MSC Chassis for 12P of 27mm &48P of 18mm
CH25603
MSC Chassis for 12P of 27mm &48P of 18mm
CH25603

Msc Chassis for 12P of 27mm &48P of 18mm

Catalogue Number: CH25603
MSC Chassis for 12P of 27mm &48P of 18mm
CH25603
MSC Chassis for 12P of 27mm &48P of 18mm
CH25603
Retail
$1,240.18
RRP (Inc. GST)

Specifications

hide show
Range
Acti 9
Device short name
MSC 18/27
Product or component type
chassis
Device application
distribution
Range compatibility
Acti 9 Isobar B distribution board
[In] rated current
250 A
Short-circuit withstand
25 kA 0.1 s
[Icw] rated short-time withstand current
25 kA
Number of ways
  • 1 way (incomer) - 3P
  • 60 ways (outgoer)
    • Number of poles
    • 12 27 mm
    • 48 18 mm
      • Length
        596 mm
        Width
        215 mm
        Package 1 Weight
        4957.5 g
        Package 1 Height
        97 mm
        Package 1 width
        885 mm
        Package 1 Length
        242 mm
        EU RoHS Directive
        Pro-active compliance (Product out of EU RoHS legal scope)
        China RoHS Regulation
        Product out of China RoHS scope. Substance declaration for your information

        Documents & downloads

        hide show
        Filter items
        • All

        • Technical Data Catalogues

        • Specifications

        Frequently Asked Questions

        hide show

        What distribution board is required for the CH25843 chassis?

        For the customized distribution board for 72 pole (18 mm) and 12 pole (27 mm) chassis, you need to submit request for a quote to "au.estimating@schneider-electric.com". Our Standard distribution board only goes up to 60 pole (18 mm) and 12 pole (27 mm).

        What is the PAN assembly for C120 MCCB's

         The part code is C125123

        How many 3 pole C120 breakers can be supplied from the C125123?

        That is a 3 phase, 12 pole supply with 27mm spcaing. It will supply up to 4x 3 pole breakers.

        Can you change the trip settings on a Micrologic trip unit with the breaker energized?

        Product Line:
        Circuit Breakers

        Environment:
        Electrical Distribution Equipment

        Resolution:
        We do not recommend doing making changes to trip unit while energized. We can not guarantee that the breaker will not trip and there are safety concerns working on energized equipment.
         

        Is it possible to see the fault current and fault type after tripping in Compact NSX with Micrologic 5 and Micrologic 6.

        Yes, it is possible to see the fault current and fault type after tripping in Compact NSX with Micrologic 5 and Micrologic 6. The external 24V DC must be provided to Micrologics. After Fault trip, the type of fault (Ir, Isd, Ii, Ig), the phase concerned and the interrupted current will be displayed by the Micrologic 5 and 6.