MANUAL SWITCH 600VAC 10AMP IEC
TeSys motor circuit breaker GV2-LE
Magnetic circuit-breaker TeSys GV2LE, control by rocker lever, with screw clamp terminals, 0.4A to 32A
MANUAL SWITCH 600VAC 10AMP IEC
TeSys motor circuit breaker GV2-LE
Magnetic circuit-breaker TeSys GV2LE, control by rocker lever, with screw clamp terminals, 0.4A to 32A

Gv2 Motor CB Magnetic 10A Toggle Switch

Catalogue Number: GV2LE14
MANUAL SWITCH 600VAC 10AMP IEC
TeSys motor circuit breaker GV2-LE
Magnetic circuit-breaker TeSys GV2LE, control by rocker lever, with screw clamp terminals, 0.4A to 32A
MANUAL SWITCH 600VAC 10AMP IEC
TeSys motor circuit breaker GV2-LE
Magnetic circuit-breaker TeSys GV2LE, control by rocker lever, with screw clamp terminals, 0.4A to 32A
Retail
$437.14
RRP (Inc. GST)

Specifications

hide show
Range of product
TeSys GV2
Range
TeSys
Product name
TeSys GV2
Device short name
GV2LE
Product or component type
circuit breaker
Device application
motor
Poles description
3P
Network type
AC
Utilisation category
  • category A conforming to IEC 60947-2
  • AC-3 conforming to IEC 60947-4-1
    • Network frequency
      50/60 Hz conforming to IEC 60947-2
      Breaking capacity
    • 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
    • 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
    • 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
    • 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
    • 15 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
      • [Ics] rated service short-circuit breaking capacity
      • 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
      • 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
      • 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
      • 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
      • 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
        • Trip unit technology
          magnetic
          Magnetic tripping current
          138-138 A
          Fixing mode
        • 35 mm symmetrical DIN rail: clipped
        • panel: screwed (with adaptor plate)
          • Operating position
            any position
            Motor power kW
          • 3-3 kW at 400/415 V AC 50/60 Hz
          • 4-4 kW at 400/415 V AC 50/60 Hz
          • 4-4 kW at 500 V AC 50/60 Hz
          • 5.5-5.5 kW at 690 V AC 50/60 Hz
          • 7.5-7.5 kW at 690 V AC 50/60 Hz
          • 5.5-5.5 kW at 500 V AC 50/60 Hz
            • Control type
              toggle
              [In] rated current
              10 A
              [Ue] rated operational voltage
              690 V AC 50/60 Hz conforming to IEC 60947-2
              [Ui] rated insulation voltage
              690 V AC 50/60 Hz conforming to IEC 60947-2
              [Uimp] rated impulse withstand voltage
              Power dissipation per pole
              1.8 W
              Mechanical durability
              100000 cycles
              Electrical durability
              100000 cycles for AC-3 at 415 V
              Maximum operating rate
              40 cyc/h
              Rated duty
              continuous conforming to IEC 60947-4-1
              Direct connector
              without
              Connections - terminals
            • screw clamp terminals 2 cable(s) 1-6 mm² solid
            • screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable end
            • screw clamp terminals 2 cable(s) 1-4 mm² flexible with cable end
              • Tightening torque
                1.7 N.m on screw clamp terminals
                Mechanical robustness
              • shocks: 30 Gn conforming to IEC 60068-2-27
              • vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6
                • Suitability for isolation
                  yes conforming to IEC 60947-1
                  Height
                  89 mm
                  Width
                  45 mm
                  Depth
                  78.5 mm
                  Net weight
                  0.33 kg
                  Compatibility code
                  GV2LE
                  Standards
                • EN/IEC 60947-2
                • EN/IEC 60947-4-1
                • CSA C22.2 No 60947-4-1
                • UL 60947-4-1
                  • Product certifications
                  • IECEE CB Scheme
                  • UL
                  • CSA
                  • CCC
                  • EAC
                  • RINA
                  • LROS (Lloyds register of shipping)
                  • DNV-GL
                  • BV
                    • Protective treatment
                      TH
                      IP degree of protection
                      IP20 conforming to IEC 60529
                      IK degree of protection
                      IK04
                      Ambient air temperature for operation
                      -20-60 °C
                      Ambient air temperature for storage
                      -40-80 °C
                      Fire resistance
                      960 °C conforming to IEC 60695-2-1
                      Operating altitude
                      0...2000 m
                      Unit Type of Package 1
                      PCE
                      Number of Units in Package 1
                      1
                      Package 1 Weight
                      270 g
                      Package 1 Height
                      4.8 cm
                      Package 1 width
                      8.5 cm
                      Package 1 Length
                      9.3 cm
                      Unit Type of Package 2
                      S02
                      Number of Units in Package 2
                      24
                      Package 2 Weight
                      6.83 kg
                      Package 2 Height
                      15 cm
                      Package 2 width
                      30 cm
                      Package 2 Length
                      40 cm
                      Unit Type of Package 3
                      P06
                      Number of Units in Package 3
                      384
                      Package 3 Weight
                      119.46 kg
                      Package 3 Height
                      80 cm
                      Package 3 width
                      80 cm
                      Package 3 Length
                      60 cm
                      Sustainable offer status
                      Green Premium product
                      EU RoHS Directive
                      Compliant
                      Mercury free
                      Yes
                      RoHS exemption information
                      Yes
                      China RoHS Regulation
                      Product out of China RoHS scope. Substance declaration for your information
                      Environmental Disclosure
                      ENVPEP121004EN
                      WEEE
                      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                      California proposition 65
                      WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
                      Warranty
                      18 months

