TeSys D Control Relay, 3 NO + 2 NC, <= 690V, 72VDC, Low Consumption Coil

TeSys D Control Relay, 3 NO + 2 NC, <= 690V, 72VDC, Low Consumption Coil

TeSys D Control Relay, 3 NO + 2 NC, <= 690V, 72VDC, Low Consumption Coil

Item Number: CAD32SL

Retail
$520.18
RRP (Inc. GST)

Product Dimensions

Width icon

Width45 mm

Height icon

Height77 mm

Depth icon

Depth93 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D control relay

Range

TeSys

Product or component type

control relay

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[Ue] rated operational voltage

<= 690 V AC 25...400 Hz

Mounting support

  • plate
  • rail
    • Connections - terminals

    • screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
    • screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
    • screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
    • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
    • screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
    • screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
      • Mechanical durability

        30 Mcycles

        Insulation resistance

        > 10 MOhm

        Height

        77 mm

        Width

        45 mm

        Depth

        93 mm

        Net weight

        0.58 kg

        Standards

      • BS 4794
      • EN 60947-5
      • IEC 60947-5-1
      • NF C 63-140
      • VDE 0660
        • Product certifications

        • UL
        • CSA
          • IP degree of protection

            IP2x conforming to VDE 0106

            Ambient air temperature for storage

            -60-80 °C

            EU RoHS Directive

            Compliant

            Mercury free

            Yes

            RoHS exemption information

            Yes

            China RoHS Regulation

            Product out of China RoHS scope. Substance declaration for your information

            Environmental Disclosure

            ENVPEP110230EN

            Circularity Profile

            ENVEOLI1102030EN

            California proposition 65

            WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov

            Others

            Product name

            TeSys CAD

            Device short name

            CAD

            Contactor application

            control circuit

            Utilisation category

          • AC-14
          • DC-13
          • AC-15
            • Pole contact composition

              3 NO + 2 NC

              Control circuit type

              DC low consumption

              [Uc] control circuit voltage

              72 V DC

              [Uimp] rated impulse withstand voltage

              6 kV conforming to IEC 60947

              [Ith] conventional free air thermal current

              10 A (at 60 °C)

              Irms rated making capacity

            • 140 A AC conforming to IEC 60947-5-1
            • 250 A DC conforming to IEC 60947-5-1
              • [Icw] rated short-time withstand current

              • 100 A - 1 s
              • 120 A - 500 ms
              • 140 A - 100 ms
                • Associated fuse rating

                  10 A gG conforming to IEC 60947-5-1

                  [Ui] rated insulation voltage

                • 600 V UL certified
                • 600 V CSA certified
                • 690 V conforming to IEC 60947-5-1
                  • Tightening torque

                  • 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
                  • 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                    • Operating time

                    • 65...88 ms coil energisation and NO closing
                    • 14...25 ms coil de-energisation and NO opening
                    • 57...77 ms coil energisation and NC opening
                    • 28...42 ms coil de-energisation and NC closing
                      • Maximum operating rate

                        180 cyc/mn

                        Time constant

                        40 ms

                        Inrush power in W

                        2.4-2.4 W (at 20 °C)

                        Hold-in power consumption in W

                        2.4-2.4 W at 20 °C

                        Minimum switching voltage

                        17 V

                        Minimum switching current

                        5 mA

                        Non-overlap time

                      • 1.5 ms on energisation between NC and NO contact
                      • 1.5 ms on de-energisation between NC and NO contact
                        • Mechanical robustness

                        • shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27
                        • shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
                        • vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
                        • vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
                          • Compatibility code

                            CAD

                            Protective treatment

                            TH conforming to IEC 60068

                            Operating altitude

                            3000 m without derating

                            Unit Type of Package 1

                            PCE

                            Number of Units in Package 1

                            1

                            Package 1 Weight

                            424 g

                            Package 1 Height

                            4.9 cm

                            Package 1 width

                            11.1 cm

                            Package 1 Length

                            8.9 cm

                            WEEE

                            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                            Show all specifications

                            Frequently Asked Questions

                            hide show

                            Are replacement contacts available for a CAD32 relay?

