Intercon.Block.For K.Cont

Intercon.Block.For K.Cont

Intercon.Block.For K.Cont

Item Number: GV2AF01

Retail
$49.51
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys GV2

Range

Linergy

Product or component type

combination block

Product compatibility

  • LP1K
  • LC1K
    • Sustainable offer status

      Green Premium product

      Warranty

      18 months

      Physical

      Range compatibility

    • TeSys K
    • TeSys GV2
      • Quantity per set

        set of 10

        Net weight

        0.02 kg

        REACh free of SVHC

        Yes

        EU RoHS Directive

        Compliant

        Toxic heavy metal free

        Yes

        Mercury free

        Yes

        RoHS exemption information

        Yes

        China RoHS Regulation

        X

        Environmental Disclosure

        ENVPEP111252EN

        Others

        Product name

        FT

        Device short name

        GV2AF

        Accessory / separate part category

        connection accessory

        Poles description

        3P

        Compatibility code

        GV2AF

        Unit Type of Package 1

        PCE

        Number of Units in Package 1

        1

        Package 1 Weight

        12 g

        Package 1 Height

        3.7 cm

        Package 1 width

        4.1 cm

        Package 1 Length

        5.5 cm

        Unit Type of Package 2

        BB1

        Number of Units in Package 2

        10

        Package 2 Weight

        153 g

        Package 2 Height

        8 cm

        Package 2 width

        9 cm

        Package 2 Length

        12 cm

        Unit Type of Package 3

        S02

        Number of Units in Package 3

        120

        Package 3 Weight

        2.148 kg

        Package 3 Height

        15 cm

        Package 3 width

        30 cm

        Package 3 Length

        40 cm

        WEEE

        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
        Show all specifications

        Documents & downloads

        hide show
        Filter items
        • All

        • CAD Files and Packs

        • Product Brochures

        • Technical Data Catalogues

        • Installation Instruction

        • Data Bulletin

        • eTechPub

        Frequently Asked Questions

        hide show

        What is the equivalent of GV2AP01 and GV2AP02 rotary handle

        The equivalent of GV2AP01 and GV2AP02 rotary handles are GV2APN01          
         and GV2APN02 respectively.Refer attached file for more details

        Protection Rating for GV2E01

        Issue:
        What rating does the GV2E01 give when used with the GV2MC01 or GV2MP01 enclosure

        Product Line:
        GV2 Enclosure Accessories

        Environment:
        US Product

        Cause:
        The IP rating is not specified in the Digest 176

        Resolution:
        When used with the GV2MC01 or GV2MP01, this kit will give a IP55 rating.

        Which enclosures can the GV2E01 sealing kit be used on?

        Issue:
        Which enclosures can the GV2E01 sealing kit be used on?

        Product Line:
        IEC Manual Starters/Protectors - GIC Product

        Environment:
        US Product

        Cause:
        Product Application

        Resolution:
        GV2MC01 and GV2MP01.

        Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

        Issue:
        Mounting adaptor for GV2 and LC1D contactor

        Product Line:
        Motor Starters and Protectors

        Environment:
        TeSys GV Manual Starter and Protectors
        Tesys D Contactors
         
        Resolution:
        The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

        What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

        Issue:
        Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

        Product Line:
        Contactors and Starters IEC

        Environment:
        Tesys D contactors and GV manual starters

        Cause:
        Spacer required

        Resolution:
        Compensation plate catalog number GV1F03, requires 2 pieces snap together.

        Is a padlocking device available for the GV2MC** type enclosures?

        Issue:
        Padlocking device for GV2MC Enclosures

        Product Line:
        TeSys GV2 Manual Starters and Protectors

        Environment:
        n/a

        Resolution:
        Yes, use the GV2V01. When this is padlocked, the starter is automatically in and will remain in the OFF position.

        GV2P disconnect options

        Issue:
        What is the product number for a complete through-the-door disconnect device for a GV2P

        Product Line:
        GV2P Manual Starters and Protectors

        Environment:
        US product

        Cause:
        Digest 176 is unclear as to what is a complete mechanism with shaft and handle

        Resolution:
        There are three devices which include mechanism, shaft and handle:
        GV2APN01 has a NEMA 1, 12 rating and is black
        GV2APN02 has a NEMA 1, 12 rating and is red/yellow
        GV2APN04 has a NEMA 3R, 4, 4X rating and is red/yellow

        Are explosion proof enclosures available for GV manual motor starters.

        Issue:
        NEMA 7/9 rated enclosure for GV manual motor starters

        Product Line:
        Tesys GV Motor Starters and Protectors

        Environment:
        TeSys™ GV Manual Starters and Protectors

        Resolution:
        No hazardous duty enclosures are available for the GV product line.
        For explosion proof applications consider the Class 2510 Type M or Type T offering.

        What is the part code for the Adaptor to join the GV2P16 to a LC1D09BL

        You can use GV2AF3 or GV2AF4 + LAD31

        Can the GV* starters be used on 50 hertz applications?

        Issue:
        GV* Starter for 50/60hz application

        Product Line:
        Motor Starters and Protectors

        Environment:
        PowerPact™ Manual Starters

        Resolution:
        Yes, these starters are rated for 50/60 hertz.

        This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

        What is the difference between the GV2MC01 and the GV2MC02 enclosures?

        Product Line:
         
        GV Manual Motor Starters and Protectors
         
        Resolution:
        The GV2MC01 has an IP41 rating ( similar to Nema Type 1 ), whereas the GV2MC02 has an IP55 rating (similar to the Nema Type 12 ).

         

        What is the code for a side AUX NO/NC for GV3ME80

        GV3A01