Specifications

hide show
Range of product
TeSys GV2
Range
TeSys
Product name
TeSys GV2
Device short name
GV2L
Product or component type
circuit breaker
Device application
motor
Poles description
3P
Network type
AC
Utilisation category
  • category A conforming to IEC 60947-2
  • AC-3 conforming to IEC 60947-4-1
    • Network frequency
      50/60 Hz conforming to IEC 60947-2
      Breaking capacity
    • 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
    • 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
    • 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
    • 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
    • 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
      • [Ics] rated service short-circuit breaking capacity
      • 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
      • 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
      • 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
      • 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
      • 75 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
        • Trip unit technology
          magnetic
          Magnetic tripping current
          138-138 A
          Fixing mode
        • 35 mm symmetrical DIN rail: clipped
        • panel: screwed (with 2 x M4 screws)
          • Operating position
            any position
            Motor power kW
          • 3-3 kW at 400/415 V AC 50/60 Hz
          • 4-4 kW at 400/415 V AC 50/60 Hz
          • 4-4 kW at 500 V AC 50/60 Hz
          • 5.5-5.5 kW at 690 V AC 50/60 Hz
          • 7.5-7.5 kW at 690 V AC 50/60 Hz
            • Control type
              rotary knob
              [In] rated current
              10 A
              [Ue] rated operational voltage
              690 V AC 50/60 Hz conforming to IEC 60947-2
              [Ui] rated insulation voltage
              690 V AC 50/60 Hz conforming to IEC 60947-2
              [Uimp] rated impulse withstand voltage
              Power dissipation per pole
              1.8 W
              Mechanical durability
              100000 cycles
              Electrical durability
              100000 cycles for AC-3 at 415 V
              Maximum operating rate
              40 cyc/h
              Rated duty
              continuous conforming to IEC 60947-4-1
              Direct connector
              without
              Connections - terminals
            • screw clamp terminals 2 cable(s) 1-6 mm² solid
            • screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable end
            • screw clamp terminals 2 cable(s) 1-4 mm² flexible with cable end
              • Tightening torque
                1.7 N.m on screw clamp terminals
                Mechanical robustness
              • shocks: 30 Gn conforming to IEC 60068-2-27
              • vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6
                • Suitability for isolation
                  yes conforming to IEC 60947-1
                  Height
                  89 mm
                  Width
                  45 mm
                  Depth
                  97 mm
                  Net weight
                  0.33 kg
                  Compatibility code
                  GV2L
                  Standards
                • EN/IEC 60947-2
                • EN/IEC 60947-4-1
                • CSA C22.2 No 60947-4-1
                • UL 60947-4-1
                  • Product certifications
                  • IECEE CB Scheme
                  • UL
                  • CSA
                  • CCC
                  • EAC
                  • RINA
                  • LROS (Lloyds register of shipping)
                  • DNV-GL
                  • BV
                    • Protective treatment
                      TH
                      IP degree of protection
                      IP20 conforming to IEC 60529
                      IK degree of protection
                      IK04
                      Ambient air temperature for operation
                      -20-60 °C
                      Ambient air temperature for storage
                      -40-80 °C
                      Fire resistance
                      960 °C conforming to IEC 60695-2-1
                      Operating altitude
                      0...2000 m
                      Sustainable offer status
                      Green Premium product
                      REACh Regulation
                      Reference contains Substances of Very High Concern above the threshold
                      EU RoHS Directive
                      Compliant
                      Mercury free
                      Yes
                      RoHS exemption information
                      Yes
                      China RoHS Regulation
                      Product out of China RoHS scope. Substance declaration for your information
                      Environmental Disclosure
                      ENVPEP121004EN
                      Circularity Profile
                      N/A
                      WEEE
                      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                      California proposition 65
                      WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
                      Warranty
                      18 months

                      Documents & downloads

                      hide show
                      Filter items
                      • All

                      • CAD Files and Packs

                      • Product Brochures

                      • Movies

                      • Technical Data Catalogues

                      • Catalog Page

                      • Technical Leaflet

                      • Installation Instruction

                      • Data Bulletin

                      • Product Environmental

                      • Handout

                      • Specification for Tender

                      • eTechPub

                      • Marine Certificate

                      • White Paper

                      • Certificates (MSDS)

                      • Declaration of Conformity

                      • Software - Released

                      Frequently Asked Questions

                      hide show

                      Can the GV* starters be used on 50 hertz applications?

                      Issue:
                      GV* Starter for 50/60hz application

                      Product Line:
                      Motor Starters and Protectors

                      Environment:
                      PowerPact™ Manual Starters

                      Resolution:
                      Yes, these starters are rated for 50/60 hertz.

