Gv2 Motor CB Magnetic 32A Toggle Switch

Gv2 Motor CB Magnetic 32A Toggle Switch

Gv2 Motor CB Magnetic 32A Toggle Switch

Item Number: GV2LE32

Retail
$697.13
RRP (Inc. GST)

Product Dimensions

Width icon

Width45 mm

Height icon

Height89 mm

Depth icon

Depth78.5 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys GV2

Range

TeSys

Product or component type

circuit breaker

Device application

motor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Fixing mode

  • 35 mm symmetrical DIN rail: clipped
  • panel: screwed (with adaptor plate)
    • Control type

      toggle

      [In] rated current

      32 A

      [Ue] rated operational voltage

      690 V AC 50/60 Hz conforming to IEC 60947-2

      Mechanical durability

      100000 cycles

      Electrical durability

      100000 cycles for AC-3 at 415 V

      Connections - terminals

    • screw clamp terminals 2 cable(s) 1-6 mm² solid
    • screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable end
    • screw clamp terminals 2 cable(s) 1-4 mm² flexible with cable end
      • Height

        89 mm

        Width

        45 mm

        Depth

        78.5 mm

        Net weight

        0.33 kg

        Standards

      • EN/IEC 60947-2
      • EN/IEC 60947-4-1
        • Product certifications

        • IECEE CB Scheme
        • CCC
        • EAC
        • RINA
        • LROS (Lloyds register of shipping)
        • DNV-GL
        • BV
          • IP degree of protection

            IP20 conforming to IEC 60529

            IK degree of protection

            IK04

            Ambient air temperature for operation

            -20-60 °C

            Ambient air temperature for storage

            -40-80 °C

            EU RoHS Directive

            Compliant

            Mercury free

            Yes

            RoHS exemption information

            Yes

            China RoHS Regulation

            Product out of China RoHS scope. Substance declaration for your information

            Environmental Disclosure

            ENVPEP121004EN

            California proposition 65

            WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov

            Others

            Product name

            TeSys GV2

            Device short name

            GV2LE

            Poles description

            3P

            Network type

            AC

            Utilisation category

          • category A conforming to IEC 60947-2
          • AC-3 conforming to IEC 60947-4-1
            • Network frequency

              50/60 Hz conforming to IEC 60947-2

              Breaking capacity

            • 50 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
            • 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
            • 6 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
            • 4 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
            • 10 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
              • [Ics] rated service short-circuit breaking capacity

              • 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
              • 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
              • 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
              • 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
              • 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
                • Trip unit technology

                  magnetic

                  Magnetic tripping current

                  416-416 A

                  Operating position

                  any position

                  Motor power kW

                • 15-15 kW at 400/415 V AC 50/60 Hz
                • 18.5-18.5 kW at 500 V AC 50/60 Hz
                • 22-22 kW at 690 V AC 50/60 Hz
                  • [Ui] rated insulation voltage

                    690 V AC 50/60 Hz conforming to IEC 60947-2

                    [Uimp] rated impulse withstand voltage

                    Power dissipation per pole

                    1.8 W

                    Maximum operating rate

                    40 cyc/h

                    Rated duty

                    continuous conforming to IEC 60947-4-1

                    Direct connector

                    without

                    Tightening torque

                    1.7 N.m on screw clamp terminals

                    Mechanical robustness

                  • shocks: 30 Gn conforming to IEC 60068-2-27
                  • vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6
                    • Suitability for isolation

                      yes conforming to IEC 60947-1

                      Compatibility code

                      GV2LE

                      Protective treatment

                      TH

                      Fire resistance

                      960 °C conforming to IEC 60695-2-1

                      Operating altitude

                      0...2000 m

                      Unit Type of Package 1

                      PCE

                      Number of Units in Package 1

                      1

                      Package 1 Weight

                      278 g

                      Package 1 Height

                      4.8 cm

                      Package 1 width

                      8.5 cm

                      Package 1 Length

                      9.3 cm

                      Unit Type of Package 2

                      S02

                      Number of Units in Package 2

                      24

                      Package 2 Weight

                      6.994 kg

                      Package 2 Height

                      15 cm

                      Package 2 width

                      30 cm

                      Package 2 Length

                      40 cm

                      Unit Type of Package 3

                      P06

                      Number of Units in Package 3

                      384

                      Package 3 Weight

                      125.604 kg

                      Package 3 Height

                      80 cm

                      Package 3 width

                      80 cm

                      Package 3 Length

                      60 cm

                      WEEE

                      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                      Show all specifications

