coupling cond pvc expn 25mm

Solid Fittings - PVC, Expansion Couplings - Flexible, 25mm

Catalogue Number: F251/25
coupling cond pvc expn 25mm
Colour: Grey
Colour: Per UOM Std.
  • Electric Orange 1 PCE
  • Grey 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Range of product
Series F251
Material
PVC (polyvinyl chloride)
Product destination
diameter: 25-25 mm tube
Length
81-81 mm
Standards
AS/NZS 2053
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Frequently Asked Questions

hide show

What are the part numbers of slip type expansion couplings?

Slip Type Expansion Couplings are available from 16mm through to 50mm.The part numbers of slip type expansion coupling are as follows:
16mm = 251/16
20mm = 251/20 *
25mm = 251/25 *
32mm = 251/32
40mm = 251/40 *
* = only available in Grey
Where long conduit runs are likely to be exposed to wide variations in temperature, it is recommended that expansion couplings be used at each join. It is not recommended that Slip Type Expansion Couplings be used where the conduit run is exposed to the weather. Standard colour is Grey (GY).
Dimension details are attached.
 

LH4N125QN7 - Replacement?

ATS01N222QN 

Can the A9C20732 switch 400V?

No, it is only rated to switch 250V

What are the part numbers for the 25mm PVC saddles and spacers?

The part numbers are 261/25 for the saddles and 261S25 for the spacers. 

Some of the key features are:
  • 63mm Length x 20mm Width x 29mm Overall Height
  • 48mm Mounting Centre
For further information please visit https://www.clipsal.com/Trade/search-results?q=261/25



 

Does the 1240/25 series come with gaskets?

No, they are light duty. Buy the 1240HL25 to obtain a heavy duty lid and gasket , or if gasket is required for retro fit then buy 1240GT
For more information on this product range please visit the Clipsal web site on the link provided
https://www.clipsal.com/Trade/search-results?q=1240

Which PDL Keystone Clip fits 600 Series ?

 The PDL 615MKC clip fits all 600 Series standard plates.  

Is there 125x125 mini trunking available.

no, biggest mini trunking size available is 150x75

Is the Clipsal 279C20 20 mm Gland UV rated ?

 No  - only UV stabalised

What is part number for 15amp switch mech for flourescent lighting?

The part name is 30USM-WE

Whati s pitch thread for part number 1245/25?

Pitch thread is 1.5mm

What is the dimensions for a B31A (Stainless Steel) and BB31A (Polished Brass) Architrave Switches ?

The dimensions are:
Length x 140mm
Width x 35mm
Depth x 30mm
Mounting Centres x 125mm

Is the separate switch in the WSC227/2X-RG separately wired?

No it is not anymore, it used to be in a previous design.

What is the part number for fan controller knob only to suit Prestige 3 speed fan controller?

The part name is as follows: P2031VF3CBKB-WE

Is there any difference in dimension between the PT55F & PT80F?

There is no difference between the dimensions of these two units

What is the largest cable size for the PDL 56P420 plug?

The largest cable size for the 56P420 plug is 16.4mm

Red and Green pins to suit TC15/24, TC15/15/24 and TC15/15/7D?

The red and green pins to suit these timers are TC32PINS-RD or TC32PINS-GR. These are sold as a pack of 100.

Do we do head only for XCSTE5342?

No, Unfortunately we don't due to safety reasons.

Does the 4FCC30 come with Metal backing plate?

The 4FCC30 does not have a metal backing plate

What is the thread type on a 1235/25?

The thread type on a 1235/25 is BS - British Standard.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=1235/25 

Could not remove directory \usr\Cfg message when upgrading M241/251 firmware

  • When upgrading using Controller Assistant and USB cable, error message "Could not remove directory \usr\Cfg" is displayed.
  • When upgrading using SD card "Delete "/usr/*" (line 1) returned cleaning error" appears in SCRIPT.log file.

This is because some corrupted files can not be deleted.
To delete these files " Format "/usr" " should be added to SD card script.

In firmwares starting from v4.0.2.52 " Format "/usr" " is added automatically by Controller Assistant when generating SD cards.
 

Preventa XCS_EAC certificate of the XCS electromechanical switches, including the XCSDMP, XCSDMC and XCSDMR magnetic switches

Please find attached Russian EAC certificate of our XCMD, XCK, ... XCS safety switches, including the XCSDMP/C/R magnetic switches, valid up to January 2020. It replaces the Gost certificate.

What can I do if the PLC TM221 reboots continuously after have updated it with the firmware 1.3.2.1 SP1?