                      This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

                      GV2P disconnect options

                      Issue:
                      What is the product number for a complete through-the-door disconnect device for a GV2P

                      Product Line:
                      GV2P Manual Starters and Protectors

                      Environment:
                      US product

                      Cause:
                      Digest 176 is unclear as to what is a complete mechanism with shaft and handle

                      Resolution:
                      There are three devices which include mechanism, shaft and handle:
                      GV2APN01 has a NEMA 1, 12 rating and is black
                      GV2APN02 has a NEMA 1, 12 rating and is red/yellow
                      GV2APN04 has a NEMA 3R, 4, 4X rating and is red/yellow

                      What is the part code for the Adaptor to join the GV2P16 to a LC1D09BL

                      You can use GV2AF3 or GV2AF4 + LAD31

                      Protection Rating for GV2E01

                      Issue:
                      What rating does the GV2E01 give when used with the GV2MC01 or GV2MP01 enclosure

                      Product Line:
                      GV2 Enclosure Accessories

                      Environment:
                      US Product

                      Cause:
                      The IP rating is not specified in the Digest 176

                      Resolution:
                      When used with the GV2MC01 or GV2MP01, this kit will give a IP55 rating.

                      What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

                      Issue:
                      Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

                      Product Line:
                      Digest 177 Section 18 : Contactors and Starters IEC

                      Environment:
                      Products sold and used in the United States

                      Cause:
                      Spacer required

                      Resolution:
                      Compensation plate catalog number GV1F03, requires 2 pieces snap together.
                       

                      What is the operation of the GV2AD fault signalling contacts of the GV2 circuit-breakers?

                      GV2ME, GV2P, GV2L, GV2LE, GV3P and GV3L circuit-breakers can be fitted with the following optional fault indicating contact blocks:
                       

                      GVAD0110
                      GVAD0101
                      GVAD1010
                      GVAD1001

                      These blocks comprise of fault signalling contacts and instantaneous auxiliary contacts

                      GVAD0110

                      A N/O instantaneous auxiliary contact (terminals 53-54), closed when the device is energized and open when the device is de-energized

                      A N/C fault signalling contact (terminals 95-96), closed if there is no fault, open when a fault (magnetic or thermal) occurs. 

                      GVAD0101

                      A N/C instantaneous auxiliary contact (terminals 51-52), closed when the device is de-energised and open when the device is energised.

                      A N/C fault signalling contact (terminals 95-96), closed if there is no fault, open when a fault (magnetic or thermal) occurs. 

                      GVAD1010 

                      A N/O instantaneous auxiliary contact (terminals 53-54), closed when the device is energized and open when the device is de-energized.

                      A N/O fault signalling contact (terminals 97-98), open if there is no fault, closed when a fault (magnetic or thermal) occurs. 
                       

                      GVAD1001

                      A N/C instantaneous auxiliary contact (terminals 51-52), closed when the device is de-energized and open when the device is energized.

                      A N/O fault signalling contact (terminals 97-98), open if there is no fault, closed when a fault (magnetic or thermal) occurs. 
                       


                      The instantaneous auxiliary contact test is performed by creating a state of transition of the handle actuator between the de-energized position and the energized position.

                      The fault contact test is performed by pressing the test button when the handle actuator is in the closed position.

                      No communication between CNOE-211 and EXEC 2.14E

                      Goals and Symptoms

                      The Compact Exec V2.14 is delivered with Concept V2.6SR2.This Exec does not work with any comms modules like CNOE-211.

                      Facts and Changes

                      Concept V2.6SR2
                      Compact Exec V2.14

                      Causes and Fixes

                      A new exec will be available with Concept V2.6 SR2 patch b.

                      STBNIP2212 Advantys Ethernet NIM Firmware Upgrade - Exec v.2.28, Kernel v.2.01, Web 1.20.01

                      Release Notice

                      NOTICE: EXEC VERSION 2.28 FILES HAVE BEEN REMOVED PENDING FURTHER INVESTIGATION. While upgrading the STBNIP2212 from its existing V2.14 version to V2.27 or V2.28, the user may experience difficulties after the upgrade like loss of saved internal IP address and inability to get IP address while using rolename based DHCP. Note that these issues will be observed immediately after the upgrade. If the STBNIP2212 has been upgraded successfully and is in operation, there are no known issues. The firmware upgrade has been pulled off the website until the next course of action is determined. Note that the STBNIP2212 is currently shipped from the factory with a V2.14 firmware and therefore is not affected.
                      The purpose of this resolution is to inform STBNIP2212 users that the Exec., Kernel, and Web pages have been upgraded to the following:

                      • Exec v.2.28
                      • Kernel v.2.01
                      • Web page v.1.20.01

                      Goals and Symptoms

                      A single file named stbnip2212_upgrade_[k]_v.201_[fw]_v.2.28.07_[web]_v.1.20.01.exe, is now available and will automatically run the loader utility program when executed and prompt the user to enter the IP address of the Ethernet NIM. The Exec, Kernel, and web files will load sequentially and then reboot the NIM when completed.

