Will the Tesys GV2ME starters install into old style enclosures designed for the GV2M, GV2MC01 and GV2MC02 enclosures?
Issue:
GV2ME compatibility with old enclosure
Product Line:
Motor Starters and Protectors
Environment:
TeSys™ GV Manual Starters and Protectors
Resolution:
No, Order new enclosures using the same catalog numbers. The current enclosure has an updated DIN attachement which will accept the Tesys GV2ME starters but will not accept the old GV2M starters.
Are explosion proof enclosures available for GV manual motor starters.
Issue:
NEMA 7/9 rated enclosure for GV manual motor starters
Product Line:
Tesys GV Motor Starters and Protectors
Environment:
TeSys™ GV Manual Starters and Protectors
Resolution:
No hazardous duty enclosures are available for the GV product line.
For explosion proof applications consider the Class 2510 Type M or Type T offering.
Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?
Issue:
Mounting adaptor for GV2 and LC1D contactor
Product Line:
Motor Starters and Protectors
Environment:
TeSys GV Manual Starter and Protectors
Tesys D Contactors
Resolution:
The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.
Can the GV* starters be used on 50 hertz applications?
Issue:
GV* Starter for 50/60hz application
Product Line:
Motor Starters and Protectors
Environment:
PowerPact™ Manual Starters
Resolution:
Yes, these starters are rated for 50/60 hertz.
This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.
What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?
Issue:
Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination
Product Line:
Contactors and Starters IEC
Environment:
Tesys D contactors and GV manual starters
Cause:
Spacer required
Resolution:
Compensation plate catalog number GV1F03, requires 2 pieces snap together.
Is a padlocking device available for the GV2MC** type enclosures?
Issue:
Padlocking device for GV2MC Enclosures
Product Line:
TeSys GV2 Manual Starters and Protectors
Environment:
n/a
Resolution:
Yes, use the GV2V01. When this is padlocked, the starter is automatically in and will remain in the OFF position.