Combination RCD/MCB, Flush Mount, 2 Pole, 10A, 10mA

Combination RCD/MCB, Flush Mount, 2 Pole, 10A, 10mA

Combination RCD/MCB, Flush Mount, 2 Pole, 10A, 10mA

Item Number: E01/10/2

Retail
N/A
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

  • Clipsal - Series E01
  • Medilec
    • Product or component type

      residual current breaker with overcurrent protection (RCBO)

      Product brand

      Clipsal

      Physical

      [In] rated current

      10 A

      [Ue] rated operational voltage

      240 V AC

      Protection type

      short time short-circuit protection

      Mounting mode

      flush mounting

      Standards

      AS/NZS 3190

      Ambient air temperature for operation

      -10-55 °C

      EU RoHS Directive

      Compliant

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

      Product out of China RoHS scope. Substance declaration for your information

      Others

      Poles description

      2P

      Earth-leakage sensitivity

      10 mA

      Earth-leakage protection class

      class AC

      Network frequency

      50 Hz

      Size

      220 x 175 x 70 mm conforming to DIN 43880

      Package 1 Weight

      1.35 kg
      Show all specifications

      Frequently Asked Questions

      hide show

      What are the dimensions for the wall box for the E01/20/2?

      The dimensions for the wall box for the E01/20/2 are - H198mm x W150mm x D70mm
      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=E01/20/2
      User-added image

      Is part code E05/36/2 still available in NZ

       Yes it is still available but it is an indent

      Why Does the "Press to mute indicator" light stay on, on a E02/10/2?

      RCD/MCB requires to be reset. Therefore, once it is reset the "Press to mute indicator" light should turn off.
      For Further Instruction please find attatched the Install Instructions for Combination RCD/MCB & optional Alarm E01, E02, E01CNN series.

      Some of the Key features are:
      • Multiple 2 tone audible indication
      • Flashing red visual alarm indicator
      • Mute push-button marked press to mute
      • Remote alarm contacts
      • Modular din rail mounted design
      • Standard finish for flush mount is stainless steel
      • < 40 ms trip time
      • Operating tempreture: -10 to 55 deg C
      For further information on this product please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=E02/10/2
       

      Can you set A01/A02 from active to passive?

      Issue: ATV630, Active to passive setting on A01/A02


      Product Line:
      ATV630

      Environment:
      All

      Cause:
      Changing an active input to a non active input on A01/A02

      Resolution:
      No you can not set A01/A02 to passive or non-active
       

      What replaces the line isolation and overload monitor E05/36/2 and E05/48/2?

      The part number for the line isolation and overload monitor is MLHG6. The MLHG6 line isolation and overload monitor replaces both E05/36/2 and E05/48/2.
      The MLHG6 requires a wall box, the part number for the wall box is MLHG6B-AU.
      Some of the key features are:
      • Programmable for current monitoring up to 100A
      • In-built test / verification module
      • Tracks data history of operational mode and faults
      • Fully approved to AS/NZS4510:1999 Isolated Electrical Supplies for Medical Uses
      • Meets requirements for AS/NZS3003:2011 Electrical Installations – Patient Areas of Hospitals
      • Potential to integrate into BMS
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=MLHG6