TeSys GV2 Circuit Breaker Thermal Magnetic, 9...14 A, Screw Clamp Terminals

TeSys GV2 Circuit Breaker Thermal Magnetic, 9...14 A, Screw Clamp Terminals

TeSys GV2 Circuit Breaker Thermal Magnetic, 9...14 A, Screw Clamp Terminals

Item Number: GV2ME16

Retail
$551.43
RRP (Inc. GST)

Product Dimensions

Width icon

Width45 mm

Height icon

Height89 mm

Depth icon

Depth78.5 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys GV2

Range

TeSys

Product or component type

circuit breaker

Device application

motor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Fixing mode

  • 35 mm symmetrical DIN rail: clipped
  • panel: screwed (with adaptor plate)
    • Control type

      push-button

      [In] rated current

      14 A

      [Ue] rated operational voltage

      690 V AC 50/60 Hz conforming to IEC 60947-2

      Mechanical durability

      100000 cycles

      Electrical durability

      100000 cycles for AC-3 at 440 V

      Connections - terminals

    • screw clamp terminals 2 cable(s) 1-6 mm² solid
    • screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable end
    • screw clamp terminals 2 cable(s) 1-4 mm² flexible with cable end
      • Height

        89 mm

        Width

        45 mm

        Depth

        78.5 mm

        Net weight

        0.26 kg

        Standards

      • EN/IEC 60947-2
      • EN/IEC 60947-4-1
      • CSA C22.2 No 60947-4-1
      • UL 60947-4-1
        • Product certifications

        • IECEE CB Scheme
        • UL
        • CSA
        • CCC
        • EAC
        • ATEX
        • BV
        • LROS (Lloyds register of shipping)
        • DNV-GL
        • RINA
          • IP degree of protection

            IP20 conforming to IEC 60529

            IK degree of protection

            IK04

            Ambient air temperature for operation

            -20-60 °C

            Ambient air temperature for storage

            -40-80 °C

            EU RoHS Directive

            Compliant

            Mercury free

            Yes

            RoHS exemption information

            Yes

            China RoHS Regulation

            Product out of China RoHS scope. Substance declaration for your information

            Environmental Disclosure

            ENVPEP121004EN

            California proposition 65

            WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov

            Others

            Product name

            TeSys GV2

            Device short name

            GV2ME

            Trip unit technology

            thermal-magnetic

            Poles description

            3P

            Network type

            AC

            Utilisation category

          • AC-3 conforming to IEC 60947-4-1
          • category A conforming to IEC 60947-2
            • Network frequency

              50/60 Hz conforming to IEC 60947-4-1

              Operating position

              any position

              Motor power kW

            • 5.5-5.5 kW at 400/415 V AC 50/60 Hz
            • 7.5-7.5 kW at 500 V AC 50/60 Hz
            • 9-9 kW at 690 V AC 50/60 Hz
            • 11-11 kW at 690 V AC 50/60 Hz
              • Breaking capacity

              • 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
              • 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
              • 15 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
              • 8 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
              • 6 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
                • [Ics] rated service short-circuit breaking capacity

                • 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
                • 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
                • 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
                • 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
                • 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
                  • Trip unit rating