This issue can be solved downloading any application in the PLC TM221 via USB in power less mode ( no power supply connected )
After that the issue will not appear anymore

How can you get Altivar ATV16 to hold in place without using mechanical holding brake?

Issue: How can you get Altivar ATV16 to hold motor in place without using mechanical holding brake?
 
Product Line: ATV16
 
Environment: All
 
Cause: N/A
 
Resolution: The ATV16 Can`t produce 100% torque at zero speed so the drive will not work in this type application.


 

Procedure for Adding a Reset Task in System Manager Software

See attached PowerLogic Knowledge Base Procedure document.
Procedure for Adding a Reset Task in System Manager Software.pdf

Original article#1885


Legacy KB System (APS) Data: RESL182793 V1.0, Originally authored by DaMi on 03/15/2007, Last Edited by DaMi on 03/15/2007
Related ranges: SMS 4.x, SMS 3.x

How to change onboard alarm names for Powerlogic meters using ION setup

Issue
A custom onboard alarm name is required in the meter's alarm log. 

Product Line
ION Setup
PM800 Series Meters
CM4000 Series Meters
CM2000 Series Meters

Environment
ION Setup Alarm Configuration

Cause
The default alarm names may not be desirable for all onboard alarms.

Resolution
See the attached document for instructions on customizing the name of an onboard alarm.

What is the time-out for the Advanced Reports Web page?

Advanced Reports has 2 web page time-outs. The reports creation process has a web page time-out of 10 minutes. The web session for Advanced Reports will time-out after 15 minutes of inactivity. Once each time-out has been reached the user will be required to login. The settings can not be changed.

  • Last Revised: 7/9/2007

    Public

    All content © 1992-2007 Schneider Electric


Legacy KB System (APS) Data: RESL186986 V1.0, Originally authored by KBAdPM on 07/11/2007, Last Edited by KBAdPM on 07/11/2007
Related ranges: SMS Add-on

Can ION Enterprise and SMS Co-Exist on the same Computer?

Yes they can, but there can be difficulties with enabling the software to operate correctly. The most reliable method is to first install SQL/SMS. Next, install ION Enterprise and MSDE (the two database engines will co-exist on the same system). There are complications with the sa password if the two Suites are running on a unified SQL database.
Also, SMS 4.0 SU2 requires .Net 2.0 framework, while ION:Enterprise 5.5 requires .Net 1.1 framework. These can co-exist on the same system, but may require some configuration for their individual needs.

 

It is NOT recommended to run ION Eneterprise and SMS on the same system, but there have been some successfull installations.

 



 

More Information

SMS Installation:

 

https://www.powerlogic.com/literature.cfm?cat_4%20Software_sub_Enterprise=1&cat_4%20Software_sub_For%20Circuit%20Monitors%20&%20Power%20Meters=1&

 

ION:Enterprise Commissioning Guide:

 

https://www.pwrm.com/support/IONEnterprise/

 

 

Original article#16722

Last Revised: June 22 2007

Public

All content © 1992-2007 Schneider Electric


Legacy KB System (APS) Data: RESL186703 V1.0, Originally authored by KBAdPM on 07/06/2007, Last Edited by KBAdPM on 07/06/2007
Related ranges: ION Enterprise V5.5, System Manager 4.0

Can you use the VW3A1101 keypad with the ATS48 soft starters?

Issue:
Can you use the VW3A1101 keypad with the ATS48 soft starters?

Product Line:
Altistart ATS48

Environment:
All

Cause:
Needs to run a 50ft cable run using the VW3A1101 keypad and cat 5 cable to the ATS48 soft starter.

Resolution:
The VW3A1101 keypad is not compatible with the ATS48 soft starter.   The correct remote keypad part number for the ATS48 is VW3G48101.  The standard cable is 3 meters long.  We do not have any test data to support that you can run this cable with a repeater to get a longer cable run out of it.   You will have to test to see if the remote cable can mounted longer than 3 meters.

 

How to sense the communication break between the BMXNOR0200 ( Client/Server ) with any SCADA on IEC or DNP3 Protocol.

The easy method is to use %SW20 Incremental counter ( Unity Pro Software, system word ) mapped to any %MW which is inturn map to data points ( IEC or DNP3 protocol ) Infact there is no direct bit or word for getting the diagnostic communication break or make. This incremental counter ( %SW20 ) is incrementing always even if the CPU is in stopped mode. So the point is to read this running counter value in SCADA. Whenever the cable is disconnected the reading in the SCADA will hold the last value and will not be incremented. This fixed value in SCADA will be the alarm to say the communication is broken between the SCADA and the BMXNOR0200. Here the programmer in SCADA has to compare the current value with the last 2 seconds value. If the value is same means its fixed and there is communication break. If the value is not fixed and is incrementing means that the communication is healthy.

