Limiter TeSys GV1L3 for circuit breaker TeSys GV2ME & TeSys GV2P
Current limiter for GV2 motor circuit-breaker
Limiter TeSys GV1L3 for circuit breaker TeSys GV2ME & TeSys GV2P
Current limiter for GV2 motor circuit-breaker

Gv2Me-Gv2P Current Limiting

Catalogue Number: GV1L3
Limiter TeSys GV1L3 for circuit breaker TeSys GV2ME & TeSys GV2P
Current limiter for GV2 motor circuit-breaker
Limiter TeSys GV1L3 for circuit breaker TeSys GV2ME & TeSys GV2P
Current limiter for GV2 motor circuit-breaker
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
TeSys GV2
Range
TeSys
Accessory / separate part category
protection accessory
Product or component type
current limiting module
Function of module
increasing the breaking capacity of a circuit breaker
Range compatibility
TeSys GV2
Product compatibility
  • GV2RT
  • GV2ME
  • GV2P
  • GV2L
    • Mounting location
      on top of the circuit breaker
      [Ie] rated operational current
      32 A
      [Ith] conventional free air thermal current
      63 A conforming to IEC 60947-1
      Activation threshold
      1500 A
      Breaking capacity
      <= 100 kA depending on protective device
      [Ue] rated operational voltage
      690 V AC 50/60 Hz
      [Ui] rated insulation voltage
      690 V AC 50/60 Hz conforming to IEC 60947-1
      Connections - terminals
    • screw clamp terminals 1 x 1.5-25 mm² rigid
    • screw clamp terminals 2 x 1.5-10 mm² rigid
    • screw clamp terminals 1 x 1.5-25 mm² flexible without cable end
    • screw clamp terminals 2 x 1.5-10 mm² flexible without cable end
    • screw clamp terminals 1 x 1.5-16 mm² flexible with cable end
    • screw clamp terminals 2 x 1.5-4 mm² flexible with cable end
      • Tightening torque
        2.2 N.m
        Net weight
        0.13 kg
        REACh Regulation
        Free of Substances of Very High Concern above the threshold
        REACh free of SVHC
        Yes
        EU RoHS Directive
        Compliant
        Toxic heavy metal free
        Yes
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
         Pro-active China RoHS declaration (out of China RoHS legal scope)
        WEEE
        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
        California proposition 65
        WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
        Warranty
        18 months

        Documents & downloads

        hide show
        Filter items
        • All

        • Product Brochures

        • CAD Files and Packs

        • Movies

        • Technical Data Catalogues

        • Catalog Page

        • Technical Leaflet

        • Installation Instruction

        • Data Bulletin

        • Handout

        • Product Environmental

        • Specification for Tender

        • eTechPub

        • Marine Certificate

        • White Paper

        • Certificates (MSDS)

        • Declaration of Conformity

        • Software - Released

        Frequently Asked Questions

        hide show

        Is it possible to use the current Limiter LA9LB920 or GV1L3 with Tesys GV3 range of MPCB to increase the breaking capacity.

        LA9LB920 and GV1L3 current limiter are dedicated to Tesys GV2 Motor Protection Circuit Breaker (MPCB) product range and can be used with MPCB rated up to 32A (maximum current range of Tesys GV2 products).
         
        The new Tesys GV3 range does not have current limiter to increase its breaking capacity.
         
        If higher breaking capacity for Tesys GV3 is needed, use in association with fuses can increase the breaking capacity of the system up to the fuse performance breaking capacity.

        Do the GV7 and the LR9F trip on phase loss?

        Yes they do, though their trip time for "unbalanced phases" is much faster than that of the conventional thermal magnetic overloads, such as GV2/3 series or LRD series.

        The GV7 and LR9F series will both trip after 4 seconds (+ or - 20%) on phase loss where an LRD or GV2/3 can keep running for up to 2 hours unless an overload is detected in the remaining phases.

        TSXCCY1128 - How to know online the last Firmware version with the IE

        With the IE and the following table you can know the SV version inside
        SV1.0 IE 19
        SV1.1 IE 20
        SV1.2 IE 21
        SV1.3 IE 22

        To show the IE version in connected mode on the module TSXCCY1128, typed : CTRL, SHIFT, F11 .
        IE will appear near the SV.


        Legacy KB System (APS) Data: RESL192736 V1.0, Originally authored by JeCa on 09/12/2008, Last Edited by JeCa on 09/12/2008
        Related ranges: Modicon Premium

        Is there an additional light diffuser available for XVB and XVD illuminated Tower Beacons

        Yes, the light diffuser, part number XVBZ18 (consisting of two half-cylinders) can be placed in the illuminated lens unit so as to create a new light prism.
        The assembly offers more diffuse light, thus enhancing visual comfort. It can also be used with illuminated lens units with flashing LEDs.

        Caution! The XVBZ18 diffuser cannot be fitted on:

        • Incandescent bulbs (because of the heat released)
        • Flash discharge tubes (XVBC6, XVBC8 and XVDC6)
        • XVBL, XVDL3 and XVDL4 beacons
        • It is also incompatible with the whole range of XVP and XVE indicator banks and beacons

        Compatible products on which the diffuser can be fitted are:
        • XVB illuminated lens unit with built-in LED
        • XVB beacon with built-in LED
        • XVD indicator bank with pre-wired LED
        • XVB and XVD LED bulb with BA15d base fitting

        The diffuser is fitted as standard to built-in LED illuminated lens units part number XVBC2B*D (where * is the lens colour)

        WIll the motor or terminal strips on the output side of a drive affect the SCCR rating of the drive?

        Issue:
        WIll the motor or terminal strips on the output side of a drive affect the SCCR rating of the drive?
         
        Product Line:
        Altivar Variable Frequency Drives
         
        Environment:
        All Altivar drive products.
         
        Cause:
        Information not available in current literature.
         
        Resolution:
        No.  The SCCR annex is an input current rating.  Terminal strips, disconnect switches, contactors, or other approved equipment connected to the output of the drive will not affect the input SCCR rating of the drive itself.  Note that the Altivar drive is not approved as a current limiting device and therefore, the overall SCCR rating of the panel the drive is installed in will be the SCCR rating of the lowest rated device in the panel.
         









         

        What is the difference between the XVAC211 and the XVAC21?

        Issue:
        What is the difference between the  XVAC211 and the XVAC21?

        Product Line:
        Tower Lights

        Environment:
        All products

        Cause:
        Product Features

        Resolution:
        They are the same cover and base units, but the XVAC21 does not include a gasket .


         

        How can a custom length of support tube be achieved with the XVB Indicating Bank?

        Issue:
        Needs to know how How can a custom length of support tube be achieved with the XVB Indicating Bank

        Product Line: 
        Push Buttons and Operator Interface

        Environment:
        22 mm Push Buttons

        Resolution:
        Use the conduit adapter part number XVBC00 and the desired length of .5`` (1/2) conduit.