Quantcast

Telecommunication Conduit Fittings, Couplings - Standard Colour White, 32mm

White Electric | Telecommunication Conduit Fittings, Couplings - Standard Colour White, 32mm

Telecommunication Conduit Fittings, Couplings - Standard Colour White, 32mm

Item Number: C242/32-WE

Retail
$7.12
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Range of product

Series C242

Product destination

diameter: 32-32 mm tube

Physical

Length

52-52 mm

Standards

AS/NZS 2053

REACh free of SVHC

Yes

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Material

Material

PVC (polyvinyl chloride)

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

22 g

Package 1 Height

37 mm

Package 1 width

36 mm

Package 1 Length

52 mm
Show all specifications

Frequently Asked Questions

hide show

Can I get the 242/32 in orange?

Yes, the 32mm coupling is available in orange. The part number is 242/32-EO.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=242/32

 

What is the form number to get a 9012 type G preset from the factory?

Issue:
Ordering

Product Line:
Industrial Pressure Switches

Environment:
9012G

Cause:
Preset range and differential settings

Resolution:
Add for Y1 to the catalog number and  include the pressure settings  on the markings section in Quote to Cash in order to process the order. ( ie. 9012GBW2Y1 ( 400 FALL- 435 RISE) )

CTA-ID : 2042032

 

 

Do you have a 32mm inspection Tee conduit fitting with out the inspection hole?

No, unfortunately we only do the 246/32, 32mm, Inspection Tee with the inspection hole.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=246/32

Where are the DC bus connections on a ATV61 drive?

Issue:
Looking for the DC bus connections on a ATV61 Drive.

Product Line:
All ATV61/71 drives

Environment:
All

Cause:
N/A

Resolution:
The DC connections are at PA/+ and PC/-.  Please refer to the installation manual for more information.

Where can I find information on DC bus tying for the ATV71 drives, including wiring diagrams and fuse sizes?

Issue:
DC Bus tying for the ATV71 information, including wiring diagrams and fuses sizes.

Product Line:
Altivar ATV71

Environment:
All

Cause:
Do we have any ATV71 examples of a DC bus tie?

Resolution:
See the attachment for wiring examples and fuse tables for the ATV71 drives DC bus tie.
 

What are possible causes of a web page statistics Overrun fault on an ATV61/71 series drive with Ethernet IP communication card?

Issue:
Possible causes of a web page statistics Overrun fault on an ATV61/71 series drive using Ethernet IP communication card

Product Line:
Altivar 61 / Altivar 71 series drives.

Environment:
All models and serial numbers where Ethernet IP option card, part number VW3A3316, is installed.

Cause:
Information not available in current documentation.

Resolution:

The Overrun counter is a standard Ethernet Diagnostic. The value is provided directly by the Ethernet component used on this card.

The overrun shows the number of times that the receiver hardware was incapable of handing received data to a hardware buffer because the input rate exceeded the receiver's capability to handle the data.

This behavior can be observed when a peak of frames appears on the network.
The origin of the frame peak can be linked to the network load.
Burst of request could be generated on the network when some device restart or Power ON on the same Ethernet network (like for example PC with proxy server). This type of device initialization generates a lot of broadcast frame on the entire network. These frames will be seen by the drive.

A point to check will be to make a network analysis in order to have an idea of the network load.

Then if it appears on only one card:
Dedicated services are launch only on this card.
Even if the protocol selected is Ethernet/IP, the card embeds Modbus TCP server (on webserver for example). These Modbus TCP servers stays accessible. PLC or computer (webserver, specialized tool) could send Modbus TCP request to one card.
So you will have on the same card, CIP implicit exchange + Modbus TCP request. If the rate of those exchanges is really fast, you are in similar condition that burst of request describe before but here only located on one card.
Card could be defective
For this it’s needed to replace the card and send back the card for expertise.


Several verification could be check:
First check the network load
On device where you do not see Overrun fault and on device with Overrun counter increasing. This will give several indications
Compare the Frames load on several drive (one good and the bad one)
Have an overview of all frames send see by this drive with Overrun counter.

Swap 2 card
Take one card where there is no Overrun and swap it with “bad” card.
If issue follow the card, it will be mandatory to analyze this card. But before analyze, we need to have the result of network measurement, and know what are the service used on this card
implicit messaging (what is the speed RPI)
explicit messaging (what frequency)
Modbus TCP exchange used (if yes what is the frequency)
Webserver used or not