Video: Why do Modbus Tester and the EGX webpage reading values differ from the front panel of the meter?

Issue
When I read the value from the front display of a meter it looks correct however when I read it the value as a register read from the EGX webpage or the Modbus Tester tool the value returned is vastly different.

Example: The front panel of the meter displays -9,173 kVAR yet the direct register reads yield a value of 56362

Product Line
EGX100
EGX300
Modbus Tester

Environment
Reading and Interpreting Modbus Registers

Cause
The registers are stored in the meter as a signed 32 bit value but the EGX register read and Modbus Tester treat the register as an unsigned 32 bit value.

Resolution
See the provided video for a detailed explanation on why the values being read are different and how to find the correct value.

Does the C2025VC fit the outlet C2025?

No, Unfortunately they made a second version. The replacement part is C2025VC2.
The first thing you'll notice about the C2000 classic series is the cover, which comes in a choice of superb metal finishes and classic coloured plastic mouldings. This cover not only looks attractive, it also hides all mounting holes and is easily removed to enable you to paint right up to the edge of the grid plate without having to worry about marking the cover. When decorating is complete, the cover is simply replaced for a perfect finish. As C2000 classic series covers and grid plates can be mixed and matched, you can produce many combinations to match the particular decor theme you want to create.
Some of the key features for the C2025VC2 are:
  • New designt
  • Standard size
  • Identification cover
  • For twin switched socket
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2025VC2
 

How to obtain the MAC address of a Magelis HMI?

Title
Magelis HMI MAC address
 
Issue
Magelis HMI MAC address
 
Product Line
Magelis HMI
 
Environment
Vijeo Designer
 
Cause
N/A
 
Resolution
 For a Magelis HMI, the Media Access Control (MAC) address is a unique 12-digit hexadecimal value associated with a network card. MAC Address is also known as a hardware address or a physical address.
At run time, you can view the MAC address of a target machine that supports Ethernet using either scripts or the Runtime Configuration Menu.

To view the MAC address using the Runtime Configuration Menu:
Open the Runtime Configuration Menu. For more information, see Section 26.2, Displaying the Runtime Configuration Menu.
In the Offline tab, click the Network button to open the Network menu.
Touch the MAC/DNS tab at the top of the Network menu.
The MAC Address is displayed in the Network MAC/DNS tab.
You can also enable or disable the DNS from this screen.

To view the MAC address using scripts:
Use the MAC_Address_1 and MAC_Address_2 parameters with the system method Sys.getInfoString(int param) in the editor. See Section 18.9.1.5, System Method: Sys,getInfoString.

NOTE: Be aware that some targets have two MAC Addresses, because they contain two network cards and each Ethernet card will have a unique MAC address
 

How to calculate Energy readings from the raw Integer register data on an Energy Meter

Issue
The energy values are stored across two 16-bit integer registers on an energy meter. 

Product Line
Energy Meter

Environment
Reading and converting Modbus register values

Resolution
The Energy Meter stores energy across two 16-bit integer registers.

Register #1 and Register #2 (Modbus address 257/258 for Register #1 and 259/260 for Register #2). Register #2 is the High WORD and Register #1 is the Low WORD. 

The Multiplier/Divisor table states that both of these registers must be divided by 32 to obtain the real value from the raw data.
The Multiplier/Divisor should NOT be applied to both registers. It is applied to the final value of both registers.

To calculate the Energy the registers must first be arranged as the register list states [2] is the High word and [1] is the Low word.

To make [2] the High word it needs to be shifted to the left 16 bits.
To accomplish this multiply the value in [2] by 65,356.
You will then add this value to the value in [1].
The final value will be divided or multiplied by the correct scaling value. Please see the example listed below.

For this example we will assume an Energy Meter with 300 amp CTs. According to the Integer Multiplier/ Divisor table, 300 amp CTs will give a divisor value, (d), of 32 and a multiplier value, (m), of 0.03125.
We will assume the following register values.
Register #1 = 29,586
Register #2 = 31

Using Divisor Table
kWh = ([R2]*65,536+[R1])/d
kWh = (31*65,536+29,586) / 32
kWh = 64412.56

Using Multiplier Table
kWh = ([R2]*65,536+[R1]) * m
kWh = (31*65,536+29,586) * 0.03125
kWh = 64412.56

*Note the divisor will not always be 32 and the multiplier will not always be 0.03125. For the correct values please see the Integer Multiplier Table.
 

