Quantcast

Msc Chassis for 12P of 27mm &48P of 18mm

Msc Chassis for 12P of 27mm &48P of 18mm

Msc Chassis for 12P of 27mm &48P of 18mm

Item Number: CH25603

Retail
$1,240.18
RRP (Inc. GST)

Datasheet

Specifications

Design

Range

Acti 9

Product or component type

chassis

Device application

distribution

Physical

Range compatibility

Acti 9 Isobar B distribution board

[In] rated current

250 A

Number of poles

  • 12 27 mm
  • 48 18 mm
    • Length

      596 mm

      Width

      215 mm

      EU RoHS Directive

      Pro-active compliance (Product out of EU RoHS legal scope)

      China RoHS Regulation

      Product out of China RoHS scope. Substance declaration for your information

      Others

      Package 1 Height

      97 mm

      Package 1 Length

      242 mm

      Package 1 width

      885 mm

      Device short name

      MSC 18/27

      Short-circuit withstand

      25 kA 0.1 s

      [Icw] rated short-time withstand current

      25 kA

      Number of ways

    • 1 way (incomer) - 3P
    • 60 ways (outgoer)
      • Package 1 Weight

        4957.5 g
        Show all specifications

        Documents & downloads

        hide show
        Filter items
        • All

        • Technical Data Catalogues

        • Specifications

        Frequently Asked Questions

        hide show

        What is the PAN assembly for C120 MCCB's

         The part code is C125123

        How many 3 pole C120 breakers can be supplied from the C125123?

        That is a 3 phase, 12 pole supply with 27mm spcaing. It will supply up to 4x 3 pole breakers.

        Can you change the trip settings on a Micrologic trip unit with the breaker energized?

        Product Line:
        Circuit Breakers

        Environment:
        Electrical Distribution Equipment

        Resolution:
        We do not recommend doing making changes to trip unit while energized. We can not guarantee that the breaker will not trip and there are safety concerns working on energized equipment.
         

        Is it possible to see the fault current and fault type after tripping in Compact NSX with Micrologic 5 and Micrologic 6.

        Yes, it is possible to see the fault current and fault type after tripping in Compact NSX with Micrologic 5 and Micrologic 6. The external 24V DC must be provided to Micrologics. After Fault trip, the type of fault (Ir, Isd, Ii, Ig), the phase concerned and the interrupted current will be displayed by the Micrologic 5 and 6.

        What is Remote Area Network ( RAN )

        Remote Area Network or RAN was a network method that enabled wireless transfer of data via landline, RS232 serial port, cell phone or satellite connections. The Symax 8030 CRM 560 was a Remote Network Interface Module that used this method of linking IO from field devices to local area and remote area networks. The RAN methodlogy is the basis for transmitting data via radio modems.