Chassis C60 Ph+N 24P

Specifications

Design

Product brand

Clipsal

Physical

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Others

Package 1 Weight

1 g
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Technical Data Catalogues

  • Specifications

Frequently Asked Questions

hide show

Where can I find the information on the Status Register for the Quantum 140ATI03000 Thermocouple module?

Attached is the information on the Status Register for the Quantum 140ATI03000 Thermocouple module.

What is the part number for a Brass cover for the Classic double GPO?

The part number for a Brass cover for the Classic double GPO is - C2025C-BS

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=C2025C
User-added image

What is the pin assignment of the RS485 port (COM2) of Magelis XBTGT6330?

The pin assignment if the RJ45 RS485 port, COM2, on Magelis XBTGT6330 is as follows.

1 - Not connected
2 - Not connected
3 - Not conected
4 - D1 output/input , Transfer data RS485
5 - D2 output/input , Transfer data RS485
6 - RTS , output , Request to send
7 - Not connected
8 - SG , Signal ground

See attached file for more details.

 

How to program the ATV71 drive to run from local control (keypad)?

Issue:
How to program ATV71 to run from local control? 

Product Line:
Altivar 71, ATV71

Environment:
All

Cause:
N/A

Resolution:
Select the Drive menu.
Go to 1.6 Command, menu.
Set Ref 1 channel to HMI.
Set Profile to Not Separate.

Where can I find a instruction bulletin or data sheet on the VZ3V1206, VZ3V1207, VZ3V1208 and VZ3V1211 cooling fan kits?

Issue:
Instruction bulletin or data sheet for VZ3V1206, VZ3V1207, VZ3V1208 and VZ3V1211 cooling fan kits?

Product Line:
Altivar ATV61 and ATV61 size 6 thru size 8

Environment:
All

Cause:
Needs a data sheet on the Altivar drives cooling fans for size 6 thru size 8 drives.

Resolution:
See the attached bulletin 30072-452-10

 

Will the Default StatusRegister Setting of 1100 for the PWRMODBUS Driver Work for the Power Meter 600 (PM6) in PowerLogic SCADA v7.10?

The default StatusRegister setting of 1100 will work with the Power Meter 600 in PowerLogic SCADA, even though 1100 is not defined in the PM6 Register List. If the user reads register 1100 with a generic Modbus register reader, he will receive a value of 32768. While this denotes an undefined value, the register is still readable and therefore, the PM6 I/O device can use this register as verification to come online.
The following is some additional general information about the StatusRegister parameter:
This parameter defines the address of the register that the driver will read to determine whether a device is responding to communication requests. The result of this read is not important; however, it must be a valid register address within the device. This parameter can only be configured for the PWRMODBUS driver.


Keywords: Series 600, PM600, PM620, PM650


Legacy KB System (APS) Data: RESL203061 V1.0, Originally authored by AnVa on 08/06/2010, Last Edited by AnVa on 08/06/2010
Related ranges: PowerLogic SCADA 7.1