                      Facts and Changes

                      The new Exec., Kernel and web versions are field upgradable and will work with any STBNIP2212 Ethernet NIM hardware versions. The files for the Ethernet NIM can be found on Planet or as the Attachments to this Resolution.

                      Causes and Fixes

                      The following issues have been resolved in this upgrade:

                      1. The NIM would lockup if an excessive amount of UDP traffic was directed to it.
                      2. Version 2.28 corrects a problem where the Ethernet NIM would sometimes fail to go into Run after a power cycle.
                      3. When power is cycled to an ATV31 when it is connected as a preferred module on an STBNIP2212 island, the ATV31 would come back up operational but the Advantys Configuration software would continue to display the ATV31 as failed. With Exec. v.2.28, the Advantys Configuration software will not show the ATV31 as failed after an ATV31 power cycle.
                      4. Output values in the 'Data I/O' web page would retain their last value if the client communications was stopped, regardless of the fallback state of the output. In this version, the 'Data I/O' values now show INVALID when this condition occurs.
                      5. The STBNIP2212 'I/O Data Values' web page will now display the entire 16 bit field when an Input or Output value is displayed in Binary. The display window on previous versions was too small and would not display the entire 16 bit field.
                      6. The 'Save' option in the web page 'Network Interface Module Register' now works properly.
                      7. The RS232 serial communication port on the Ethernet NIM would respond to any request, regardless of the address in the request. It will now only respond to the appropriate address.
                      8. The RS232 serial communication port on the Ethernet NIM is now approximately twice as fast as when the previous Exec version was installed.
                      9. Can now read STBNIP2212 web page applets using Internet Explorer 7 browsers.
                      10. Assigning an IP via DHCP would take over a minute and a half. With version 2.28, the IP will be assigned via DHCP in approximately 30 seconds.
                      11. I/O modules on an island would fail to go into Ready if 15 or more connections were being made to the NIM during power up.
                      12. Version 2.28 fixes a problem where the 'I/O Data Values' web page displayed incorrect values when 'Virtual Placeholders' were configured.
                      13. The 'Process Image area' did not get set to zero if the network cable was removed from the NIM. Outputs would write the last data if the cable was reconnected. In version 2.28, the Process Image area is now cleared if the cable is disconnected and then reconnected. New data from the client is then written to the outputs.

                      Attachments


                      File: stbnip2212_upgrade_[k]_v.201_[fw]_v.2.28.07_[web]_v.1.20.01.exe
                      (Exec, Kernel, web, and download utility file)

                      Exec files have been removed pending further investigation (10/26/07).


                      Document: NIM Exec Upgrade Procedure v_2_28_7.pdf
                      (Procedure to upgrade the Exec, Kernel, and web files to version 2.28.)
                      (Removed File URL: 188355_300E/NIM_Exec_upgrade_procedure_v2_28_7.zip)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/87ab839daec7d7a7c1257384005d872c/fl_block_5/0.7B0?OpenElement&FieldElemFormat=gif)


                      Document: STBNIP2212 Connection Management Recommendations.pdf
                      (This document provides recommendations when multiple numbers of connections must be opened to the STBNIP2212.)
                      (Removed File URL: 188355_300E/STBNIP2212_Connection_Management_Recommendations.zip)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/87ab839daec7d7a7c1257384005d872c/fl_block_5/0.18AA?OpenElement&FieldElemFormat=gif)


                      Document: Concerns when upgrading to 2.28.pdf
                      (If the NIM is configured to obtain its IP via DHCP, Exec versions 2.27 and higher will start in FDR mode. This document explains the steps required to prevent 'user defined web parameters' from being reverting back to default on powerup.)
                      (Removed File URL: 188355_300E/Concerns_when_Upgrading_from_Exec_v2_14_to_v2_28.zip)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/87ab839daec7d7a7c1257384005d872c/fl_block_5/0.2D60?OpenElement&FieldElemFormat=gif)


                      Resolution 187313 - MAC derived IP.pdf
                      (This document describes how to prevent a condition where the STBNIP2212 will default to its MAC derived IP address when it's power cycled using Exec. versions 2.27 or higher.)
                      (Removed File URL: 188355_300E/Resolution_187313_-_MAC_Derived_IP.zip)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/87ab839daec7d7a7c1257384005d872c/fl_block_5/0.4068?OpenElement&FieldElemFormat=gif)
                       


                      Legacy KB System (APS) Data: RESL188355 V3.0, Originally authored by DaDz on 10/06/2007, Last Edited by DaDz on 10/30/2007
                      Related ranges: Advantys STB