hide show

What is the replacement for relay CA3DN40?

The replacement for relay is a - CAD50FD
User-added image
CAD50FD
TeSys D control relay - 5 NO - <= 690 V - 110 V DC standard coil

For more information see; https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=CAD50FD

Is the voltage code BD3 valid for a CA3DN40 relay?

Issue:
Is the voltage code BD3 valid for a CA3DN40 relay?

Product Line:
Tesys Relays

Environment:
All Products

Cause:
Product selection

Resolution:
No.  The voltage code BD3 is for the CA4D Low Consumption relays only.   A 24 volt DC coil with built in transient suppression is not available on the CA3D relay.    Use the add on LA4DA1E varister style or the LA4DC1U diode style add on transient suppressors on the CA3D relays.
 

What the DC current contact ratings for the CAD50, CAD32, CAD503, CAD323, CAD506, and CAD326 relay?

Issue:
Checking on the DC current contact ratings for the CAD50, CAD32, CAD503,  CAD323,  CAD506, and  CAD326 relay.

Product Line:
CAD Industrial Relays

Environment:
Relays and Timers

Resolution:
Inductive:
125V DC - 0.55 Amps make and break, 2.5 Amps cont.
250V DC - 0.27 Amps make and break, 2.5 amps cont.
600V DC - 0.10 Amps make and break, 2.5 Amps cont.

 

What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

Issue:
Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

Product Line:
Contactors and Starters IEC

Environment:
Tesys D contactors and GV manual starters

Cause:
Spacer required

Resolution:
Compensation plate catalog number GV1F03, requires 2 pieces snap together.

What is the color scheme of the Tesys D-Line contactors?

Issue:
Looking for different color scheme of the Tesys D-Line contactors.

Product Line:
Tesys D Contactors

Environment:
LC1D contactors

Resolution:
Beige and dark gray.
 

What is the replacement AC coil for CAD32 and CAD50 relay?

Issue:
AC coil replacement for CAD32 and CAD50

Product Line:
Relays

Environment:
Tesys CAD Control Relays

Cause:
Product selection

Resolution:
Volt = coil part number
12 = LXD1J7
21 = LXD1Z7
24 = LXD1B7
32 = LXD1C7
36 = LXD1CC7
42 = LXD1D7
48 = LXD1E7
60 = LXD1EE7
100 = LXD1K7
110 = LXD1F7
115 = LXD1FE7
120 = LXD1G7
127 = LXD1FC7
200 = LXD1L7
208 = LXD1LL7
220/230 = LXD1M7
230 595 21 LXD1P7
230/240 = LXD1U7
277 781 30 LXD1W7
380/400 = LXD1Q7
400 = LXD1V7
415 = LXD1N7
440 = LXD1R7
480 = LXD1T7
600 = LXD1X7
690 = LXD1Y7

 

Are the D-Line contactors rated to break DC voltages?

Issue: 
Can the TeSys D line be used to control DC loads? 

Product Line:
Tesys D contactors

Environment:
Products sold and used in the United States
 
Cause:
 DC power circuit
 
Resolution:
 
Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

Devices are suitable but not UL Listed for DC applications.

More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


 

What are the stand alone short circuit current ratings on the LC1D** contactors?

Issue:
Tesys D SCCR

Product Line:
Contactors and Overload Relays

Environment:
TeSys™ D Contactors and Overload Relays
 
Resolution:
The contactors have a stand alone withstand rating that has been established by UL and is based on the maximum horsepower rating for a given device. However, only combination type starters are supplied with short circuit protective devices having a short circuit current rating.

They are as follows:
Horsepower SCCR (A)

0 thru 1 1,000
1 thru 50 5,000
51 thru 200 10,000
201 thru 400 18,000
401 thru 600 30,000
601 thru 900 42,000
901 thru 1600 85,000
1601+ 100,000

What are the coil voltage codes for the LC1D09 / LC2D09 through LC1D38 / LC2D38 TeSys contactors?

Issue:
What are the coil voltage codes for the LC1D09 / LC2D09through LC1D38 / LC2D38 TeSys contactors?

Product Line:
IEC Contactors

Environment:
Ordering

Cause:
Selection

Resolution:
The following lists the more common voltage suffix codes for these product lines.  For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.

AC Volts ___Code     AC Volts ___Code
12 ___ J7                   208 ___ LE7
21 ___ Z7                   220 ___ M7
24 ___ B7                  230 ___ P7
32 ___ C7                  240 ___ U7
36 ___ CC7               277 ___ W7
42 ___ D7                  380 ___ Q7
48 ___ E7                   400 ___ V7
60 ___ EE7                415 ___ N7
100 ___ K7                440 ___ R7
110 ___ F7                480 ___ T7
115 ___ FE7              575 ___ SC7
120 ___ G7                600 ___ X7
127 ___ FC7              690 ___ Y7
200 ___ L7                
               
Standard Coil                Low Consumption
DC Volts ___Code          DC Volts ___Code
12 ___ JD                           5 ___ AL
24 ___ BD                         12 ___ JL
36 ___ CD                         20 ___ ZL
48 ___ ED                         24 ___ BL
60 ___ ND                         48 ___ EL
72 ___ SD                         72 ___ SL
110 ___ FD                       96 ___ DL
125 ___ GD                     110 ___ FL
220 ___ MD                    220 ___ ML
250 ___ UD                     250 ___ UL
440 ___ RD                

Video: What auxiliary contact modules are available for the LC1D and LC2D contactors?

Issue:
Auxiliary contact modules for the LC1D and LC2D contactors

Product Line: 
Contactor and Starters - IEC

Environment:
North American Products

Resolution:
Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
Front Mounting; maximum of 1 block per contactor:

N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------1---------LADN11-----------LA1DN11
--1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
--1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
--2-----------0---------LADN20-----------LA1DN20
--2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
--2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
--0-----------2---------LADN02-----------LA1DN02
--2-----------2---------LADN22-----------LA1DN22
--2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
--2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
--2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
--3-----------1---------LADN31------------LA1DN31
--3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
--1-----------3---------LADN13------------LA1DN13
--4-----------0---------LADN40------------LA1DN40
--4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
--0-----------4---------LADN04------------LA1DN04




Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.

N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------0--------LADN10----------LA1DN10
--0-----------1--------LADN01----------LA1DN01

Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
(*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.

N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------1--------LAD8N11----------LA8DN11
--2-----------0--------LAD8N20----------LA8DN20
--0-----------2--------LAD8N02----------N/A

Footnotes:
{1} EN50 012 Machine Tool Terminal Markings
{2} (2) NO Sealed Dust Tight Contacts
{3} Gold Flash Contacts
{4} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
{5} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
{6} (2) NO Dust Tight Contacts & (2) NO Standard Contacts