. Substance declaration for your information

          Environmental Disclosure

          ENVPEP121004EN

          California proposition 65

          WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

          Others

          Product name

          TeSys GV2

          Device short name

          GV2P

          Trip unit technology

          thermal-magnetic

          Poles description

          3P

          Network type

          AC

          Utilisation category

        • AC-3 conforming to IEC 60947-4-1
        • category A conforming to IEC 60947-2
          • Network frequency

            50/60 Hz conforming to IEC 60947-4-1

            Operating position

            any position

            Motor power kW

            0.06-0.06 kW at 400/415 V AC 50/60 Hz

            Breaking capacity

          • 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
          • 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
          • 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
          • 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
          • 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
            • [Ics] rated service short-circuit breaking capacity

            • 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
              • Trip unit rating

                0.16-0.25 A

                Magnetic tripping current

                2.4-2.4 A

                [Ui] rated insulation voltage

                690 V AC 50/60 Hz conforming to IEC 60947-2

                [Ith] conventional free air thermal current

                0.25 A conforming to IEC 60947-4-1

                [Uimp] rated impulse withstand voltage

                Power dissipation per pole

                2.5 W

                Maximum operating rate

                25 cyc/h

                Rated duty

                continuous conforming to IEC 60947-4-1

                Direct connector

                without

                Tightening torque

                1.7 N.m on screw clamp terminals

                Suitability for isolation

                yes conforming to IEC 60947-1

                Phase failure sensitivity

                yes conforming to IEC 60947-4-1

                Compatibility code

                GV2P

                Protective treatment

                TH

                Fire resistance

                960 °C conforming to IEC 60695-2-1

                Operating altitude

                2000 m

                Unit Type of Package 1

                PCE

                Number of Units in Package 1

                1

                Package 1 Weight

                265 g

                Package 1 Height

                4.8 cm

                Package 1 width

                9.3 cm

                Package 1 Length

                10 cm

                Unit Type of Package 2

                S02

                Number of Units in Package 2

                20

                Package 2 Weight

                5.619 kg

                Package 2 Height

                15 cm

                Package 2 width

                30 cm

                Package 2 Length

                40 cm

                Unit Type of Package 3

                P06

                Number of Units in Package 3

                320

                Package 3 Weight

                105.38 kg

                Package 3 Height

                77 cm

                Package 3 width

                80 cm

                Package 3 Length

                60 cm

                WEEE

                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                Show all specifications

                Documents & downloads

                hide show
                Filter items
                • All

                • CAD Files and Packs

                • Product Brochures

                • Technical Data Catalogues

                • Installation Instruction

                • Data Bulletin

                • Product Environmental

                • Technical Drawing

                • Declaration of Conformity

                • eTechPub

                • Certificates (MSDS)

                Frequently Asked Questions

                hide show

                GV2P disconnect options

                Issue:
                What is the product number for a complete through-the-door disconnect device for a GV2P

                Product Line:
                IEC Contactors and Starters

                Environment:
                GV2P Manual Starters and Protectors

                Resolution:
                There are three devices which include mechanism, shaft and handle:
                GV2APN01 has a NEMA 1, 12 rating and is black
                GV2APN02 has a NEMA 1, 12 rating and is red/yellow
                GV2APN04 has a NEMA 3R, 4, 4X rating and is red/yellow