Metal Clad Switched Socket Outlets, Multi Phase, 500V, 32A, 4 Round Pins

Metal Clad Switched Socket Outlets, Multi Phase, 500V, 32A, 4 Round Pins

Metal Clad Switched Socket Outlets, Multi Phase, 500V, 32A, 4 Round Pins

Item Number: E432C

Retail
N/A
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

  • Wilco
  • E
    • Product brand

      Clipsal

      Device application

      power supply

      Physical

      Number of poles

      4

      Number of power socket outlets

      1 protective cover

      [In] rated current

      32 A

      [Ue] rated operational voltage

      500 V AC

      EU RoHS Directive

      Compliant

      Toxic heavy metal free

      Yes

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

       Pro-active China RoHS declaration (out of China RoHS legal scope)

      Others

      Unit Type of Package 1

      PCE

      Number of Units in Package 1

      1

      Package 1 Weight

      3345.3 g

      Package 1 Height

      147 mm

      Package 1 width

      166 mm

      Package 1 Length

      377 mm
      Show all specifications

      Documents & downloads

      hide show

      Frequently Asked Questions

      hide show

      Is there any alternative for the old Moduline series EA31C 130mm high for gpo shroud kits and covers?

      There is no offer at all for the EA31C series as this was discontinued a long time ago and had a drop in lid which is also discontinued and there is no option for power shroud etc.

      Getting E4303 on the LXM32

      Issue:
      Getting E4303 on the LXM32

      Product Line:
      LXM32

      Resolution:
      This means that the LXM32 drive cannot monitor the temperature of the motor. It's a warning that shows when using certain 3rd party motors.

      Install Shield error '432' when trying to install ION Setup 2.1

      This appears to be an Install Shield error. The following KB article resolvs the issue:
      https://consumer.installshield.com/kb.asp?id=Q110613




      Last Revised: November 13, 2007
      Applies To: ION Setup
      Public
      All content © 1992-2007 Schneider Electric


      Legacy KB System (APS) Data: RESL189161 V1.0, Originally authored by KBAdPM on 11/14/2007, Last Edited by KBAdPM on 11/14/2007
      Related ranges: ION Setup 2.1

      What are the Dynamic Load ratings and Shipping Load ratings for NetShelter CX cabinets?

      Issue:
      A customer needs to know how much weight they can load into their NetShelter CX for static installation, dynamic installation (rolling on flat surface) or to ship loaded with equipment. 

      Product Line:
      NetShelter CX

      Environment: 
      All versions and serial ranges.

      Cause:
      A customer wants to load the cabinet and move it, or ship it. 

      Resolution: 

      Static Load Weight Rating is the maximum weight of the cabinet, plus installed equipment (with the feet locked), in it's final location. 

      Dynamic Load is often confused with Shipping Load. These two ratings are different and care should be taken to distinguish between them.

      Dynamic Load Weight Rating is the maximum rolling load of the cabinet. This is the maximum allowable weight of equipment installed in the cabinet during movement from one location to another within the same data center. This assumes level flooring on a smooth surface. Carpet is not a smooth surface.
      In conjunction with the cabinet rating, the applicable ratings of any raised floor or other flooring installed in the data center should not be exceeded.
      Example: a customer who wishes to move a cabinet from one row to another in a data center must remove equipment until the weight is equal to (or below) the Dynamic Load Rating before being moved.  

      Shipping Load Weight Rating is the maximum allowable weight of equipment installed in the cabinet during any shipping process where the cabinet is to be moved outside the data center. Shipping cabinets with equipment installed requires the use of a special cabinet with heavy duty shock packaging. Shock packaging is required to ship a cabinet with installed equipment. Shock packaging contains a cushioned pallet designed to absorb some of the impact forces experienced during the shipping process (truck or rail vibration and impact). This packaging has undergone rigorous testing to ensure safe transport. 

       
      MODEL STATIC LOAD RATING DYNAMIC LOAD RATING SHIPPING LOAD RATING
             
      AR4000MV 704 lbs (320 kg)  458.5 lbs (208 kg) na
             
      AR4018A (X429, X431, X432)  1826 lbs  (830 kg)  970 lbs (441 kg)  na
      AR4018IA (X429, X431, X432)  1826 lbs  (830 kg)  970 lbs (441 kg)  na
      AR4018SP (X429, X431, X432)  1826 lbs  (830 kg)  970 lbs (441 kg)  700 lbs (319 kg) 
             
      AR4024A (X429, X431, X432)  1771 lbs  (805 kg) 928 lbs (422 kg)  na
      AR4024IA (X429, X431, X432)  1771 lbs  (805 kg) 928 lbs (422 kg)  na
      AR4024SP (X429, X431, X432)  1771 lbs  (805 kg) 928 lbs (422 kg)  800 lbs (363 kg) 
             
      AR4038A (X429, X431, X432)  1716 lbs (780 kg)  845 lbs (384 kg)  na
      AR4038IA (X429, X431, X432)  1716 lbs (780 kg)  845 lbs (384 kg)  na