Control relay for connection by screw clamp terminal or lug CAD32 or CAD326 with cover
Control relay for connection by screw clamp terminal or lug CAD32 or CAD326 without cover
Control relay for connection by screw clamp terminal or lug CAD32 or CAD326 with cover
Control relay for connection by screw clamp terminal or lug CAD32 or CAD326 without cover

TeSys D Control Relay, 3 NO + 2 NC, <= 690V, 96VDC, Standard Coil

Catalogue Number: CAD32DD
Control relay for connection by screw clamp terminal or lug CAD32 or CAD326 with cover
Control relay for connection by screw clamp terminal or lug CAD32 or CAD326 without cover
Control relay for connection by screw clamp terminal or lug CAD32 or CAD326 with cover
Control relay for connection by screw clamp terminal or lug CAD32 or CAD326 without cover
Retail
N/A
RRP (Inc. GST)

Specifications

hide show
Range of product
TeSys D control relay
Range
TeSys
Product name
TeSys CAD
Product or component type
control relay
Device short name
CAD
Contactor application
control circuit
Utilisation category
  • AC-14
  • AC-15
  • DC-13
    • Pole contact composition
      3 NO + 2 NC
      [Ue] rated operational voltage
      <= 690 V AC 25...400 Hz
      Control circuit type
      DC standard
      [Uc] control circuit voltage
      96 V DC
      [Uimp] rated impulse withstand voltage
      6 kV conforming to IEC 60947
      [Ith] conventional free air thermal current
      10 A (at 60 °C)
      Irms rated making capacity
    • 140 A AC conforming to IEC 60947-5-1
    • 250 A DC conforming to IEC 60947-5-1
      • [Icw] rated short-time withstand current
      • 100 A - 1 s
      • 120 A - 500 ms
      • 140 A - 100 ms
        • Associated fuse rating
          10 A gG conforming to IEC 60947-5-1
          [Ui] rated insulation voltage
        • 600 V UL certified
        • 600 V CSA certified
        • 690 V conforming to IEC 60947-5-1
          • Mounting support
          • plate
          • rail
            • Connections - terminals
            • screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
            • screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
            • screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
            • screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
            • screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
            • screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
              • Tightening torque
              • 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
              • 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                • Operating time
                • 53...72 ms coil energisation and NO closing
                • 16...24 ms coil de-energisation and NO opening
                • 47...63 ms coil energisation and NC opening
                • 15...25 ms coil de-energisation and NC closing
                  • Mechanical durability
                    30 Mcycles
                    Maximum operating rate
                    180 cyc/mn
                    Time constant
                    28 ms
                    Inrush power in W
                    5.4-5.4 W (at 20 °C)
                    Hold-in power consumption in W
                    5.4-5.4 W at 20 °C
                    Minimum switching voltage
                    17 V
                    Minimum switching current
                    5 mA
                    Non-overlap time
                  • 1.5 ms on energisation between NC and NO contact
                  • 1.5 ms on de-energisation between NC and NO contact
                    • Insulation resistance
                      > 10 MOhm
                      Mechanical robustness
                    • shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27
                    • shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
                    • vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
                    • vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
                      • Height
                        77 mm
                        Width
                        45 mm
                        Depth
                        93 mm
                        Net weight
                        0.58 kg
                        Compatibility code
                        CAD
                        Standards
                      • BS 4794
                      • EN 60947-5
                      • IEC 60947-5-1
                      • NF C 63-140
                      • VDE 0660
                        • Product certifications
                        • CSA
                        • UL
                          • IP degree of protection
                            IP2x front face conforming to VDE 0106
                            Protective treatment
                            TH conforming to IEC 60068
                            Ambient air temperature for storage
                            -60-80 °C
                            Operating altitude
                            3000 m without derating
                            Package 1 Weight
                            0.392 kg
                            Package 1 Height
                            0.49 dm
                            Package 1 width
                            1.11 dm
                            Package 1 Length
                            0.89 dm
                            Sustainable offer status
                            Green Premium product
                            EU RoHS Directive
                            Compliant
                            Mercury free
                            Yes
                            RoHS exemption information
                            Yes
                            China RoHS Regulation
                            Product out of China RoHS scope. Substance declaration for your information
                            Environmental Disclosure
                            ENVPEP110230EN
                            Circularity Profile
                            ENVEOLI1102030EN
                            WEEE
                            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                            California proposition 65
                            WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
                            Warranty
                            18 months

                            Frequently Asked Questions

                            hide show

                            Are replacement contacts available for a CAD32 relay?

                            Issue:
                            Contacts need to be replaced in a CAD32** relay.

                            Product Line:
                            TeSys D IEC style relays

                            Environment:
                            CAD relays

                            Resolution:
                            The TeSys D IEC style relays do not offer replacement parts.  Replace entire device.

