Gv2 Motor CB Magnetic 6.3A Toggle Switch

Gv2 Motor CB Magnetic 6.3A Toggle Switch

Gv2 Motor CB Magnetic 6.3A Toggle Switch

Item Number: GV2LE10

Retail
$369.00
RRP (Inc. GST)

Product Dimensions

Width icon

Width45 mm

Height icon

Height89 mm

Depth icon

Depth78.5 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys GV2

Range

TeSys

Product or component type

circuit breaker

Device application

motor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Fixing mode

  • 35 mm symmetrical DIN rail: clipped
  • panel: screwed (with adaptor plate)
    • Control type

      toggle

      [In] rated current

      6.3 A

      [Ue] rated operational voltage

      690 V AC 50/60 Hz conforming to IEC 60947-2

      Mechanical durability

      100000 cycles

      Electrical durability

      100000 cycles for AC-3 at 415 V

      Connections - terminals

    • screw clamp terminals 2 cable(s) 1-6 mm² solid
    • screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable end
    • screw clamp terminals 2 cable(s) 1-4 mm² flexible with cable end
      • Height

        89 mm

        Width

        45 mm

        Depth

        78.5 mm

        Net weight

        0.33 kg

        Standards

      • EN/IEC 60947-2
      • EN/IEC 60947-4-1
      • CSA C22.2 No 60947-4-1
      • UL 60947-4-1
        • Product certifications

        • IECEE CB Scheme
        • UL
        • CSA
        • CCC
        • EAC
        • RINA
        • LROS (Lloyds register of shipping)
        • DNV-GL
        • BV
          • IP degree of protection

            IP20 conforming to IEC 60529

            IK degree of protection

            IK04

            Ambient air temperature for operation

            -20-60 °C

            Ambient air temperature for storage

            -40-80 °C

            EU RoHS Directive

            Compliant

            Mercury free

            Yes

            RoHS exemption information

            Yes

            China RoHS Regulation

            Product out of China RoHS scope. Substance declaration for your information

            Environmental Disclosure

            ENVPEP121004EN

            California proposition 65

            WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov

            Others

            Product name

            TeSys GV2

            Device short name

            GV2LE

            Poles description

            3P

            Network type

            AC

            Utilisation category

          • category A conforming to IEC 60947-2
          • AC-3 conforming to IEC 60947-4-1
            • Network frequency

              50/60 Hz conforming to IEC 60947-2

              Breaking capacity

            • 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
            • 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
            • 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
            • 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
              • [Ics] rated service short-circuit breaking capacity

              • 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
              • 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
              • 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
              • 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
              • 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
                • Trip unit technology

                  magnetic

                  Magnetic tripping current

                  78-78 A

                  Operating position

                  any position

                  Motor power kW

                • 2.2-2.2 kW at 400/415 V AC 50/60 Hz
                • 3-3 kW at 500 V AC 50/60 Hz
                • 4-4 kW at 690 V AC 50/60 Hz
                  • [Ui] rated insulation voltage

                    690 V AC 50/60 Hz conforming to IEC 60947-2

                    [Uimp] rated impulse withstand voltage

                    Power dissipation per pole

                    1.8 W

                    Maximum operating rate

                    40 cyc/h

                    Rated duty

                    continuous conforming to IEC 60947-4-1

                    Direct connector

                    without

                    Tightening torque

                    1.7 N.m on screw clamp terminals

                    Mechanical robustness

                  • shocks: 30 Gn conforming to IEC 60068-2-27
                  • vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6
                    • Suitability for isolation

                      yes conforming to IEC 60947-1

                      Compatibility code

                      GV2LE

                      Protective treatment

                      TH

                      Fire resistance

                      960 °C conforming to IEC 60695-2-1

                      Operating altitude

                      0...2000 m

                      Unit Type of Package 1

                      PCE

                      Number of Units in Package 1

                      1

                      Package 1 Weight

                      271 g

                      Package 1 Height

                      4.8 cm

                      Package 1 width

                      8.5 cm

                      Package 1 Length

                      9.3 cm

                      Unit Type of Package 2

                      S02

                      Number of Units in Package 2

                      24

                      Package 2 Weight

                      6.772 kg

                      Package 2 Height

                      15 cm

                      Package 2 width

                      30 cm

                      Package 2 Length

                      40 cm

                      Unit Type of Package 3

                      P06

                      Number of Units in Package 3

                      384

                      Package 3 Weight

                      119.844 kg

                      Package 3 Height

                      80 cm

                      Package 3 width

                      80 cm

                      Package 3 Length

                      60 cm

                      WEEE

                      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                      Show all specifications

                      Documents & downloads

                      hide show
                      Filter items
                      • All

                      • CAD Files and Packs

                      • Product Brochures

                      • Technical Data Catalogues

                      • Product Environmental

                      • Installation Instruction

                      • eTechPub

                      Frequently Asked Questions

                      hide show

                      Are explosion proof enclosures available for GV manual motor starters.

