switch 1g arch c style s/s

Switch 1 Gang Architrave C Style Stainless Steel

Catalogue Number: C31A
switch 1g arch c style s/s
Retail
$107.54
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE

Specifications

hide show
Range of product
Metal Plate
Product brand
Clipsal
Device presentation
basic element with full cover plate and grid
Switch function
switch
Actuator
rocker
Number of rocker
1
Device mounting
flush
Fixing mode
by screws
Surface treatment
stainless steel
Local signalling
without
Marking
without marking
Package 1 Weight
1 kg
EU RoHS Directive
Under investigation
Environmental Disclosure
ENVPEP120506EN

Frequently Asked Questions

hide show

What is the dimensions for B31A (Stainless Steel) and BB31A (Polished Brass) Architrave Switch ?

The dimensions are:
Length x 90mm
Width x 35mm
Depth x 30mm
Mounting Centres x 70mm

What is the dimensions for a B31A (Stainless Steel) and BB31A (Polished Brass) Architrave Switches ?

The dimensions are:
Length x 140mm
Width x 35mm
Depth x 30mm
Mounting Centres x 125mm

What is the part number for a metal plate, stainless steel, single gang, architrave switch?

The part number is B31A - BK  ( for black mech and bezel )

How can you do reference switching over the network and the start/stop from the terminals on an ATV61/71 drive?

Issue:
How can you  switch between the reference channels when the VFD is controlled from the terminals?

Product Line:
Altivar 61 and Altivar 71

Environment:
All models and serial numbers.

Cause:
The unit is not detecting line voltage on the unit.

Resolution:
Command Menu
Reference 1 Channel - Com Card
Profile - Separate
Command Switching - Channel 1 Active
Command Channel 1 - Terminal
Reference 2 Switching – In Drive Com profile C311 to C315.  In IO profile C301 to C315
Reference 2 Channel – Must be selected

Application function Menu
Reference 1B Switching – In Drive Com profile C311 to C315.  In IO profile C301 to C315
Reference 1B Channel – Must be selected

Example: If Reference 2 switching is set to C311 then a decimal value of 2048 must be written to address 8501 to switch to Reference 2 Channel.

What is the total DC bus capacitance for the ATV960 drive in microfarads?

Issue: 
What is the total DC bus capacitance for the ATV960 drive in microfarads?

Product Line:
ATV960

Environment:
All

Cause:
N/A

Resolution: 
T
he DC capacitance for the ATV660/960 is 10mF per brick.

1p: ATV960C11 ... C16: 10mF
2p: ATV960C20 ... C31: 20mF
3p: ATV960C35 ... C50: 30mF
4p: ATV960C56 ... C63: 40mF
5p; ATV960C71 ... C80: 50mF

What is the catalog number for a 9001Type K Pilot Light for 277 volts?

Issue:
What is the catalog number for a 9001Type K Pilot Light for 277 volts?

Product Line:
Harmony Push Buttons

Environment:
Harmony 30mm

Cause:
Product Selection

Resolution:
The catalog number is 9001KP8 which has a 277 volt AC transformer pilot light, however the colored lens is not supplied with this.
You can get a plastic fresnel lens (A31 is amber, blue - L31, clear - C31, green - G31, red - R31, white - W31 or Yellow Y31),
Plastic domed lens (A9 is amber, blue- L9, clear - C9, green - G9, red - R9, white - W9 or yellow - Y9),
or glass lens (A6 is amber, blue - L6, clear - C6, green - G6, red - R6, white - W6 or yellow - Y6) by inserting the correct suffix.


CTA-ID : 2035975

Why is the LCD display screen blank on a Micrologic Power or Harmonic type trip unit on a Powerpact P frame, R frame, or Masterpact circuit breaker?

Issue:
Why is the display blank on the trip unit?

Product Line:
Powerpact P frame, Powerpact R Frame, Masterpact NT, Masterpact NW

Environment:
Applied to Powerpact and Masterpact breakers with trip units with LCD displays.

Cause:
Need to power display of the trip unit without external power supply.

Resolution:
The LCD display on a Micrologic P or H trip unit will be blank unless the trip unit is energized.  Energization requires one of the following sets of conditions:
  1. The trip unit is energized by an external 24 Vdc applied to terminals F1-F2 (F1 negative-F2 positive)
  2. The trip unit is energized by an FFTK or HHTK test kit
  3. There is at least 100 V between two phases, AND the load reaches approximately 20% of the breaker's rated current.
  • Note that the display will not power up with primary injection testing unless one of the conditions in bullet 1 above is met.
  • Note that Ammeter trip units do not require external power and the display will come on with sufficient current flow alone.
See the following bulletins for more information on these trip units.
 

How can you copy a old ATV31 program into a new ATV312 drive?

Issue:
Can you copy an ATV31 drives program into the new ATV312 drive?

Product Line:
Altivar ATV312, ATV31

Environment:
All

Cause:
Needs to use the old file from his ATV31 and put that program into his new ATV312 drive.

Resolution:
Yes, you can copy the old ATV31 file into the new ATV312 drive.
You will need to set up your new ATV312 to act like a old ATV31 by setting the  ArE parameter to 31E or 31A.
The differences are as follows.
31A has the knob on the face of the old ATV31 drive.
31E does not have the knob only the 4 buttons on the face of the drive.
To copy the old program from the ATV31 into the new ATV312 drive you will need the original ATV31 remote keypad, Powersuite software V2.6 or the Multiloader.

See the attached pdf document for notes.

Can an ATV31 file be converted to an ATV312 file using SoMove software?

Issue:
Can an ATV31 file be converted to an ATV312 file using SoMove software?

Product line:
ATV31, ATV312

Environment:
All models, all serial numbers

Cause:
Need to connect to Blue Hose

Resolution:
It is not possible to transfer a configuration from ATV31 to ATV312 with SoMove software.  You will have to use the multiloader or the old ATV31 keypad to copy an 31 file into the ATV312 drive if you configure the ArE parameter to 31A or 31 E.