                    9-14 A

                    Magnetic tripping current

                    170-170 A

                    [Ui] rated insulation voltage

                    690 V AC 50/60 Hz conforming to IEC 60947-2

                    [Ith] conventional free air thermal current

                    14 A conforming to IEC 60947-4-1

                    [Uimp] rated impulse withstand voltage

                    Power dissipation per pole

                    2.5 W

                    Maximum operating rate

                    25 cyc/h

                    Rated duty

                    continuous conforming to IEC 60947-4-1

                    Direct connector

                    without

                    Tightening torque

                    1.7 N.m on screw clamp terminals

                    Suitability for isolation

                    yes conforming to IEC 60947-1

                    Phase failure sensitivity

                    yes conforming to IEC 60947-4-1

                    Compatibility code

                    GV2ME

                    Protective treatment

                    TH

                    Fire resistance

                    960 °C conforming to IEC 60695-2-1

                    Operating altitude

                    2000 m

                    Unit Type of Package 1

                    PCE

                    Number of Units in Package 1

                    1

                    Package 1 Weight

                    277 g

                    Package 1 Height

                    4.7 cm

                    Package 1 width

                    8.5 cm

                    Package 1 Length

                    9 cm

                    Unit Type of Package 2

                    S02

                    Number of Units in Package 2

                    24

                    Package 2 Weight

                    7.223 kg

                    Package 2 Height

                    15 cm

                    Package 2 width

                    30 cm

                    Package 2 Length

                    40 cm

                    Unit Type of Package 3

                    P06

                    Number of Units in Package 3

                    384

                    Package 3 Weight

                    122.148 kg

                    Package 3 Height

                    80 cm

                    Package 3 width

                    80 cm

                    Package 3 Length

                    60 cm

                    WEEE

                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                    Show all specifications

                    Documents & downloads

                    hide show
                    Filter items
                    • All

                    • CAD Files and Packs

                    • Product Brochures

                    • Technical Data Catalogues

                    • Installation Instruction

                    • Product Environmental

                    • Data Bulletin

                    • Certificates (MSDS)

                    • Declaration of Conformity

                    • eTechPub

                    Frequently Asked Questions

                    hide show

                    Are explosion proof enclosures available for GV manual motor starters.

                    Issue:
                    NEMA 7/9 rated enclosure for GV manual motor starters

                    Product Line:
                    Tesys GV Motor Starters and Protectors

                    Environment:
                    TeSys™ GV Manual Starters and Protectors

                    Resolution:
                    No hazardous duty enclosures are available for the GV product line.
                    For explosion proof applications consider the Class 2510 Type M or Type T offering.

                    Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

                    Issue:
                    Mounting adaptor for GV2 and LC1D contactor

                    Product Line:
                    Motor Starters and Protectors

                    Environment:
                    TeSys GV Manual Starter and Protectors
                    Tesys D Contactors
                     
                    Resolution:
                    The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

                    Can the GV* starters be used on 50 hertz applications?

                    Issue:
                    GV* Starter for 50/60hz application

                    Product Line:
                    Motor Starters and Protectors

                    Environment:
                    PowerPact™ Manual Starters

                    Resolution:
                    Yes, these starters are rated for 50/60 hertz.

                    This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

                    What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

                    Issue:
                    Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

                    Product Line:
                    Contactors and Starters IEC

                    Environment:
                    Tesys D contactors and GV manual starters

                    Cause:
                    Spacer required

                    Resolution:
                    Compensation plate catalog number GV1F03, requires 2 pieces snap together.

                    Is a padlocking device available for the GV2MC** type enclosures?

                    Issue:
                    Padlocking device for GV2MC Enclosures

                    Product Line:
                    TeSys GV2 Manual Starters and Protectors

                    Environment:
                    n/a

                    Resolution:
                    Yes, use the GV2V01. When this is padlocked, the starter is automatically in and will remain in the OFF position.

                    Will the accessories used for the GV3ME06 through GV3ME63 work with the GV3ME80?

                    Product Line:
                    GV3 manual motor starters, IEC

                    Resolution:
                    The standard GV3 accessories will work on this device.

                    What is the replacement for a GV2M06

                    Use a GV2ME06.

                    Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

                    Issue:
                    Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
                     
                    Product Line:

                    Tesys GV Manual Starter and Protectors

                    Environment:
                    TeSys GV, GVA, GV2, GV3P

                    Resolution:
                    These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.

                    Protection Rating for GV2E01

                    Issue:
                    What rating does the GV2E01 give when used with the GV2MC01 or GV2MP01 enclosure

                    Product Line:
                    GV2 Enclosure Accessories

                    Environment:
                    US Product

                    Cause:
                    The IP rating is not specified in the Digest 176

                    Resolution:
                    When used with the GV2MC01 or GV2MP01, this kit will give a IP55 rating.

                    What would be the part number for an enclosure for the GV2ME20

                    Is there a Nema 1 enclosure for GV2ME14?

                    Issue:
                    What is the Nema 1 enclosure for GV2ME14?

                    Product Line:
                    Motor CBS & Overl. Relay

                    Environment:
                    CTR Optimum - IEC

                    Cause:
                    Enclosure

                    Resolution:
                    GV2MC01, Manual Starter Enclosure Type 1  IP41   answer

                    Does the GVAE11 auxilliary contact block fit the GV2ME?

                    The GVAE11 auxilliary contact block fits in the top of the GV2ME and GV2P/L