                      Documents & downloads

                      hide show
                      Filter items
                      • All

                      • CAD Files and Packs

                      • Product Brochures

                      • Technical Data Catalogues

                      • Product Environmental

                      • Installation Instruction

                      • Data Bulletin

                      • eTechPub

                      Frequently Asked Questions

                      hide show

                      Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

                      Issue:
                      Mounting adaptor for GV2 and LC1D contactor

                      Product Line:
                      Motor Starters and Protectors

                      Environment:
                      TeSys GV Manual Starter and Protectors
                      Tesys D Contactors
                       
                      Resolution:
                      The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

                      Are explosion proof enclosures available for GV manual motor starters.

                      Issue:
                      NEMA 7/9 rated enclosure for GV manual motor starters

                      Product Line:
                      Tesys GV Motor Starters and Protectors

                      Environment:
                      TeSys™ GV Manual Starters and Protectors

                      Resolution:
                      No hazardous duty enclosures are available for the GV product line.
                      For explosion proof applications consider the Class 2510 Type M or Type T offering.

                      What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

                      Issue:
                      Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

                      Product Line:
                      Contactors and Starters IEC

                      Environment:
                      Tesys D contactors and GV manual starters

                      Cause:
                      Spacer required

                      Resolution:
                      Compensation plate catalog number GV1F03, requires 2 pieces snap together.

                      Is a padlocking device available for the GV2MC** type enclosures?

                      Issue:
                      Padlocking device for GV2MC Enclosures

                      Product Line:
                      TeSys GV2 Manual Starters and Protectors

                      Environment:
                      n/a

                      Resolution:
                      Yes, use the GV2V01. When this is padlocked, the starter is automatically in and will remain in the OFF position.

                      Can the GV* starters be used on 50 hertz applications?

                      Issue:
                      GV* Starter for 50/60hz application

                      Product Line:
                      Motor Starters and Protectors

                      Environment:
                      PowerPact™ Manual Starters

                      Resolution:
                      Yes, these starters are rated for 50/60 hertz.

                      This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

                      GV2P disconnect options

                      Issue:
                      What is the product number for a complete through-the-door disconnect device for a GV2P

                      Product Line:
                      GV2P Manual Starters and Protectors

                      Environment:
                      US product

                      Cause:
                      Digest 176 is unclear as to what is a complete mechanism with shaft and handle

                      Resolution:
                      There are three devices which include mechanism, shaft and handle:
                      GV2APN01 has a NEMA 1, 12 rating and is black
                      GV2APN02 has a NEMA 1, 12 rating and is red/yellow
                      GV2APN04 has a NEMA 3R, 4, 4X rating and is red/yellow

                      Can I get the front membrane for a GV2MC03

                       The part code is a GV2E02

                      Will the accessories used for the GV3ME06 through GV3ME63 work with the GV3ME80?

                      Product Line:
                      GV3 manual motor starters, IEC

                      Resolution:
                      The standard GV3 accessories will work on this device.

                      What options can I use if the LS1D32 is not available

                      You can use GV2P32 & GV3P32

                      What would be the part number for an enclosure for the GV2ME20

                      Can I use a GV2 on a Altivar drive output?

                      Issue: 
                      Can I use a GV2 on a Altivar drive output?    

                      Product Line:
                      Alitvar Drives

                      Environment: 
                      ATV61, ATV212, ATV71, ATV630, ATV930, ATV32, ATV320, ATV312, ATV12, ATV660, ATV340  

                      Cause
                      Application has 2 motors on one drive wants separate disconnects.

                      Resolution: 
                      Not recommended on Altivar drives.
                      The GV2 have a fixed frequency range 50 to 60hz.
                      Possible intermittent trips used with the drive's PWM output.
                       

                      What is the equivalent of GV2AP01 and GV2AP02 rotary handle

                      The equivalent of GV2AP01 and GV2AP02 rotary handles are GV2APN01          
                       and GV2APN02 respectively.Refer attached file for more details