Quantcast

Dalicontrol Infinity, 5 Pole, Starter Tarter Socket

Dalicontrol Infinity, 5 Pole, Starter Tarter Socket

Dalicontrol Infinity, 5 Pole, Starter Tarter Socket

Item Number: DI-SS

Retail
N/A
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

REACh Regulation

Free of Substances of Very High Concern above the threshold

REACh free of SVHC

Yes

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

envpep090103en

Others

Package 1 Weight

0.2 kg

Package 1 Height

20 mm

Package 1 width

86 mm

Package 1 Length

118 mm
Show all specifications

Frequently Asked Questions

hide show

What is the difference in the Auto 1 and Auto 2 dials of the Powerpact H and J magnetic only MCP?

Issue:
What do the Auto 1 and 2 dials mean on a Powerpact H and J magnetic only breaker?

Product Line:
Circuit breakers

Resolution:
The auto 1 and 2 dials are for the types of motors.
Auto 1 is for squirrel cage type motors with codes A, B, C, and D.
Auto 2 is for EE motors with codes B and E.

What is the breakdown of components for 9001KYK117?

Issue:
Breakdown of components for 9001KYK117  

Product Line:
Harmony Push Buttons

Environment:
Harmony Control Stations

Cause:
Product Features

Resolution:
9001KYK117 components are:
1-9001KY1S1 (red enclosure)
1-9001K15 (break glass operator)
1-9001KA1 (1 open and 1 closed contact)
1-9001KN799RP (legend plate)

Replacement glass discs are 9001K57 (package of five)

Video: How to configure Harmony XVU Tower Light color and illumination settings

Product Line:
XVU Tower/Stack Light XVUC29

Resolution:
On page three of three in the included instructions you will find two boxes.One labled Dial "A" and one labeled Dial "B." Using these tables, select the features that you want. Then set the dials marked "A" and "B" on the top of your XVU unit to match your requirements. To change the dials you will need to use a small, flathead screwdriver.

Is a time delay available for the Masterpact NW/NT undervoltage trip?


Issue:
Need a delay on standard undervoltage relay (UVR) in breaker.

Product:
Circuit Breakers

Environment:
Applies to Masterpact NW/NT breakers.

Cause:
To eliminate circuit breaker nuisance tripping during a temporary voltage dips, operation of the undervoltage trip (MN/UVR) delayed.  This function is achieved by adding a external delay unit (either adjustable or non-adjustable) to the undervoltage trip (MN/UVR) circuit.

Resolution:
Yes. Time delay modules can be used with the NW/NT UVR in the following voltages:

Adjustable (adjustable with dial on the front via pocket screw driver):
 
VoltsCat #
48-60 Vac/dcS33680
100-130 Vac/dcS33681
200-240 Vac/dcS33682
380-480 Vac/dcS33683


Non-adjustable:
 
VoltsCat #
100-130 Vac/dcS33684
200-240 Vac/dcS33685

 

What is the difference between standard and Mission Critical (W) Micrologic trip units? Are the adjustable dials identical?

Issue:
Mission Critical breakers

Product Line:
Circuit Breakers

Resolution:
The trip curves and adjustments for the standard and W trip units are the same.  The difference is that the W trip units have been modified to delay longer before tripping (though still within the curve) in order to provide more withstand capability and coordinate with downstream breakers at higher fault levels.  

More information on the trip units can be found in the instruction bulletin 48940-310-01.

What are the adjustment ranges for the dials on an ATS01N2..LU/QN/RT?

For both the START TIME and STOP TIME dials, setpoint A is 1second and setpoint E is 10seconds.  There is a linear relationship from A to E setpoints.
For the INITIAL VOLTAGE dial, setpoint A is 30% and setpoint E is 80% of full voltage.  There is a linear relationship from A to E setpoints.
 
Show More