Control relay for connection by screw clamp terminal or lug CAD32 or CAD326 with cover
Control relay for connection by screw clamp terminal or lug CAD32 or CAD326 without cover
Control relay for connection by screw clamp terminal or lug CAD32 or CAD326 with cover
Control relay for connection by screw clamp terminal or lug CAD32 or CAD326 without cover

TeSys D Control Relay, 3 NO + 2 NC, <= 690V, 12VDC, Low Consumption Coil

Catalogue Number: CAD32JL
Control relay for connection by screw clamp terminal or lug CAD32 or CAD326 with cover
Control relay for connection by screw clamp terminal or lug CAD32 or CAD326 without cover
Control relay for connection by screw clamp terminal or lug CAD32 or CAD326 with cover
Control relay for connection by screw clamp terminal or lug CAD32 or CAD326 without cover
Retail
$520.18
RRP (Inc. GST)

Specifications

hide show
Range of product
TeSys D control relay
Range
TeSys
Product name
TeSys CAD
Product or component type
control relay
Device short name
CAD
Contactor application
control circuit
Utilisation category
  • AC-14
  • AC-15
  • DC-13
    • Pole contact composition
      3 NO + 2 NC
      [Ue] rated operational voltage
      <= 690 V AC 25...400 Hz
      Control circuit type
      DC low consumption
      [Uc] control circuit voltage
      12 V DC
      [Uimp] rated impulse withstand voltage
      6 kV conforming to IEC 60947
      [Ith] conventional free air thermal current
      10 A (at 60 °C)
      Irms rated making capacity
    • 140 A AC conforming to IEC 60947-5-1
    • 250 A DC conforming to IEC 60947-5-1
      • [Icw] rated short-time withstand current
      • 100 A - 1 s
      • 120 A - 500 ms
      • 140 A - 100 ms
        • Associated fuse rating
          10 A gG conforming to IEC 60947-5-1
          [Ui] rated insulation voltage
        • 600 V UL certified
        • 600 V CSA certified
        • 690 V conforming to IEC 60947-5-1
          • Mounting support
          • plate
          • rail
            • Connections - terminals
            • screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
            • screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
            • screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
            • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
            • screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
            • screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
              • Tightening torque
              • 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
              • 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                • Control circuit voltage limits
                • operational: 0.7...1.25 Uc
                • drop-out: 0.1...0.25 Uc
                  • Operating time
                  • 65...88 ms coil energisation and NO closing
                  • 14...25 ms coil de-energisation and NO opening
                  • 57...77 ms coil energisation and NC opening
                  • 28...42 ms coil de-energisation and NC closing
                    • Mechanical durability
                      30 Mcycles
                      Maximum operating rate
                      180 cyc/mn
                      Time constant
                      40 ms
                      Inrush power in W
                      2.4-2.4 W (at 20 °C)
                      Hold-in power consumption in W
                      2.4-2.4 W at 20 °C
                      Minimum switching voltage
                      17 V
                      Minimum switching current
                      5 mA
                      Non-overlap time
                    • 1.5 ms on energisation between NC and NO contact
                    • 1.5 ms on de-energisation between NC and NO contact
                      • Insulation resistance
                        > 10 MOhm
                        Mechanical robustness
                      • shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27
                      • shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
                      • vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
                      • vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
                        • Height
                          77 mm
                          Width
                          45 mm
                          Depth
                          93 mm
                          Net weight
                          0.58 kg
                          Compatibility code
                          CAD
                          Standards
                        • BS 4794
                        • EN 60947-5
                        • IEC 60947-5-1
                        • NF C 63-140
                        • VDE 0660
                          • Product certifications
                          • UL
                          • CSA
                            • IP degree of protection
                              IP2x conforming to VDE 0106
                              Protective treatment
                              TH conforming to IEC 60068
                              Ambient air temperature for operation
                              -40-70 °C
                              Ambient air temperature for storage
                              -60-80 °C
                              Operating altitude
                              3000 m without
                              Sustainable offer status
                              Green Premium product
                              REACh Regulation
                              Free of Substances of Very High Concern above the threshold
                              REACh free of SVHC
                              Yes
                              EU RoHS Directive
                              Compliant
                              Mercury free
                              Yes
                              RoHS exemption information
                              Yes
                              China RoHS Regulation
                              Product out of China RoHS scope. Substance declaration for your information
                              Environmental Disclosure
                              ENVPEP110230EN
                              Circularity Profile
                              ENVEOLI1102030EN
                              WEEE
                              The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                              Warranty
                              18 months

                              Frequently Asked Questions

                              hide show

                              Are replacement contacts available for a CAD32 relay?

