TeSys GV2 Circuit Breaker Thermal Magnetic, 0.16...0.25 A, Screw Clamp Terminals

TeSys GV2 Circuit Breaker Thermal Magnetic, 0.16...0.25 A, Screw Clamp Terminals

TeSys GV2 Circuit Breaker Thermal Magnetic, 0.16...0.25 A, Screw Clamp Terminals

Item Number: GV2ME02

Retail
$439.86
RRP (Inc. GST)

Product Dimensions

Width icon

Width45 mm

Height icon

Height89 mm

Depth icon

Depth78.5 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys GV2

Range

TeSys

Product or component type

circuit breaker

Device application

motor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Fixing mode

  • 35 mm symmetrical DIN rail: clipped
  • panel: screwed (with adaptor plate)
    • Control type

      push-button

      [In] rated current

      0.25 A

      [Ue] rated operational voltage

      690 V AC 50/60 Hz conforming to IEC 60947-2

      Mechanical durability

      100000 cycles

      Electrical durability

      100000 cycles for AC-3 at 440 V

      Connections - terminals

    • screw clamp terminals 2 cable(s) 1-6 mm² solid
    • screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable end
    • screw clamp terminals 2 cable(s) 1-4 mm² flexible with cable end
      • Height

        89 mm

        Width

        45 mm

        Depth

        78.5 mm

        Net weight

        0.26 kg

        Standards

      • EN/IEC 60947-2
      • EN/IEC 60947-4-1
      • CSA C22.2 No 60947-4-1
      • UL 60947-4-1
        • Product certifications

        • IECEE CB Scheme
        • UL
        • CSA
        • CCC
        • EAC
        • ATEX
        • BV
        • LROS (Lloyds register of shipping)
        • DNV-GL
        • RINA
          • IP degree of protection

            IP20 conforming to IEC 60529

            IK degree of protection

            IK04

            Ambient air temperature for operation

            -20-60 °C

            Ambient air temperature for storage

            -40-80 °C

            EU RoHS Directive

            Compliant

            Mercury free

            Yes

            RoHS exemption information

            Yes

            China RoHS Regulation

            Product out of China RoHS scope. Substance declaration for your information

            Environmental Disclosure

            ENVPEP121004EN

            Others

            Product name

            TeSys GV2

            Device short name

            GV2ME

            Trip unit technology

            thermal-magnetic

            Poles description

            3P

            Network type

            AC

            Utilisation category

          • AC-3 conforming to IEC 60947-4-1
          • category A conforming to IEC 60947-2
            • Network frequency

              50/60 Hz conforming to IEC 60947-4-1

              Operating position

              any position

              Motor power kW

              0.06-0.06 kW at 400/415 V AC 50/60 Hz

              Breaking capacity

            • 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
              • [Ics] rated service short-circuit breaking capacity

              • 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
              • 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
              • 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
              • 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
              • 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
                • Trip unit rating

                  0.16-0.25 A

                  Magnetic tripping current

                  2.4-2.4 A

                  [Ui] rated insulation voltage

                  690 V AC 50/60 Hz conforming to IEC 60947-2

                  [Ith] conventional free air thermal current

                  0.25 A conforming to IEC 60947-4-1

                  [Uimp] rated impulse withstand voltage

                  Power dissipation per pole

                  2.5 W

                  Maximum operating rate

                  25 cyc/h

                  Rated duty

                  continuous conforming to IEC 60947-4-1

                  Direct connector

                  without

                  Tightening torque

                  1.7 N.m on screw clamp terminals

                  Suitability for isolation

                  yes conforming to IEC 60947-1

                  Phase failure sensitivity

                  yes conforming to IEC 60947-4-1

                  Compatibility code

                  GV2ME

                  Protective treatment

                  TH

                  Fire resistance

                  960 °C conforming to IEC 60695-2-1

                  Operating altitude

                  2000 m

                  Unit Type of Package 1

                  PCE

                  Number of Units in Package 1

                  1

                  Package 1 Weight

                  231 g

                  Package 1 Height

                  4.8 cm

                  Package 1 width

                  8.5 cm

                  Package 1 Length

                  9.3 cm

                  Unit Type of Package 2

                  S02

                  Number of Units in Package 2

                  24

                  Package 2 Weight

                  5.872 kg

                  Package 2 Height

                  15 cm

                  Package 2 width

                  30 cm

                  Package 2 Length

                  40 cm

                  Unit Type of Package 3

                  P06

                  Number of Units in Package 3

                  384

                  Package 3 Weight

                  109.691 kg

                  Package 3 Height

                  80 cm

                  Package 3 width

                  80 cm

                  Package 3 Length

                  60 cm

                  WEEE

                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                  Show all specifications

                  Documents & downloads

                  hide show
                  Filter items
                  • All

                  • CAD Files and Packs

                  • Product Brochures

                  • Technical Data Catalogues

                  • Installation Instruction

                  • Product Environmental

                  • Data Bulletin

                  • Certificates (MSDS)

                  • Declaration of Conformity

                  • eTechPub

                  Frequently Asked Questions

                  hide show

                  Will the Tesys GV2ME starters install into old style enclosures designed for the GV2M, GV2MC01 and GV2MC02 enclosures?

                  Issue:
                  GV2ME compatibility with old enclosure 

                  Product Line:

                  Motor Starters and Protectors

                  Environment:
                  TeSys™ GV Manual Starters and Protectors
                   
                  Resolution:
                  No, Order new enclosures using the same catalog numbers. The current enclosure has an updated DIN attachement which will accept the Tesys GV2ME starters but will not accept the old GV2M starters.

                  Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

                  Issue:
                  Mounting adaptor for GV2 and LC1D contactor

                  Product Line:
                  Motor Starters and Protectors

                  Environment:
                  TeSys GV Manual Starter and Protectors
                  Tesys D Contactors
                   
                  Resolution:
                  The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

                  Are explosion proof enclosures available for GV manual motor starters.

                  Issue:
                  NEMA 7/9 rated enclosure for GV manual motor starters

                  Product Line:
                  Tesys GV Motor Starters and Protectors

                  Environment:
                  TeSys™ GV Manual Starters and Protectors

                  Resolution:
                  No hazardous duty enclosures are available for the GV product line.
                  For explosion proof applications consider the Class 2510 Type M or Type T offering.

                  Can the GV* starters be used on 50 hertz applications?

                  Issue:
                  GV* Starter for 50/60hz application

                  Product Line:
                  Motor Starters and Protectors

                  Environment:
                  PowerPact™ Manual Starters

                  Resolution:
                  Yes, these starters are rated for 50/60 hertz.

                  This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

                  Is a padlocking device available for the GV2MC** type enclosures?

                  Issue:
                  Padlocking device for GV2MC Enclosures

                  Product Line:
                  TeSys GV2 Manual Starters and Protectors

                  Environment:
                  n/a

                  Resolution:
                  Yes, use the GV2V01. When this is padlocked, the starter is automatically in and will remain in the OFF position.

                  What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

                  Issue:
                  Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

                  Product Line:
                  Contactors and Starters IEC

                  Environment:
                  Tesys D contactors and GV manual starters

                  Cause:
                  Spacer required

                  Resolution:
                  Compensation plate catalog number GV1F03, requires 2 pieces snap together.
                  Show More