                            What is the replacement for a CA3KN313BD needed

                             Use a CAD32BD

                            Will the LA4DC1U work with the new CAD32BD relay?

                            Issue:
                            Will the LA4DC1U work on the CAd32BD relay

                            Product Line:
                            IEC relays and accessories

                            Environment:
                            Products sold and used in the United States

                            Cause:
                            Identifying product compatibility

                            Resolution:
                            The CAD32BD with DC coil has built-in coil suppression protection as standard so the LA4DC1U is not needed.


                            CTA-ID : 2031917

                            What the DC current contact ratings for the CAD50, CAD32, CAD503, CAD323, CAD506, and CAD326 relay?

                            Issue:
                            Checking on the DC current contact ratings for the CAD50, CAD32, CAD503,  CAD323,  CAD506, and  CAD326 relay.

                            Product Line:
                            CAD Industrial Relays

                            Environment:
                            Relays and Timers

                            Resolution:
                            Inductive:
                            125V DC - 0.55 Amps make and break, 2.5 Amps cont.
                            250V DC - 0.27 Amps make and break, 2.5 amps cont.
                            600V DC - 0.10 Amps make and break, 2.5 Amps cont.

                             

                            Is the CAD32 Force guided? Are the contacts mechanically linked?

                            Issue:
                            How do the contacts on the CAD32 work

                            Product Line:
                            Relays and Timers

                            Environment:
                            North American Products
                                                              
                            Resolution:                                                                 
                            The CAD32 relays are force guided, and the contacts are mechanically linked.
                             

                            What is the replacement for the CA3DK22BD?

                            Issue:
                            What is the replacement for the CA3DK22BD?

                            Product Line:
                            Relays and Timers

                            Environment:
                            Obsolete Products

                            Cause:
                            Legacy Replacement

                            Resolution:
                            The CA3DK is Obsolete. To electrically replace it, use a CAD32BD & a LAD6K10B
                             

                            What is the equivalent for CS722E240 Sprecher & Schuh Relay?

                            The equivalent for CS722E240 Sprecher Schuh Relay is a CAD32U7 or LC1D098U7 can be used.

                             

                            Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

                            Issue:
                            Mounting adaptor for GV2 and LC1D contactor

                            Product Line:
                            Motor Starters and Protectors

                            Environment:
                            TeSys GV Manual Starter and Protectors
                            Tesys D Contactors
                             
                            Resolution:
                            The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

                            What is the altitude derating for a TeSys D-Line contactor?

                            Issue:​
                            What is the altitude derating for a TeSys D-Line contactor?

                            Product Line:
                            Digest 177 Section 18 : Contactors and Starters, IEC

                            Environment:
                            North American Products

                            Resolution:
                            The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

                            Voltage
                            3500m x 0.90
                            4000m x 0.80
                            4500m x 0.70
                            5000m x 0.60

                            Current
                            3500m x 0.92
                            4000m x 0.90
                            4500m x 0.88
                            5000m x 0.86

                            For example, an LC1D80 at 5000 meters:
                            - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
                            - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



                             

                            Where are the control coil terminals for TeSys LC1D09 to LC1D38 contactor?

                            Issue:
                            Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor

                            Product Line: 
                            Tesys D Contactors

                            Environment:
                            IEC contactors

                            Resolution:
                            The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section).  They are next to the auxiliary contact (13/14, 21/22) terminals.
                             

                            What safety category rating do the CAD TeSys relays meet under IEC EN954-1? Do they have linked contacts?

                            Issue:
                            Safety category listing of CAD TeSys relays

                            Product Line:
                            Relays

                            Environment:
                            TeSys D Relays

                            Resolution:
                            ​The Tesys CAD32** and the CAD50** relays and top mounted adder decks have positively guided or linked contacts.  Therefore the contacts meet IEC EN60947-5-1 and are approved to use in safety systems through category 4.

                            On a TeSys D or TeSys IEC relay, is there a top mounting provision that will allow you to relocate the A1 & A2 terminals from the right side to the top?

                            Issue:
                            On a TeSys D or TeSys IEC relay, is there a top mounting provision that will allow you to relocate the A1 & A2 terminals from the right side to the top?

                            Product Line:
                            TeSys D LC1D09-LC1D65A, TeSys IEC relay CAD**

                            Environment:
                            CAD, LC1D

                            Cause:
                            Assembly/wiring

                            Resolution:
                            The current TeSys IEC D line contactors ( LC1D09-LC1D65A) and the  TeSys IEC  Relay (CAD**) have A1 and A2 Terminals located on the right side of the device. To relocate the A1 & A2 Terminals, consider using the LAD4BB top-mounting wiring accessory.  Please note this device can only be used on the D line contactors or the IEC relays that are provided with AC coils. A mounting accessory for units with a DC coil is not available.
                            Show More