bend solid pvc cond 25mm

Telecommunication Conduit Fittings, BEnds - Standard Colour White, 25mm

Catalogue Number: C247/25
bend solid pvc cond 25mm
Retail
$23.02
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE

Specifications

hide show
Product brand
Clipsal
Range of product
Series C247
Material
PVC (polyvinyl chloride)
Diameter
25 mm
Operating angle
90 °
Length
106 mm
Inner radius
64 mm
Standards
AS/NZS 2053
Package 1 Weight
0.057 kg
Package 1 Height
135 mm
Package 1 width
2.5 mm
Package 1 Length
135 mm
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Frequently Asked Questions

hide show

Whati s pitch thread for part number 1245/25?

Pitch thread is 1.5mm

Does the 1240/25 series come with gaskets?

No, they are light duty. Buy the 1240HL25 to obtain a heavy duty lid and gasket , or if gasket is required for retro fit then buy 1240GT
For more information on this product range please visit the Clipsal web site on the link provided
https://www.clipsal.com/Trade/search-results?q=1240

What is the part number for a plug to suit the 240/25?

The part number for a plug to suit the 240/25/3 is a 220/25.
 

Is there an extension ring to suit the 343?

Yes, there is the 93ER and also the 249/12 or 249/25.

What is the thread type on a 1235/25?

The thread type on a 1235/25 is BS - British Standard.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=1235/25 

Could not remove directory \usr\Cfg message when upgrading M241/251 firmware

  • When upgrading using Controller Assistant and USB cable, error message "Could not remove directory \usr\Cfg" is displayed.
  • When upgrading using SD card "Delete "/usr/*" (line 1) returned cleaning error" appears in SCRIPT.log file.

This is because some corrupted files can not be deleted.
To delete these files " Format "/usr" " should be added to SD card script.

In firmwares starting from v4.0.2.52 " Format "/usr" " is added automatically by Controller Assistant when generating SD cards.
 

Unity help incorrectly states that the outputs on the BMXDDI1602 are isolated.

Goals and Symptoms
Unity help incorrectly states that the outputs on the BMXDDI1602 are isolated.

Facts and Change
BMXDDI1602

Causes and Fixes
  • Unity help incorrectly shows that the outputs on the BMXDDI1602 are isolated. 



 
  • The wiring diagram from the user manual correctly shows the outputs as not being isolated. 


 

How to calculate Energy readings from the raw Integer register data on an Energy Meter

Issue
The energy values are stored across two 16-bit integer registers on an energy meter. 

Product Line
Energy Meter

Environment
Reading and converting Modbus register values

Resolution
The Energy Meter stores energy across two 16-bit integer registers.

Register #1 and Register #2 (Modbus address 257/258 for Register #1 and 259/260 for Register #2). Register #2 is the High WORD and Register #1 is the Low WORD. 

The Multiplier/Divisor table states that both of these registers must be divided by 32 to obtain the real value from the raw data.
The Multiplier/Divisor should NOT be applied to both registers. It is applied to the final value of both registers.

To calculate the Energy the registers must first be arranged as the register list states [2] is the High word and [1] is the Low word.

To make [2] the High word it needs to be shifted to the left 16 bits.
To accomplish this multiply the value in [2] by 65,356.
You will then add this value to the value in [1].
The final value will be divided or multiplied by the correct scaling value. Please see the example listed below.

For this example we will assume an Energy Meter with 300 amp CTs. According to the Integer Multiplier/ Divisor table, 300 amp CTs will give a divisor value, (d), of 32 and a multiplier value, (m), of 0.03125.
We will assume the following register values.
Register #1 = 29,586
Register #2 = 31

Using Divisor Table
kWh = ([R2]*65,536+[R1])/d
kWh = (31*65,536+29,586) / 32
kWh = 64412.56

Using Multiplier Table
kWh = ([R2]*65,536+[R1]) * m
kWh = (31*65,536+29,586) * 0.03125
kWh = 64412.56

*Note the divisor will not always be 32 and the multiplier will not always be 0.03125. For the correct values please see the Integer Multiplier Table.
 

SRT 8 or 10kVA reports Error P.11 or DC Bus Soft Start or event codes 124/125

Issue: The UPS reports P.11 or DC Bus Soft Start - event 124/125



Product Line: SRT 8-10kVA Models 

Resolution:
Clear the Alarm. Turn the output ON again. If the problem persists, Brain dead the UPS. If the alarm reoccurs, perform a UPS Firmware upgrade to the latest 04.7 revision that addressed these issues. For complete upgrade instructions please refer to FA164737.
 
Release Notes (UPS 04.7):
========================
1. Improved system performance of transitions between Online and Bypass operation modes.
2. Improved system behaviour for three phase input configurations to reduce transitions to battery under certain input feed conditions.
3. Improved system behaviour to eliminate false detection of DC bus under voltage alarm under certain conditions.
4. Improved system handling for certain AC input conditions during system start-up.