Switch Time Delay

White Electric | Switch Time Delay

Switch Time Delay

Item Number: E319-WE

Retail
$166.03
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Range of product

Series 319

Surface finish

glossy

Physical

Device presentation

basic element with full cover plate

Device mounting

flush

[Ue] rated operational voltage

250 V

Rated current

10 A

EU RoHS Directive

Under investigation

Environmental Disclosure

ENVPEP120506EN

Material

Material

plastic

Others

Autonomy

0.0083...0.33 h

Network frequency

50/60 Hz

Package 1 Weight

131 g
Show all specifications

Documents & downloads

hide show

Frequently Asked Questions

hide show

What is an E-19 error code on the ATV21/212 drive?

Issue:
 E-19 code on the ATV21/ATV212 drive.

Product line:
Altivar ATV21 ATV212

Environment:
All models, all serial numbers

Cause:
Drive trips with E-19 code.

Resolution:
E-19 error is a communication error between control CPUs on the ATV21/212 drive.  The fault is usually due to a loose connection on the cable connecting the control card and power board.  Another possible cause is that the power board or control board is damaged.  Make sure there is no 24V or 10V supply on VFD being shorted due to wiring.

What can cause an E-19 on an ATV212 drive?

Issue:
E-19 on display

Product Line:
ATV212

Environment:
All models and serial numbers

Cause:
Communication error between control CPU's

Resolution:
This is a CPU Communications Error
Check the environment (electromagnetic Compatibility)
Power down and after the display is blank, remove all control wiring and then reapply power and see if the fault returns.
Check that no external +24v supply is connected to the control terminals.
Open the door and check all the inner connections.
Power cycle the drive and if the fault returns, the drive appears to be inoperative.
 


 

How long does part number 319 run for?

Part number 319 can be run up to 20mins.

What is part number for 319 reverse action?

The part number is  319RA.

What is the maximum time for a 319 timer?

319 Pneumatic timer can be set from 30 seconds to 20 minutes

please see link below for further information

https://www.clipsal.com/Trade/Products/ProductDetail?catno=319

Can the 319 switches be wired in two way?

Yes, the 319 pneumatic switches can be wired in parallel so that they can switch the same load.

For further information please visit https://www.clipsal.com/Trade/search-results?q=319