                      Issue:
                      NEMA 7/9 rated enclosure for GV manual motor starters

                      Product Line:
                      Tesys GV Motor Starters and Protectors

                      Environment:
                      TeSys™ GV Manual Starters and Protectors

                      Resolution:
                      No hazardous duty enclosures are available for the GV product line.
                      For explosion proof applications consider the Class 2510 Type M or Type T offering.

                      Can the GV* starters be used on 50 hertz applications?

                      Issue:
                      GV* Starter for 50/60hz application

                      Product Line:
                      Motor Starters and Protectors

                      Environment:
                      PowerPact™ Manual Starters

                      Resolution:
                      Yes, these starters are rated for 50/60 hertz.

                      This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

                      Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

                      Issue:
                      Mounting adaptor for GV2 and LC1D contactor

                      Product Line:
                      Motor Starters and Protectors

                      Environment:
                      TeSys GV Manual Starter and Protectors
                      Tesys D Contactors
                       
                      Resolution:
                      The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

                      What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

                      Issue:
                      Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

                      Product Line:
                      Contactors and Starters IEC

                      Environment:
                      Tesys D contactors and GV manual starters

                      Cause:
                      Spacer required

                      Resolution:
                      Compensation plate catalog number GV1F03, requires 2 pieces snap together.

                      Is a padlocking device available for the GV2MC** type enclosures?

                      Issue:
                      Padlocking device for GV2MC Enclosures

                      Product Line:
                      TeSys GV2 Manual Starters and Protectors

                      Environment:
                      n/a

                      Resolution:
                      Yes, use the GV2V01. When this is padlocked, the starter is automatically in and will remain in the OFF position.

                      Will the accessories used for the GV3ME06 through GV3ME63 work with the GV3ME80?

                      Product Line:
                      GV3 manual motor starters, IEC

                      Resolution:
                      The standard GV3 accessories will work on this device.

                      What would be the part number for an enclosure for the GV2ME20

                      Do we offer a cable operated handle mechanism for the GV7 starters?

                      Issue:
                      They need to mount the GV7 back inside the enclosure and need a handle mechanism with a cable to operate. 

                      Product line:
                      Tesys GV7 manual motor controller

                      Environment:
                      all

                      Cause:
                      n/a

                      Resolution:
                      The GV7 do not offer a cable operator.  Consider switching to a Powerpact circuit breaker which offers the cable mechanism kits.

                      What is the catalog number for an external rotary handle for a GV7 manual starter ?

                      Issue:
                      GV7 Manual starter handle kit

                      Product Line:
                      Motor Starters and Protectors

                      Environment:
                      TeSys™ GV Manual Starters and Protectors

                      Resolution:
                      Use the GV7AP01 for a black handle with black legend or a GV7AP02 for a red handle with yellow legend.

                      Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

                      Issue:
                      Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
                       
                      Product Line:

                      Tesys GV Manual Starter and Protectors

                      Environment:
                      TeSys GV, GVA, GV2, GV3P

                      Resolution:
                      These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.

                      GV2P disconnect options

                      Issue:
                      What is the product number for a complete through-the-door disconnect device for a GV2P

                      Product Line:
                      GV2P Manual Starters and Protectors

                      Environment:
                      US product

                      Cause:
                      Digest 176 is unclear as to what is a complete mechanism with shaft and handle

                      Resolution:
                      There are three devices which include mechanism, shaft and handle:
                      GV2APN01 has a NEMA 1, 12 rating and is black
                      GV2APN02 has a NEMA 1, 12 rating and is red/yellow
                      GV2APN04 has a NEMA 3R, 4, 4X rating and is red/yellow

                      Protection Rating for GV2E01

                      Issue:
                      What rating does the GV2E01 give when used with the GV2MC01 or GV2MP01 enclosure

                      Product Line:
                      GV2 Enclosure Accessories

                      Environment:
                      US Product

                      Cause:
                      The IP rating is not specified in the Digest 176

                      Resolution:
                      When used with the GV2MC01 or GV2MP01, this kit will give a IP55 rating.

                      Show More