                              Issue:
                              Contacts need to be replaced in a CAD32** relay.

                              Product Line:
                              TeSys D IEC style relays

                              Environment:
                              CAD relays

                              Resolution:
                              The TeSys D IEC style relays do not offer replacement parts.  Replace entire device.

                              How many normally opened contacts in a CAD32JL?

                              Control Circuit: AC, DC or LC (Low Consumption)
                              Model D Relay 5-Pole (10 Amp)
                              Type: Instantaneous
                              Number of contacts: 5
                              Composition N/O: 3
                              Composition N/C: 2
                              Coil voltages (1)

                              For further information please visit

                              What is the replacement for a CA3KN313BD needed

                               Use a CAD32BD

                              What the DC current contact ratings for the CAD50, CAD32, CAD503, CAD323, CAD506, and CAD326 relay?

                              Issue:
                              Checking on the DC current contact ratings for the CAD50, CAD32, CAD503,  CAD323,  CAD506, and  CAD326 relay.

                              Product Line:
                              CAD Industrial Relays

                              Environment:
                              Relays and Timers

                              Resolution:
                              Inductive:
                              125V DC - 0.55 Amps make and break, 2.5 Amps cont.
                              250V DC - 0.27 Amps make and break, 2.5 amps cont.
                              600V DC - 0.10 Amps make and break, 2.5 Amps cont.

                               

                              Will the LA4DC1U work with the new CAD32BD relay?

                              Issue:
                              Will the LA4DC1U work on the CAd32BD relay

                              Product Line:
                              IEC relays and accessories

                              Environment:
                              Products sold and used in the United States

                              Cause:
                              Identifying product compatibility

                              Resolution:
                              The CAD32BD with DC coil has built-in coil suppression protection as standard so the LA4DC1U is not needed.


                              CTA-ID : 2031917

                              Is the CAD32 Force guided? Are the contacts mechanically linked?

                              Issue:
                              How do the contacts on the CAD32 work

                              Product Line:
                              Relays and Timers

                              Environment:
                              North American Products
                                                                
                              Resolution:                                                                 
                              The CAD32 relays are force guided, and the contacts are mechanically linked.
                               

                              What is the equivalent for CS722E240 Sprecher & Schuh Relay?

                              The equivalent for CS722E240 Sprecher Schuh Relay is a CAD32U7 or LC1D098U7 can be used.

                               

                              What is the replacement for the CA3DK22BD?

                              Issue:
                              What is the replacement for the CA3DK22BD?

                              Product Line:
                              Relays and Timers

                              Environment:
                              Obsolete Products

                              Cause:
                              Legacy Replacement

                              Resolution:
                              The CA3DK is Obsolete. To electrically replace it, use a CAD32BD & a LAD6K10B
                               

                              What safety category rating do the CAD TeSys relays meet under IEC EN954-1? Do they have linked contacts?

                              Issue:
                              Safety category listing of CAD TeSys relays

                              Product Line:
                              Relays

                              Environment:
                              TeSys D Relays

                              Resolution:
                              ​The Tesys CAD32** and the CAD50** relays and top mounted adder decks have positively guided or linked contacts.  Therefore the contacts meet IEC EN60947-5-1 and are approved to use in safety systems through category 4.

                              Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

                              Issue:
                              Mounting adaptor for GV2 and LC1D contactor

                              Product Line:
                              Motor Starters and Protectors

                              Environment:
                              TeSys GV Manual Starter and Protectors
                              Tesys D Contactors
                               
                              Resolution:
                              The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

                              Is the coil on CAD50BL polarity sensitive?

                              Issue:
                              Is the coil on CAD50BL polarity sensitive? 
                              Product Line:
                              Industrial Relays
                              Environment:
                              Tesys D IEC Style Relays
                              Cause:
                              Determine if relay will work for a specific application.                                     
                              Resolution:                                                                 
                              Yes, the DC coil is polarity sensitive - A1 is positive and A2 is negative.
                               

                              Does CAD32 come with Cat 3 certification?

                              No it does not.
                              Please refer the below link
                              https://www.dguv.de/ifa/Praxishilfen/Software/SISTEMA/index-2.jsp
                              Show More