Quantcast

Chassis C60 2Ph 250A 32P

Datasheet

Specifications

Design

Range

Acti 9

Product or component type

chassis

Device application

distribution

Physical

Range compatibility

Acti 9 Isobar A distribution board

[In] rated current

250 A

Number of poles

32 18 mm

Width

215 mm

Length

290 mm

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Others

Device short name

MSC DC

[Icw] rated short-time withstand current

25 kA

Short-circuit withstand

25 kA 0.1 s

Number of ways

  • 1 way (incomer) - 2P
  • 32 ways (outgoer)
    • Busbar pitch

      18 mm

      Package 1 Weight

      4.899 kg
      Show all specifications

      Documents & downloads

      hide show
      Filter items
      • All

      • Technical Data Catalogues

      • Specifications

      Frequently Asked Questions

      hide show

      What is the replacement AC coil for CAD32 and CAD50 relay?

      Issue:
      AC coil replacement for CAD32 and CAD50

      Product Line:
      Relays

      Environment:
      Tesys CAD Control Relays

      Cause:
      Product selection

      Resolution:
      Volt = coil part number
      12 = LXD1J7
      21 = LXD1Z7
      24 = LXD1B7
      32 = LXD1C7
      36 = LXD1CC7
      42 = LXD1D7
      48 = LXD1E7
      60 = LXD1EE7
      100 = LXD1K7
      110 = LXD1F7
      115 = LXD1FE7
      120 = LXD1G7
      127 = LXD1FC7
      200 = LXD1L7
      208 = LXD1LL7
      220/230 = LXD1M7
      230 595 21 LXD1P7
      230/240 = LXD1U7
      277 781 30 LXD1W7
      380/400 = LXD1Q7
      400 = LXD1V7
      415 = LXD1N7
      440 = LXD1R7
      480 = LXD1T7
      600 = LXD1X7
      690 = LXD1Y7

       

      What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

      Issue:
      Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

      Product Line:
      Contactors and Starters IEC

      Environment:
      Tesys D contactors and GV manual starters

      Cause:
      Spacer required

      Resolution:
      Compensation plate catalog number GV1F03, requires 2 pieces snap together.

      What is the coil burden for the standard DC control coil for the LC*D09__ through LC*D38__ TeSys contactors?

      Issue:
      LC*D09-38 coil consumption

      Product Line:
      Contactors and Overload Relays

      Environment:
      TeSys™ D Contactors and Overload Relays

      Resolution:
      The standard DC coil is 5.4 watts of consumption.

      What is the color scheme of the Tesys D-Line contactors?

      Issue:
      Looking for different color scheme of the Tesys D-Line contactors.

      Product Line:
      Tesys D Contactors

      Environment:
      LC1D contactors

      Resolution:
      Beige and dark gray.
       

      Are the D-Line contactors rated to break DC voltages?

      Issue: 
      Can the TeSys D line be used to control DC loads? 

      Product Line:
      Tesys D contactors

      Environment:
      Products sold and used in the United States
       
      Cause:
       DC power circuit
       
      Resolution:
       
      Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

      Devices are suitable but not UL Listed for DC applications.

      More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


       

      What are the stand alone short circuit current ratings on the LC1D** contactors?

      Issue:
      Tesys D SCCR

      Product Line:
      Contactors and Overload Relays

      Environment:
      TeSys™ D Contactors and Overload Relays
       
      Resolution:
      The contactors have a stand alone withstand rating that has been established by UL and is based on the maximum horsepower rating for a given device. However, only combination type starters are supplied with short circuit protective devices having a short circuit current rating.

      They are as follows:
      Horsepower SCCR (A)

      0 thru 1 1,000
      1 thru 50 5,000
      51 thru 200 10,000
      201 thru 400 18,000
      401 thru 600 30,000
      601 thru 900 42,000
      901 thru 1600 85,000
      1601+ 100,000
      Show More