                            Issue:
                            Contacts need to be replaced in a CAD32** relay.

                            Product Line:
                            TeSys D IEC style relays

                            Environment:
                            CAD relays

                            Resolution:
                            The TeSys D IEC style relays do not offer replacement parts.  Replace entire device.

                            What is the replacement for a CA3KN313BD needed

                             Use a CAD32BD

                            What the DC current contact ratings for the CAD50, CAD32, CAD503, CAD323, CAD506, and CAD326 relay?

                            Issue:
                            Checking on the DC current contact ratings for the CAD50, CAD32, CAD503,  CAD323,  CAD506, and  CAD326 relay.

                            Product Line:
                            CAD Industrial Relays

                            Environment:
                            Relays and Timers

                            Resolution:
                            Inductive:
                            125V DC - 0.55 Amps make and break, 2.5 Amps cont.
                            250V DC - 0.27 Amps make and break, 2.5 amps cont.
                            600V DC - 0.10 Amps make and break, 2.5 Amps cont.

                             

                            Will the LA4DC1U work with the new CAD32BD relay?

                            Issue:
                            Will the LA4DC1U work on the CAd32BD relay

                            Product Line:
                            IEC relays and accessories

                            Environment:
                            Products sold and used in the United States

                            Cause:
                            Identifying product compatibility

                            Resolution:
                            The CAD32BD with DC coil has built-in coil suppression protection as standard so the LA4DC1U is not needed.


                            CTA-ID : 2031917

                            Is the CAD32 Force guided? Are the contacts mechanically linked?

                            Issue:
                            How do the contacts on the CAD32 work

                            Product Line:
                            Relays and Timers

                            Environment:
                            North American Products
                                                              
                            Resolution:                                                                 
                            The CAD32 relays are force guided, and the contacts are mechanically linked.
                             

                            How many normally opened contacts in a CAD32JL?

                            Control Circuit: AC, DC or LC (Low Consumption)
                            Model D Relay 5-Pole (10 Amp)
                            Type: Instantaneous
                            Number of contacts: 5
                            Composition N/O: 3
                            Composition N/C: 2
                            Coil voltages (1)

                            For further information please visit

                            What is the equivalent for CS722E240 Sprecher & Schuh Relay?

                            The equivalent for CS722E240 Sprecher Schuh Relay is a CAD32U7 or LC1D098U7 can be used.

                             

                            What is the replacement for the CA3DK22BD?

                            Issue:
                            What is the replacement for the CA3DK22BD?

                            Product Line:
                            Relays and Timers

                            Environment:
                            Obsolete Products

                            Cause:
                            Legacy Replacement

                            Resolution:
                            The CA3DK is Obsolete. To electrically replace it, use a CAD32BD & a LAD6K10B
                             

                            What safety category rating do the CAD TeSys relays meet under IEC EN954-1? Do they have linked contacts?

                            Issue:
                            Safety category listing of CAD TeSys relays

                            Product Line:
                            Relays

                            Environment:
                            TeSys D Relays

                            Resolution:
                            ​The Tesys CAD32** and the CAD50** relays and top mounted adder decks have positively guided or linked contacts.  Therefore the contacts meet IEC EN60947-5-1 and are approved to use in safety systems through category 4.

                            Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

                            Issue:
                            Mounting adaptor for GV2 and LC1D contactor

                            Product Line:
                            Motor Starters and Protectors

                            Environment:
                            TeSys GV Manual Starter and Protectors
                            Tesys D Contactors
                             
                            Resolution:
                            The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

                            Is the coil on CAD50BL polarity sensitive?

                            Issue:
                            Is the coil on CAD50BL polarity sensitive? 
                            Product Line:
                            Industrial Relays
                            Environment:
                            Tesys D IEC Style Relays
                            Cause:
                            Determine if relay will work for a specific application.                                     
                            Resolution:                                                                 
                            Yes, the DC coil is polarity sensitive - A1 is positive and A2 is negative.
                             

                            Does CAD32 come with Cat 3 certification?

                            No it does not.
                            Please refer the below link
                            https://www.dguv.de/ifa/Praxishilfen/Software/SISTEMA/index-2.jsp