Frequently Asked Questions
hide
show
What distribution board is required for the CH25843 chassis?
For the customized distribution board for 72 pole (18 mm) and 12 pole (27 mm) chassis, you need to submit request for a quote to "au.estimating@schneider-electric.com". Our Standard distribution board only goes up to 60 pole (18 mm) and 12 pole (27 mm).
What is the PAN assembly for C120 MCCB's
The part code is C125123
How many 3 pole C120 breakers can be supplied from the C125123?
That is a 3 phase, 12 pole supply with 27mm spcaing. It will supply up to 4x 3 pole breakers.
What is the meaning of "PLC Returned error code 02H" for Magelis Targets HMIGTO ?
The error "PLC Returned error code 02H", means that you are trying to access an address in the slave device which is not defined or inaccessible or there can be issue with communication card , cable, or communication settings done inside IOmanager communication equipment channels must be checked. Mostly the issue observed is related to register mismatch between target and slave device. Correcting this will resolve the issues.
Can I add programmable contacts to a Powerpact P or R frame breaker in the field?
Product Line:
Circuit Breakers
PowerPact P and R
Micrologic Trip Units
Environment:
Electrical Distribution Equipment
Resolution:
Yes. An externally mounted field installable M2C kit for Powerpact P and R breakers is available. Cat #: S64273
NOTE: You need a ``P`` or ``H`` trip unit to use this module, or an ``A`` trip unit with the BCM installed. BCM part number is S64205
What are the coil voltage codes for the LC1D09 / LC2D09 through LC1D38 / LC2D38 TeSys contactors?
Issue:
Coil Voltage suffixes for Tesys D contactors LC*D 09/38
Product Line:
IEC Contactors and Starters
Environment:
Tesys D contactors
Cause:
Selection
Resolution:
The following lists the more common voltage suffix codes for these product lines. For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.
AC Volts ___Code AC Volts ___Code
12 ___ J7 208 ___ LE7
21 ___ Z7 220 ___ M7
24 ___ B7 230 ___ P7
32 ___ C7 240 ___ U7
36 ___ CC7 277 ___ W7
42 ___ D7 380 ___ Q7
48 ___ E7 400 ___ V7
60 ___ EE7 415 ___ N7
100 ___ K7 440 ___ R7
110 ___ F7 480 ___ T7
115 ___ FE7 575 ___ SC7
120 ___ G7 600 ___ X7
127 ___ FC7 690 ___ Y7
200 ___ L7
Standard Coil Low Consumption
DC Volts ___Code DC Volts ___Code
12 ___ JD 5 ___ AL
24 ___ BD 12 ___ JL
36 ___ CD 20 ___ ZL
48 ___ ED 24 ___ BL
60 ___ ND 48 ___ EL
72 ___ SD 72 ___ SL
110 ___ FD 96 ___ DL
125 ___ GD 110 ___ FL
220 ___ MD 220 ___ ML
250 ___ UD 250 ___ UL
440 ___ RD
Show More