Quantcast

Magnetic Circuit Breaker

Product Dimensions

Width icon

Width45 mm

Height icon

Height89 mm

Depth icon

Depth97 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Range of product

TeSys GV2

Product or component type

circuit breaker

Device application

motor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Fixing mode

  • 35 mm symmetrical DIN rail: clipped
  • panel: screwed (with 2 x M4 screws)
    • Control type

      rotary knob

      [In] rated current

      18 A

      [Ue] rated operational voltage

      690 V AC 50/60 Hz conforming to IEC 60947-2

      Mechanical durability

      100000 cycles

      Electrical durability

      100000 cycles for AC-3 at 415 V

      Connections - terminals

    • screw clamp terminals 2 cable(s) 1-6 mm² solid
    • screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable end
    • screw clamp terminals 2 cable(s) 1-4 mm² flexible with cable end
      • Height

        89 mm

        Width

        45 mm

        Depth

        97 mm

        Net weight

        0.33 kg

        Standards

      • EN/IEC 60947-2
      • EN/IEC 60947-4-1
      • CSA C22.2 No 60947-4-1
      • UL 60947-4-1
        • Product certifications

        • IECEE CB Scheme
        • UL
        • CSA
        • CCC
        • EAC
        • RINA
        • LROS (Lloyds register of shipping)
        • DNV-GL
        • BV
          • IP degree of protection

            IP20 conforming to IEC 60529

            IK degree of protection

            IK04

            Ambient air temperature for operation

            -20-60 °C

            Ambient air temperature for storage

            -40-80 °C

            REACh Regulation

            Free of Substances of Very High Concern above the threshold

            EU RoHS Directive

            Compliant

            Mercury free

            Yes

            RoHS exemption information

            Yes

            China RoHS Regulation

            Product out of China RoHS scope. Substance declaration for your information

            Environmental Disclosure

            ENVPEP121004EN

            California proposition 65

            WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

            Others

            Product name

            TeSys GV2

            Device short name

            GV2L

            Poles description

            3P

            Network type

            AC

            Utilisation category

          • category A conforming to IEC 60947-2
          • AC-3 conforming to IEC 60947-4-1
            • Network frequency

              50/60 Hz conforming to IEC 60947-2

              Breaking capacity

            • 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
            • 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
            • 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
            • 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
            • 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
              • [Ics] rated service short-circuit breaking capacity

              • 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
              • 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
              • 75 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
              • 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
              • 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
                • Trip unit technology

                  magnetic

                  Magnetic tripping current

                  223-223 A

                  Operating position

                  any position

                  Motor power kW

                • 7.5-7.5 kW at 400/415 V AC 50/60 Hz
                • 9-9 kW at 500 V AC 50/60 Hz
                • 15-15 kW at 690 V AC 50/60 Hz
                  • [Ui] rated insulation voltage

                    690 V AC 50/60 Hz conforming to IEC 60947-2

                    [Uimp] rated impulse withstand voltage

                    Power dissipation per pole

                    1.8 W

                    Maximum operating rate

                    40 cyc/h

                    Rated duty

                    continuous conforming to IEC 60947-4-1

                    Direct connector

                    without

                    Tightening torque

                    1.7 N.m on screw clamp terminals

                    Mechanical robustness

                  • shocks: 30 Gn conforming to IEC 60068-2-27
                  • vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6
                    • Suitability for isolation

                      yes conforming to IEC 60947-1

                      Compatibility code

                      GV2L

                      Protective treatment

                      TH

                      Fire resistance

                      960 °C conforming to IEC 60695-2-1

                      Operating altitude

                      0...2000 m

                      Unit Type of Package 1

                      PCE

                      Number of Units in Package 1

                      1

                      Package 1 Weight

                      330 g

                      Package 1 Height

                      4.6 cm

                      Package 1 width

                      9.3 cm

                      Package 1 Length

                      10 cm

                      Unit Type of Package 2

                      S02

                      Number of Units in Package 2

                      20

                      Package 2 Weight

                      6.93 kg

                      Package 2 Height

                      15 cm

                      Package 2 width

                      30 cm

                      Package 2 Length

                      40 cm

                      Unit Type of Package 3

                      P06

                      Number of Units in Package 3

                      240

                      Package 3 Weight

                      94.6 kg

                      Package 3 Height

                      80 cm

                      Package 3 width

                      80 cm

                      Package 3 Length

                      60 cm

                      WEEE

                      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                      Show all specifications

                      Documents & downloads

                      hide show
                      Filter items
                      • All

                      • CAD Files and Packs

                      • Product Brochures

                      • Technical Data Catalogues

                      • Installation Instruction

                      • Product Environmental

                      • Data Bulletin

                      • eTechPub

                      Frequently Asked Questions

                      hide show

                      Can the GV* starters be used on 50 hertz applications?

                      Issue:
                      GV* Starter for 50/60hz application

                      Product Line:
                      Motor Starters and Protectors

                      Environment:
                      PowerPact™ Manual Starters

                      Resolution:
                      Yes, these starters are rated for 50/60 hertz.

                      This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

                      What would be the part number for an enclosure for the GV2ME20

                      What is the IP rating of GVAE20? Would the IP rating of GV2P circuit breaker (IP20) get affected by the addition of Aux contact GVAE20?

                      The IP rating of GVAE20 is IP 20.

                      The IP rating of GV2* with GVAE20 is then IP20. It would not get affected by the addition of the Auxiliary 

                      Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

                      Issue:
                      Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
                       
                      Product Line:

                      Tesys GV Manual Starter and Protectors

                      Environment:
                      TeSys GV, GVA, GV2, GV3P

                      Resolution:
                      These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.

                      What items does the GV2PC02 enclosure suit?

                      The GV2PC02 is for GV2P and GV2L, 0.55 to 15kW.

                      What is the operation of the GV2AD fault signalling contacts of the GV2 motor protection circuit breakers?

                      GV2ME, GV2P, GV2L, GV2LE, GV3P and GV3L Motor protection circuit breakers (MPCB) can be fitted with the following optional fault indicating contact blocks:
                       

                      GVAD0110
                      GVAD0101
                      GVAD1010
                      GVAD1001

                      These blocks comprise of fault signalling contacts and instantaneous auxiliary contacts

                      GVAD0110

                      A N/O instantaneous auxiliary contact (terminals 53-54), closed when the device is energized and open when the device is de-energized

                      A N/C fault signalling contact (terminals 95-96), closed if there is no fault, open when a fault (magnetic or thermal) occurs. 

                      GVAD0101

                      A N/C instantaneous auxiliary contact (terminals 51-52), closed when the device is de-energised and open when the device is energised.

                      A N/C fault signalling contact (terminals 95-96), closed if there is no fault, open when a fault (magnetic or thermal) occurs. 

                      GVAD1010 

                      A N/O instantaneous auxiliary contact (terminals 53-54), closed when the device is energized and open when the device is de-energized.

                      A N/O fault signalling contact (terminals 97-98), open if there is no fault, closed when a fault (magnetic or thermal) occurs. 
                       

                      GVAD1001

                      A N/C instantaneous auxiliary contact (terminals 51-52), closed when the device is de-energized and open when the device is energized.

                      A N/O fault signalling contact (terminals 97-98), open if there is no fault, closed when a fault (magnetic or thermal) occurs. 
                       


                      The instantaneous auxiliary contact test is performed by creating a state of transition of the handle actuator between the de-energized position and the energized position.

                      The fault contact test is performed by pressing the test button when the handle actuator is in the closed position.

                      Show More