                      Documents & downloads

                      hide show
                      Filter items
                      • All

                      • CAD Files and Packs

                      • Product Brochures

                      • Technical Data Catalogues

                      • Product Environmental

                      • Installation Instruction

                      • Data Bulletin

                      • eTechPub

                      Frequently Asked Questions

                      hide show

                      Are explosion proof enclosures available for GV manual motor starters.

                      Issue:
                      NEMA 7/9 rated enclosure for GV manual motor starters

                      Product Line:
                      Tesys GV Motor Starters and Protectors

                      Environment:
                      TeSys™ GV Manual Starters and Protectors

                      Resolution:
                      No hazardous duty enclosures are available for the GV product line.
                      For explosion proof applications consider the Class 2510 Type M or Type T offering.

                      Can the GV* starters be used on 50 hertz applications?

                      Issue:
                      GV* Starter for 50/60hz application

                      Product Line:
                      Motor Starters and Protectors

                      Environment:
                      PowerPact™ Manual Starters

                      Resolution:
                      Yes, these starters are rated for 50/60 hertz.

                      This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

                      Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

                      Issue:
                      Mounting adaptor for GV2 and LC1D contactor

                      Product Line:
                      Motor Starters and Protectors

                      Environment:
                      TeSys GV Manual Starter and Protectors
                      Tesys D Contactors
                       
                      Resolution:
                      The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

                      What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

                      Issue:
                      Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

                      Product Line:
                      Contactors and Starters IEC

                      Environment:
                      Tesys D contactors and GV manual starters

                      Cause:
                      Spacer required

                      Resolution:
                      Compensation plate catalog number GV1F03, requires 2 pieces snap together.

                      Is a padlocking device available for the GV2MC** type enclosures?

                      Issue:
                      Padlocking device for GV2MC Enclosures

                      Product Line:
                      TeSys GV2 Manual Starters and Protectors

                      Environment:
                      n/a

                      Resolution:
                      Yes, use the GV2V01. When this is padlocked, the starter is automatically in and will remain in the OFF position.

                      Protection Rating for GV2E01

                      Issue:
                      What rating does the GV2E01 give when used with the GV2MC01 or GV2MP01 enclosure

                      Product Line:
                      GV2 Enclosure Accessories

                      Environment:
                      US Product

                      Cause:
                      The IP rating is not specified in the Digest 176

                      Resolution:
                      When used with the GV2MC01 or GV2MP01, this kit will give a IP55 rating.

                      Is there a Nema 1 enclosure for GV2ME14?

                      Issue:
                      What is the Nema 1 enclosure for GV2ME14?

                      Product Line:
                      Motor CBS & Overl. Relay

                      Environment:
                      CTR Optimum - IEC

                      Cause:
                      Enclosure

                      Resolution:
                      GV2MC01, Manual Starter Enclosure Type 1  IP41   answer

                      GV2P disconnect options

                      Issue:
                      What is the product number for a complete through-the-door disconnect device for a GV2P

                      Product Line:
                      GV2P Manual Starters and Protectors

                      Environment:
                      US product

                      Cause:
                      Digest 176 is unclear as to what is a complete mechanism with shaft and handle

                      Resolution:
                      There are three devices which include mechanism, shaft and handle:
                      GV2APN01 has a NEMA 1, 12 rating and is black
                      GV2APN02 has a NEMA 1, 12 rating and is red/yellow
                      GV2APN04 has a NEMA 3R, 4, 4X rating and is red/yellow

                      What does Pitch refer to in regards to the GV2G busbar system?

                      Issue: 
                      Need to know what 45mm, 54mm, and 72mm pitch means

                      Product Line:
                      GV2 Manual Starters

                      Environment:
                      n/a

                      Resolution:
                      The pitch is the spacing between slots.  In order to select the correct pitch, total up the width of the device, plus any side mounted auxiliaries.  Use the total width for selecting the proper pitch. The busbar pitch selection must be the same or greater than the sum of device and auxiliaries.

                      Will the accessories used for the GV3ME06 through GV3ME63 work with the GV3ME80?

                      Product Line:
                      GV3 manual motor starters, IEC

                      Resolution:
                      The standard GV3 accessories will work on this device.

                      Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

                      Issue:
                      Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
                       
                      Product Line:

                      Tesys GV Manual Starter and Protectors

                      Environment:
                      TeSys GV, GVA, GV2, GV3P

                      Resolution:
                      These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.

                      What would be the part number for an enclosure for the GV2ME20

                      Show More