170ENT11001 Goes into SAFE MODE if the IP is Assigned via DHCP

Goals and Symptoms

The purpose of this resolution is to inform 170ENT11001 Ethernet Communication Adapter product users that a workaround is available so the module does not go into SAFE MODE when its IP address is assigned using DHCP.

  •  

Facts and Changes

A condition exists with the 170ENT11001 in Exec. versions 1.04 and lower where the Ethernet Communications Adapter will go into SAFE MODE if the IP is assigned by an NOE or ETY DHCP server.

SAFE MODE is a condition where the I/O communications between the 170ENT11001and the I/O Base are intentionally disabled and the outputs are set to their reset state.

Causes and Fixes

If the ENT11001 is configured with a ROLENAME, it will send out DHCP Discover messages to obtain its IP address from a DHCP server. After the NOE/ETY DHCP server assigns the IP, there is an FDR (Faulty Device Replacement) requirement to upload specific files from the ENT11001 flash memory via FTP. One of these files contains information about the 'Holdup Time' and 'Reservation Time', but these values are not stored in flash memory when the module is powered up new out of the box. Therefore, as a workaround, the user must go to the "Configure Momentum IO" web page and select "Configure Communication Adapter Parameters" (see diagram). The user must then click on 'Save' to save the 'Holdup and Reservation' Time values to flash. Once this action has been accomplished, it does not have to be repeated unless the Holdup or Reservation Time value needs to be changed. The IP can now be assigned via DHCP at any time and the IO will become operational.


Legacy KB System (APS) Data: RESL175918 V1.0, Originally authored by on , Last Edited by on
Related ranges: Modicon Momentum

Which firmware version supports functionality of the PM8 Ethernet Communication Card (PM8ECC) with the Series 800 Power Meter (PM8)?

Issue
Which firmware version supports functionality of the PM8 Ethernet Communication Card (PM8ECC) with the Series 800 Power Meter (PM8)?
 
Product
PM800 Series Power Meter, PM8ECC
 
Environment
Mounting PM8ECC on PM800 Series Meter
 
Cause
The PM800 series meters had been out several years before the PM8ECC became available, so the firmware may not be the latest. As a result, PM8ECC will not function correctly.
 
Resolution
The Series 800 Power Meter (PM8) MUST have 10.6 firmware or later in order to support the functionality of the PM8 Ethernet Communication Card (PM8ECC).

To verify the firmware version from the front panel of the meter, follow the steps below.
1. Press MAINT > DIAG > METER.
2. Verify that the number before OS, RESET, and DL is 10.600 or higher.
3. If the meter firmware is not up-to-date, then meter firmware must be updated.  One or all three firmwares may need upgrading (OS,RS, or DL).

NOTE: In order to upgrade the firmware, you will need the Download Firmware Upgrade Utility (DLF3000), which is provided on the
PM8ECC Technical Library CD-ROM or can be downloaded from  Firmware Upgrade - Instructions and Downloads.  
If you need assistance using DLF3000, refer to the Help file.

Access to firmware upgrade instructions, including a how-to video and a link to the latest firmware can be found at:  Firmware Upgrade - Instructions and Downloads

Additionally, supporting documents and file downloads on this and a wide variety of other products and topics may
be obtained using the search function found at the  Download Center

Is there a replacement or alternative for the 30 pair, distribution enclosure 3100E30IDF?

Yes, the replacement/ alternative for a 30 pair, distribution enclosure 3100E30IDF is 3100F540MDFC Clip-on Distribution Frame.
Some Key Features are :
  • 500 pair frame - accommodates 50 modules and 4 label holders
  • Fully compatible with leading clip-on style frames
  • Accepts all leading clip-on style modules
  • Links with other frames in the Clipsal Dataco mms High Density Portfolio
  • Metal covers
For more information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=3100F540MDFC


 

How to connect PLC/HMIs remote after a Router/Modem?

In SoMachine V4.1 you can make remote connection by using connection mode NodeName via NAT or IP Address via NAT.
 You can use one of the remote connected PLCs or HMI as NAT Router.
This remote Nat Router must be reached by port 1105.
If the PLCs are behind a Firewall you can reach this PLC by forwarding port 1105 to the PLC with the NAT router functionality.

At SoMachine add the IP address of the Firewall/Router as NAT Address