GV2G445

4 Tap Offs Busbar Gv2 63A 45mm Pitch

Catalogue Number: GV2G445
GV2G445
Retail
$160.48
RRP (Inc. GST)

Specifications

hide show
Range of product
  • TeSys fuse-disconnector
  • TeSys D
  • TeSys K
  • TeSys GV2
  • TeSys U
    • Range
      Linergy
      Product name
      FT
      Device short name
      GV2G
      Product or component type
      comb busbar
      Accessory / separate part category
      connection accessory
      Poles description
      3P
      Range compatibility
    • TeSys D
    • TeSys GV2
    • TeSys K
    • TeSys U
      • Number of tap-offs
        4
        [Ith] conventional free air thermal current
        63 A
        Connection pitch
        45 mm
        Mounting location
        on terminal
        [Ui] rated insulation voltage
        690 V
        Length
        179 mm
        Net weight
        0.077 kg
        Compatibility code
        GV2G
        Unit Type of Package 1
        PCE
        Number of Units in Package 1
        1
        Package 1 Weight
        78 g
        Package 1 Height
        1 cm
        Package 1 width
        3.5 cm
        Package 1 Length
        18 cm
        Unit Type of Package 2
        S01
        Number of Units in Package 2
        60
        Package 2 Weight
        4.885 kg
        Package 2 Height
        15 cm
        Package 2 width
        15 cm
        Package 2 Length
        40 cm
        Sustainable offer status
        Green Premium product
        REACh free of SVHC
        Yes
        EU RoHS Directive
        Compliant
        Toxic heavy metal free
        Yes
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
        X
        Environmental Disclosure
        ENVPEP111252EN
        Warranty
        18 months

        Documents & downloads

        hide show
        Filter items
        • All

        • CAD Files and Packs

        • Product Brochures

        • Technical Data Catalogues

        • Product Environmental

        • Installation Instruction

        • Data Bulletin

        • Declaration of Conformity

        • eTechPub

        Frequently Asked Questions

        hide show

        What does Pitch refer to in regards to the GV2G busbar system?

        Issue: 
        Need to know what 45mm, 54mm, and 72mm pitch means

        Product Line:
        GV2 Manual Starters

        Environment:
        n/a

        Resolution:
        The pitch is the spacing between slots.  In order to select the correct pitch, total up the width of the device, plus any side mounted auxiliaries.  Use the total width for selecting the proper pitch. The busbar pitch selection must be the same or greater than the sum of device and auxiliaries.

        What is the current rating of the GV1G02?

        Issue:
        GV1G02 electrical ratings

        Product Line:
        GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Selection

        Environment:
        Additional GV2 Wiring Accessories

        Resolution:
        25 amp maximum

        What is the short circuit current rating for TeSys GV2G Comb Busbar.

        The short-circuit current withstand rating (KA) of Tesys Comb Busbar is compatible with the breaking capacity of Motor Protection Circuit Breakers (MPCB) of GV series. The GV Series Comb Busbar does not have a conditional short-circuit current rating.

        The maximum permissible peak current for GV2G*** Series Comb Busbar is 11KA and for GV3G*64 series Comb Busbar is 20KA.

        Example: Use a circuit breaker or fuse in upstream of the Tesys GV2G for a short circuit value up to 11KAmps as the permissible peak current of GV2G354 is 11KA.

        GV2P disconnect options

        Issue:
        What is the product number for a complete through-the-door disconnect device for a GV2P

        Product Line:
        GV2P Manual Starters and Protectors

        Environment:
        US product

        Cause:
        Digest 176 is unclear as to what is a complete mechanism with shaft and handle

        Resolution:
        There are three devices which include mechanism, shaft and handle:
        GV2APN01 has a NEMA 1, 12 rating and is black
        GV2APN02 has a NEMA 1, 12 rating and is red/yellow
        GV2APN04 has a NEMA 3R, 4, 4X rating and is red/yellow

        How to order GV2MCK04?

        Issue:
        GV2MCK04 components

        Product Line:

        Motor Starters and Protectors

        Environment:
        PowerPact™ Manual Starters

        Resolution:
        GV2MCK04 is a European reference only.  To order in North America, order the two components and assemble in the field. 
        This consists of part numbers 
        GV2MC01 and GV2K04.

        What “TeSys D” style accessories are supported by TeSys island?

        Issue:  
        TeSys Island and TeSys D compatibility 

        Product Line: 
        Tesys Island

        Environment:
        Digital multifunctional load management solution 
         
        Resolution:
        • Power Devices are capable accepting reversing kit with mechanical interlock and power connections matching the frame sizes.

        LAD9R1 (LAD9V2+LAD9V5+LAD9V6)
        LAD9R3 (LAD4CM+LA9D65A69)

        • Power Devices are compatible, when used with other Power Devices of the same size range, with following power distribution accessories

        GV2G245
        GV2G254
        GV2G345
        GV2G354
        GV2G445
        GV2G454
        GV1G09

        Can the GV* starters be used on 50 hertz applications?

        Issue:
        GV* Starter for 50/60hz application

        Product Line:
        Motor Starters and Protectors

        Environment:
        PowerPact™ Manual Starters

        Resolution:
        Yes, these starters are rated for 50/60 hertz.

        This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

        What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

        Issue:
        Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

        Product Line:
        Contactors and Starters IEC

        Environment:
        Tesys D contactors and GV manual starters

        Cause:
        Spacer required

        Resolution:
        Compensation plate catalog number GV1F03, requires 2 pieces snap together.

        Is a padlocking device available for the GV2MC** type enclosures?

        Issue:
        Padlocking device for GV2MC Enclosures

        Product Line:
        TeSys GV2 Manual Starters and Protectors

        Environment:
        n/a

        Resolution:
        Yes, use the GV2V01. When this is padlocked, the starter is automatically in and will remain in the OFF position.

        Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

        Issue:
        Mounting adaptor for GV2 and LC1D contactor

        Product Line:
        Motor Starters and Protectors

        Environment:
        TeSys GV Manual Starter and Protectors
        Tesys D Contactors
         
        Resolution:
        The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

        Are explosion proof enclosures available for GV manual motor starters.

        Issue:
        NEMA 7/9 rated enclosure for GV manual motor starters

        Product Line:
        Tesys GV Motor Starters and Protectors

        Environment:
        TeSys™ GV Manual Starters and Protectors

        Resolution:
        No hazardous duty enclosures are available for the GV product line.
        For explosion proof applications consider the Class 2510 Type M or Type T offering.

        Are EasyPact CVS circuit breakers for sale in the USA or Canada?

        Product Line:
        EasyPact CVS circuit breakers

        Cause:
        This breaker is popular overseas and there is interest in the US

        Resolution:
        There are no plans for a general release of the EasyPact CVS circuit breaker line in North America.